Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Vandercook Lake, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 102ft / 31.3mTotal length
  • 103,323Total average daily traffic
  • 8,797Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Vandercook Lake
  • No street view available for this location

New bridges in Vandercook Lake, MI - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 41950-1959
  • 21980-1989
  • 11990-1999
  • 22000-2009
  • 32010-2019
Average Bridge Daily Traffic in Vandercook Lake, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Good
  • 25.0%Satisfactory
  • 12.5%Poor
  • 12.5%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Very good
  • 25.0%Good
  • 37.5%Satisfactory
  • 25.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.5%Very good
  • 37.5%Good
  • 12.5%Satisfactory
  • 37.5%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 57.1%Good
  • 28.6%Satisfactory
  • 14.3%Poor
Find on map >>   Show street view

Structure Number: 4399,  Location: 3.0 MI SE OF JACKSON (Lat: 42.213672,  Lng: -84.374369),  Route carried "on" structure: State highway 50,  Year Built: 2005,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 7,114 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,926 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: GRAND RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.825,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 338,  Subroute: 14),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4442,  Location: @ N JCT M-50 (Lat: 42.205089,  Lng: -84.369497),  Route carried "on" structure: US 127,  Year Built: 1959,  Status: Open,  Structure Length: 8.90m (29.20ft),  Average Daily Traffic: 10,893 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,811 (year 2018),  Design Load: HS 20,  Features Intersected: MDOT RR COR & M-50
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.543,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 89,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 14 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Serious,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 78.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 4443,  Location: @ N JCT M-50 (Lat: 42.205311,  Lng: -84.369603),  Route carried "on" structure: US 127,  Year Built: 1959,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 11,135 (year 2007),  Truck Traffic: 13%,  Average Future Daily Traffic: 9,416 (year 2018),  Design Load: HS 20,  Features Intersected: MDOT RR COR & M-50
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.571,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 89,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 14 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 82.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 4446,  Location: @ S JCT M-50 (Lat: 42.196928,  Lng: -84.369550),  Route carried "on" structure: State highway 50,  Year Built: 2012,  Status: Open,  Structure Length: 6.29m (20.64ft),  Average Daily Traffic: 9,715 (year 2011),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,430 (year 2031),  Design Load: HL 93,  Features Intersected: US-127
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.818,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 89,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4471,  Location: 1 MI W OF VANDERCOOK LAKE (Lat: 42.201406,  Lng: -84.417700),  Route carried "on" structure: County highway 2009,  Year Built: 1937,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 4,916 (year 2005),  Average Future Daily Traffic: 5,500 (year 2019),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: BADGLEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.593,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Poor,  Operating Rating: 63.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4472,  Location: JUST W OF VANDERCOOK LAKE (Lat: 42.198372,  Lng: -84.405225),  Route carried "on" structure: County highway 2009,  Year Built: 1989,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 7,800 (year 2005),  Average Future Daily Traffic: 9,000 (year 2019),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: HINKLEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.027,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 76.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4497,  Location: .5 MI S OF JACKSON (Lat: 42.203367,  Lng: -84.417992),  Route carried "on" structure: County highway 2009,  Year Built: 1984,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 6,000 (year 2001),  Average Future Daily Traffic: 7,300 (year 2017),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: STONEWALL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.246,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 64.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4498,  Location: 1.3 MI S VANDERCOOK LAKE (Lat: 42.177072,  Lng: -84.393556),  Route carried "on" structure: County highway 2009,  Year Built: 2015,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 5,000 (year 2014),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,200 (year 2034),  Design Load: Greater than HL93,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: HAGUE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.613,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.1m (52.8ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4499,  Location: 1 MI N OF VANDERCOOK LAKE (Lat: 42.209350,  Lng: -84.398669),  Route carried "on" structure: County highway 2009,  Year Built: 1993,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 6,700 (year 2004),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,000 (year 2022),  Design Load: HS 25 or greater,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: FRANCIS STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.437,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 18.2m (59.7ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 68.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4529,  Location: 2.6 M N 2 M W CEMENT CITY (Lat: 42.114944,  Lng: -84.373414),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 124 (year 2002),  Average Future Daily Traffic: 200 (year 2022),  Design Load: HS 20,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: GATES ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.949,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4442,  Location: @ N JCT M-50 (Lat: 42.205089,  Lng: -84.369497),  Route carried "under" structure: State highway 50,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 6,070 (year 2007),  Truck Traffic: 6%,  Features Intersected: MDOT RR COR & M-50,  Facility Carried by Structure: US-127 NB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 2.890,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 4443,  Location: @ N JCT M-50 (Lat: 42.205311,  Lng: -84.369603),  Route carried "under" structure: State highway 50,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 6,070 (year 2007),  Truck Traffic: 13%,  Features Intersected: MDOT RR COR & M-50,  Facility Carried by Structure: US-127 SB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 2.865,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 4446,  Location: @ S JCT M-50 (Lat: 42.196928,  Lng: -84.369550),  Route carried "under" structure: US 127,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 21,786 (year 2007),  Truck Traffic: 16%,  Features Intersected: US-127,  Facility Carried by Structure: M-50 (MCDEVITT RD)
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.650,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 32.0m (105.0ft)

Discuss Vandercook Lake, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.