Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Stockton, Wisconsin (WI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 144ft / 43.5mTotal length
  • 42,687Total average daily traffic
  • 248Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Stockton
  • No street view available for this location

New bridges in Stockton, WI - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 11940-1949
  • 11950-1959
  • 11990-1999
  • 52000-2009
Average Bridge Daily Traffic in Stockton, WI
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Very good
  • 50.0%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 75.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: B49009,  Location: 1.0M E JCT CTH P (Lat: 44.500669,  Lng: -89.596167),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 23.72m (77.82ft),  Average Daily Traffic: 4,180 (year 2019),  Average Future Daily Traffic: 4,598 (year 2039),  Design Load: HS 20,  Features Intersected: WISCONSIN RIVER,  Facility Carried by Structure: CTH HH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 34.0m (111.5ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 0.0m,  Curb-To-Curb Width: 17.6m (57.7ft),  Out-to-Out Width: 23.7m (77.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B490095,  Location: TOWN OF STOCKTON (Lat: 44.520800,  Lng: -89.446344),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 7.00m (22.97ft),  Average Daily Traffic: 2,700 (year 2019),  Average Future Daily Traffic: 5,100 (year 2039),  Design Load: HS 20,  Features Intersected: USH 10,  Facility Carried by Structure: CTH J NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 73.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B490096,  Location: TOWN OF STOCKTON (Lat: 44.521439,  Lng: -89.446647),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 7.00m (22.97ft),  Average Daily Traffic: 3,100 (year 2019),  Average Future Daily Traffic: 5,100 (year 2039),  Design Load: HS 20,  Features Intersected: USH 10,  Facility Carried by Structure: CTH J SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 73.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B490164,  Location: 0.35 M S JCT USH 10 (Lat: 44.513028,  Lng: -89.446083),  Route carried "on" structure: County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 4,140 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,554 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: CANADIAN NATIONAL RR,  Facility Carried by Structure: CTH J
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.7m (64.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: P490901,  Location: 0.8M E JCT STH 161 (Lat: 44.475564,  Lng: -89.295236),  Route carried "on" structure: City street ,  Year Built: 1950,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 47 (year 2019),  Average Future Daily Traffic: 51 (year 2039),  Design Load: H 15,  Features Intersected: TOMORROW RIVER,  Facility Carried by Structure: LRD LAKE MEYERS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.5m (4.9ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B490095,  Location: 6.9M E JCT USH 51 (Lat: 44.520800,  Lng: -89.446344),  Route carried "under" structure: US 10,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 14,200 (year 2019),  Features Intersected: USH 10,  Facility Carried by Structure: CTH J NB
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: B490096,  Location: 6.8M E JCT USH 51 (Lat: 44.521439,  Lng: -89.446647),  Route carried "under" structure: US 10,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 14,200 (year 2019),  Features Intersected: USH 10,  Facility Carried by Structure: CTH J SB
Minimum Vertical Clearance: 5.68m (18.64ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: P490044,  Location: 0.2M S JCT USH 10 (Lat: 44.510433,  Lng: -89.426247),  Route carried "under" structure: City street ,  Year Built: 1940,  Structure Length: 0. m,  Average Daily Traffic: 40 (year 2019),  Features Intersected: LRD CUSTER RD,  Facility Carried by Structure: SOO LINE
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 0.000,  Lanes under structure: 1,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: P490045,  Location: 0.6M S JCT USH 10 (Lat: 44.511719,  Lng: -89.467258),  Route carried "under" structure: City street ,  Year Built: 1920,  Structure Length: 0. m,  Average Daily Traffic: 40 (year 2019),  Features Intersected: LRD STOCKTON RD,  Facility Carried by Structure: SOO LINE
Minimum Vertical Clearance: 3.47m (11.38ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 10.2m (33.5ft)

Find on map >>   Show street view

Structure Number: P490908,  Location: 0.1M S JCT USH 10 (Lat: 44.500978,  Lng: -89.387436),  Route carried "under" structure: City street ,  Year Built: 1920,  Structure Length: 0. m,  Average Daily Traffic: 40 (year 2019),  Features Intersected: LRD SMOKEY RD,  Facility Carried by Structure: SOO LINE
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 11.6m (38.1ft)

Discuss Stockton, Wisconsin (WI) on our hugely popular Wisconsin forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.