Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Tuscarora, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 59ft / 18.4mTotal length
  • $761,000Total costs
  • 66,230Total average daily traffic
  • 11,568Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Tuscarora
  • No street view available for this location

New bridges in Tuscarora, PA - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11930-1939
  • 11950-1959
  • 31970-1979
  • 41990-1999
  • 12010-2019
Average Bridge Daily Traffic in Tuscarora, PA
Average Bridge Truck Traffic in Tuscarora, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 42.9%Good
  • 28.6%Satisfactory
  • 28.6%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 42.9%Very good
  • 28.6%Satisfactory
  • 14.3%Fair
  • 14.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 28.6%Good
  • 28.6%Satisfactory
  • 14.3%Fair
  • 14.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 14.3%Very good
  • 28.6%Good
  • 42.9%Fair
  • 14.3%Poor
Find on map >>   Show street view

Structure Number: 3065,  Location: 3200 FT. E.OF SR 1011 (Lat: 40.753094,  Lng: -76.052794),  Route carried "on" structure: US 209,  Year Built: 1976,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 4,088 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 6,749 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB.TO SCHUYLKILL RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.884,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 30651,  Location: 3 MI.E.OF MIDDLEPORT (Lat: 40.760769,  Lng: -76.042081),  Route carried "on" structure: US 209,  Year Built: 1976,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 4,088 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 6,749 (year 2032),  Design Load: HS 20,  Features Intersected: BRANCH SCHUYLKILL RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.782,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 83.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 3075,  Location: VILLAGE OF BROCKTON (Lat: 40.748961,  Lng: -76.063444),  Route carried "on" structure: State highway ,  Year Built: 1976,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 402 (year 2022),  Truck Traffic: 16%,  Average Future Daily Traffic: 442 (year 2032),  Design Load: HS 20,  Features Intersected: SCHUYLKILL RIVER,  Facility Carried by Structure: SR 1011 (LR 53038)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Galvanized Reinforcing
Find on map >>   Show street view

Structure Number: 30752,  Location: 1 M. E. OF LOCUST LAKE (Lat: 40.782847,  Lng: -76.094936),  Route carried "on" structure: State highway ,  Year Built: 1924,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 402 (year 2022),  Truck Traffic: 16%,  Average Future Daily Traffic: 442 (year 2032),  Design Load: HS 20,  Features Intersected: LOCUST CREEK,  Facility Carried by Structure: SR 1011 (LR 53038)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.809,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 6.2m (20.3ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $16,000,  Roadway Improvement Cost: $48,000,  Total Project Cost: $218,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3093,  Location: NW OF TUSCARORA (Lat: 40.790044,  Lng: -76.081403),  Route carried "on" structure: Alternate City street T497,  Year Built: 1935,  Status: Posted for load,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 150 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 165 (year 2020),  Design Load: H 15,  Features Intersected: LOCUST CREEK,  Facility Carried by Structure: CHURCH ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.3m (17.4ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Poor,  Channel: Poor,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.00m (3.28ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: October 2020,  Other Special Inspection Date: October 2021,  Bridge Improvement Cost: $23,000,  Roadway Improvement Cost: $99,000,  Total Project Cost: $305,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 30931,  Location: NW OF TUSCARORA OFF T-497 (Lat: 40.789333,  Lng: -76.066161),  Route carried "on" structure: ServiceCity street ,  Year Built: 1950,  Year Reconstructed: 2006,  Status: Posted for load,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 20 (year 1985),  Average Future Daily Traffic: 100 (year 2030),  Design Load: H 20,  Features Intersected: LOCUST CREEK,  Facility Carried by Structure: RIDGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 4.0m (13.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 23.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.80m (2.62ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2020,  Other Special Inspection Date: April 2021,  Bridge Improvement Cost: $18,000,  Roadway Improvement Cost: $52,000,  Total Project Cost: $238,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 40749,  Location: HAZLE TWP OVER I-81 SB (Lat: 40.750000,  Lng: -76.050000),  Route carried "on" structure: Bypass State highway 424,  Year Built: 1999,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 9,436 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 11,056 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SR 0081 I-81 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.762,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.8m (160.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4075,  Location: HAZLE TWP OVER I-81 NB (Lat: 40.750000,  Lng: -76.050000),  Route carried "on" structure: Bypass State highway 424,  Year Built: 1999,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 9,436 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 11,056 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SR 0081 I-81 NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.762,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.8m (160.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 47111,  Location: 2.4MI N. OF RTE.209 (Lat: 40.793397,  Lng: -76.044667),  Route carried "on" structure: State highway ,  Year Built: 2012,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 829 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,082 (year 2032),  Design Load: HL 93,  Features Intersected: LOCUST CREEK,  Facility Carried by Structure: SR1013 (LR 53036)
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 5.058,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 40749,  Location: HAZLE TWP OVER I-81 SB (Lat: 40.750000,  Lng: -76.050000),  Route carried "under" structure: Interstate 81,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 18,390 (year 2021),  Truck Traffic: 24%,  Features Intersected: SR 0081 I-81 SB,  Facility Carried by Structure: TR 424 BELTWAY
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 2.342,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 48.8m (160.1ft)

Find on map >>   Show street view

Structure Number: 4075,  Location: HAZLE TWP OVER I-81 NB (Lat: 40.750000,  Lng: -76.050000),  Route carried "under" structure: Interstate 81,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 18,989 (year 2021),  Truck Traffic: 22%,  Features Intersected: SR 0081 I-81 NB,  Facility Carried by Structure: TR 424 BELTWAY
Minimum Vertical Clearance: 6.86m (22.51ft),  Kilometerpoint: 2.313,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 48.8m (160.1ft)

Discuss Tuscarora, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.