Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Tamaroa, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 49ft / 14.9mTotal length
  • 3,750Total average daily traffic
  • 458Total average daily truck traffic
  • 3,315Total future (year 2032) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Tamaroa
  • No street view available for this location

New bridges in Tamaroa, IL - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 41980-1989
  • 11990-1999
  • 32000-2009
  • 12010-2019
Average Bridge Truck Traffic in Tamaroa, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 42.9%Very good
  • 14.3%Good
  • 28.6%Satisfactory
  • 14.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 42.9%Very good
  • 14.3%Good
  • 28.6%Satisfactory
  • 14.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 70.0%Very good
  • 10.0%Good
  • 10.0%Satisfactory
  • 10.0%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Very good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 730027,  Location: 1.2 MI E OF US 51 (Lat: 38.082869,  Lng: -89.219636),  Route carried "on" structure: State highway 154,  Year Built: 1985,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 2,800 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 2,163 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: REESE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 73.609,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.0m (39.4ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 733144,  Location: 2.2 MI E OF US 51 (Lat: 38.112389,  Lng: -89.201383),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 300 (year 2019),  Truck Traffic: 20%,  Average Future Daily Traffic: 206 (year 2032),  Design Load: HS 20,  Features Intersected: REESE CREEK,  Facility Carried by Structure: CH 8-KIMZEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.492,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 733152,  Location: 0.5 MI N OF TAMAROA (Lat: 38.150086,  Lng: -89.218261),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 0.83m (2.72ft),  Average Daily Traffic: 75 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 103 (year 2032),  Design Load: HS 20,  Features Intersected: COLLIER CREEK,  Facility Carried by Structure: TR 278
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.612,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.0m (26.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 733172,  Location: 1.9 MI W TAMAROA (Lat: 38.141744,  Lng: -89.271753),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 103 (year 2032),  Design Load: HS 20,  Features Intersected: WHITE WALNUT CREEK,  Facility Carried by Structure: TR 71
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.338,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 733175,  Location: 2 MI E OF US 51 (Lat: 38.097611,  Lng: -89.208781),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 25 (year 2019),  Truck Traffic: 28%,  Average Future Daily Traffic: 26 (year 2032),  Design Load: HS 20,  Features Intersected: REESE CREEK,  Facility Carried by Structure: TR 133 PINTAIL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.148,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 733177,  Location: 0.6 MI N OF FAS 866 (Lat: 38.177756,  Lng: -89.277164),  Route carried "on" structure: County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 1.78m (5.84ft),  Average Daily Traffic: 25 (year 2020),  Average Future Daily Traffic: 26 (year 2032),  Design Load: HS 20,  Features Intersected: BEAUCOUP CREEK,  Facility Carried by Structure: SWAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.120,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 73319,  Location: 2.0 M SW OF TAMAROA (Lat: 38.097767,  Lng: -89.249233),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 125 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 250 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: LITTLE BEAUCOUP CREE,  Facility Carried by Structure: PINTAIL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.639,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 735,  Location: 2.5MI E OF FAS 1821 (Lat: 38.173264,  Lng: -89.282106),  Route carried "on" structure: County highway ,  Year Built: 1953,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 200 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 232 (year 2032),  Features Intersected: LITTLE BEAUCOUP CRK,  Facility Carried by Structure: CO HWY 11
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.879,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 735005,  Location: 1.3 MI N CH 6 (Lat: 38.158733,  Lng: -89.185772),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 50 (year 2019),  Average Future Daily Traffic: 103 (year 2032),  Design Load: HS 20,  Features Intersected: COLLIER CR,  Facility Carried by Structure: TR 298
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.382,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.0m (13.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Fair,  Culverts: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019
Find on map >>   Show street view

Structure Number: 735006,  Location: 1.3 MI N CH 6 (Lat: 38.162250,  Lng: -89.185561),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 50 (year 2019),  Average Future Daily Traffic: 103 (year 2032),  Design Load: HS 20,  Features Intersected: EATON CREEK,  Facility Carried by Structure: TR 298
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.996,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.4m (24.3ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.0m (13.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place
Discuss Tamaroa, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.