Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Utica, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 92ft / 28.5mTotal length
  • 536,598Total average daily traffic
  • 15,988Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Utica
  • No street view available for this location

New bridges in Utica, MI - historical statistics
  • New bridges - historical statistics
  • 11980-1989
  • 101990-1999
Average Bridge Daily Traffic in Utica, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 83.3%Good
  • 16.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Very good
  • 16.7%Good
  • 33.3%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Very good
  • 50.0%Good
Find on map >>   Show street view

Structure Number: 6014,  Location: M-59 WB OV M-53 (Lat: 42.626211,  Lng: -83.012692),  Route carried "on" structure: State highway 59,  Year Built: 1994,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 43,575 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 48,150 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: M-53
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.487,  Lanes on structure: 5,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 80,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.3m (119.1ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 25.7m (84.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6015,  Location: M-59 EB OV M-53 (Lat: 42.625500,  Lng: -83.012625),  Route carried "on" structure: State highway 59,  Year Built: 1994,  Status: Open,  Structure Length: 7.13m (23.39ft),  Average Daily Traffic: 43,575 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 48,150 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: M-53
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.680,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 82,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.7m (117.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6043,  Location: IN UTICA (Lat: 42.625025,  Lng: -83.037847),  Route carried "on" structure: State highway 59,  Year Built: 1994,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 80,406 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 123,904 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CLINTON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.407,  Lanes on structure: 8,  Base Highway Network: Yes (Inventory Route: 80,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 43.9m (144.0ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 45.6m (149.6ft),  Out-to-Out Width: 47.3m (155.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6044,  Location: IN UTICA (Lat: 42.624983,  Lng: -83.041275),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 8,500 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,775 (year 2008),  Design Load: HS 20,  Features Intersected: M-59,  Facility Carried by Structure: UTICA RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.772,  Lanes on structure: 4,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 16.1m (52.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.7m (77.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6045,  Location: IN UTICA (Lat: 42.624853,  Lng: -83.047133),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 950 (year 1988),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,093 (year 2008),  Design Load: HS 20,  Features Intersected: M-59,  Facility Carried by Structure: MERRILL RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.573,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6433,  Location: WEST OF VAN DYKE (Lat: 42.625825,  Lng: -83.037603),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 3.09m (10.14ft),  Average Daily Traffic: 11,186 (year 2008),  Average Future Daily Traffic: 12,200 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: CLINTON RIVER,  Facility Carried by Structure: AUBURN RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.177,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6014,  Location: M-59 WB OV M-53 (Lat: 42.626211,  Lng: -83.012692),  Route carried "under" structure: State highway 53,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 53,594 (year 2007),  Truck Traffic: 4%,  Features Intersected: M-53,  Facility Carried by Structure: M-59 WB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 9.315,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 36.3m (119.1ft)

Find on map >>   Show street view

Structure Number: 6015,  Location: M-59 EB OV M-53 (Lat: 42.625500,  Lng: -83.012625),  Route carried "under" structure: State highway 53,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 53,594 (year 2007),  Truck Traffic: 4%,  Features Intersected: M-53,  Facility Carried by Structure: M-59 EB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 9.235,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: 6044,  Location: IN UTICA (Lat: 42.624983,  Lng: -83.041275),  Route carried "under" structure: State highway 59,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 80,406 (year 2007),  Truck Traffic: 3%,  Features Intersected: M-59,  Facility Carried by Structure: UTICA RD
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 4.131,  Lanes on structure: 4,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 6045,  Location: IN UTICA (Lat: 42.624853,  Lng: -83.047133),  Route carried "under" structure: State highway 59,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 80,406 (year 2007),  Truck Traffic: 3%,  Features Intersected: M-59,  Facility Carried by Structure: MERRILL RD
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 3.650,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 6046,  Location: IN UTICA (Lat: 42.625133,  Lng: -83.042083),  Route carried "under" structure: State highway 59,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 80,406 (year 2007),  Truck Traffic: 3%,  Features Intersected: M-59,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 5.59m (18.34ft),  Kilometerpoint: 4.064,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Discuss Utica, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.