Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Tahoka, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 95ft / 28.7mTotal length
  • 36,683Total average daily traffic
  • 5,857Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Tahoka
  • No street view available for this location

Average Bridge Daily Traffic in Tahoka, TX
Average Bridge Truck Traffic in Tahoka, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 20.0%Good
  • 60.0%Satisfactory
  • 20.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 80.0%Satisfactory
  • 20.0%Fair
Find on map >>   Show street view

Structure Number: 5153000680201,  Location: 2.00 MI N OF US 380 (Lat: 33.194983,  Lng: -101.795981),  Route carried "on" structure: State highway 400,  Year Built: 1968,  Status: Open,  Structure Length: 7.62m (25.00ft),  Average Daily Traffic: 1,140 (year 2013),  Truck Traffic: 18%,  Average Future Daily Traffic: 1,600 (year 2033),  Design Load: H 20,  Features Intersected: US 87
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.282,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 51530006802011,  Location: 0.80 MI N OF US 380 (Lat: 33.177864,  Lng: -101.794928),  Route carried "on" structure: US 87,  Year Built: 1968,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 4,622 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 5,300 (year 2033),  Design Load: H 20,  Features Intersected: LOOP 472
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.058,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 51530006802012,  Location: 0.80 MI N OF US 380 (Lat: 33.177794,  Lng: -101.795128),  Route carried "on" structure: US 87,  Year Built: 1968,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 4,181 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 5,300 (year 2033),  Design Load: H 20,  Features Intersected: LOOP 472
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.058,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 51530006802013,  Location: 2.00 MI S OF FM 400 (Lat: 33.166456,  Lng: -101.793839),  Route carried "on" structure: US 380,  Year Built: 1968,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 2,560 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 2,190 (year 2033),  Design Load: H 20,  Features Intersected: US 87
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.330,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 51530006802014,  Location: 1.00 MI S OF US 380 (Lat: 33.152306,  Lng: -101.796631),  Route carried "on" structure: State highway 472,  Year Built: 1968,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 430 (year 2013),  Truck Traffic: 22%,  Average Future Daily Traffic: 610 (year 2033),  Design Load: H 20,  Features Intersected: US 87
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.005,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 5153000680201,  Location: 2.00 MI N OF US 380 (Lat: 33.195000,  Lng: -101.796000),  Route carried "under" structure: US 87,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 8,010 (year 2013),  Truck Traffic: 16%,  Features Intersected: US 87,  Facility Carried by Structure: FM 400
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 22.159,  Lanes on structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 51530006802011,  Location: 0.80 MI N OF US 380 (Lat: 33.177900,  Lng: -101.794900),  Route carried "under" structure: Business State highway 472,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 1,200 (year 2013),  Truck Traffic: 4%,  Features Intersected: LOOP 472,  Facility Carried by Structure: US 87 NB
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 16.140,  Lanes on structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 51530006802012,  Location: 0.80 MI N OF US 380 (Lat: 33.177800,  Lng: -101.795100),  Route carried "under" structure: Business State highway 472,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 1,200 (year 2013),  Truck Traffic: 4%,  Features Intersected: LOOP 472,  Facility Carried by Structure: US 87 SB
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 16.124,  Lanes on structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 51530006802013,  Location: 2.00 MI S OF FM 400 (Lat: 33.166500,  Lng: -101.793800),  Route carried "under" structure: US 87,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 6,550 (year 2013),  Truck Traffic: 16%,  Features Intersected: US 87,  Facility Carried by Structure: US 380
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 25.362,  Lanes on structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 51530006802014,  Location: 1.00 MI S OF US 380 (Lat: 33.152300,  Lng: -101.796600),  Route carried "under" structure: US 87,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 6,790 (year 2013),  Truck Traffic: 16%,  Features Intersected: US 87,  Facility Carried by Structure: LOOP 472
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 26.981,  Lanes on structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Discuss Tahoka, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.