Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Staunton, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 236ft / 71.6mTotal length
  • $765,000Total costs
  • 96,250Total average daily traffic
  • 27,709Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Staunton
  • No street view available for this location

New bridges in Staunton, IL - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 11920-1929
  • 11930-1939
  • 21950-1959
  • 11960-1969
  • 51970-1979
  • 11980-1989
  • 21990-1999
  • 22000-2009
  • 12010-2019
Reconstructed bridges in Staunton, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 31990-1999
Average Bridge Daily Traffic in Staunton, IL
Average Bridge Truck Traffic in Staunton, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 66.7%Good
  • 25.0%Satisfactory
  • 8.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Very good
  • 8.3%Good
  • 25.0%Satisfactory
  • 16.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Very good
  • 11.1%Good
  • 11.1%Satisfactory
  • 11.1%Fair
Find on map >>   Show street view

Structure Number: 590009,  Location: 2.0 M N STAUNTON (Lat: 39.046292,  Lng: -89.806461),  Route carried "on" structure: State highway 4,  Year Built: 1959,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 6.93m (22.74ft),  Average Daily Traffic: 2,800 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,323 (year 2032),  Design Load: HS 20,  Features Intersected: NSRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 170.312,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.3m (86.3ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.95m (22.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $510,000,  Roadway Improvement Cost: $51,000,  Total Project Cost: $765,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 59001,  Location: 1.0 M N STAUNTON (Lat: 39.036614,  Lng: -89.801961),  Route carried "on" structure: State highway 4,  Year Built: 1921,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 9.42m (30.91ft),  Average Daily Traffic: 2,800 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,323 (year 2032),  Design Load: HS 20,  Features Intersected: CAHOKIA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 169.137,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.0m (85.3ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 590044,  Location: .8M N STAUNTON INTCH (Lat: 39.031761,  Lng: -89.753711),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 7.74m (25.39ft),  Average Daily Traffic: 2,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,366 (year 2032),  Design Load: HS 20,  Features Intersected: I-55,  Facility Carried by Structure: WILLIAMSON RD/SBI
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.515,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 92.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 590045,  Location: I-55 INT @ STAUNTON (Lat: 39.020881,  Lng: -89.750058),  Route carried "on" structure: Other road ,  Year Built: 1975,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 4,050 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 3,424 (year 2032),  Design Load: HS 20,  Features Intersected: FAI 55,  Facility Carried by Structure: STAUNTON CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.846,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 33.2m (108.9ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 593011,  Location: 3 M S WILSONVILLE (Lat: 39.020325,  Lng: -89.861511),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 5.99m (19.65ft),  Average Daily Traffic: 125 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 76 (year 2032),  Design Load: HS 20,  Features Intersected: W FRK CAHOKIA CR,  Facility Carried by Structure: TR 477
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.255,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 593014,  Location: 1.0 MI W STAUNTON (Lat: 39.030644,  Lng: -89.817422),  Route carried "on" structure: County highway ,  Year Built: 1961,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 900 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,108 (year 2032),  Design Load: HS 20,  Features Intersected: CAHOKIA CREEK,  Facility Carried by Structure: FAS 736
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.418,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 593513,  Location: 3 MI W STAUTON (Lat: 39.005883,  Lng: -89.864178),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 75 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 76 (year 2032),  Design Load: HS 20,  Features Intersected: CAHOKIA CREEK,  Facility Carried by Structure: TR 473
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.566,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 593518,  Location: 1 MI W STAUTON (Lat: 39.016969,  Lng: -89.823750),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 7.20m (23.62ft),  Average Daily Traffic: 250 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 151 (year 2032),  Design Load: HS 20,  Features Intersected: CAHOKIA CRK.,  Facility Carried by Structure: TR 477C
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.667,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 59601,  Location: STAUNTON RESERVOIR (Lat: 39.042542,  Lng: -89.781111),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 200 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 604 (year 2032),  Design Load: HS 20,  Features Intersected: STAUNTON RESERVOIR,  Facility Carried by Structure: TR 457
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.740,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.1m (72.5ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 603008,  Location: 4MI E PRRTWN (Lat: 38.983683,  Lng: -89.851153),  Route carried "on" structure: County highway ,  Year Built: 1953,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 1,650 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,643 (year 2032),  Design Load: HS 20,  Features Intersected: CAHOKIA CK,  Facility Carried by Structure: FAS 2735
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.911,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Fair,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 603251,  Location: 1.9 M W OFSTAUNTON (Lat: 38.998453,  Lng: -89.837225),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 8.78m (28.81ft),  Average Daily Traffic: 150 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 133 (year 2032),  Design Load: HS 20,  Features Intersected: CAHOKIA CREEK,  Facility Carried by Structure: VFW RD/ TR 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.235,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 603357,  Location: 0.5MI SW STAUNTON (Lat: 38.991611,  Lng: -89.810792),  Route carried "on" structure: County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 53 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: TRIB TO CAHOKIA CK,  Facility Carried by Structure: TR 244
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.837,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.0m (42.7ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 590043,  Location: 1.1MI N STAUNTON INT (Lat: 39.036181,  Lng: -89.754997),  Route carried "under" structure: Interstate 55,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 26,000 (year 2021),  Truck Traffic: 34%,  Features Intersected: FAI 55,  Facility Carried by Structure: Norfolk Southern R
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 66.834,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 590044,  Location: .8M N STAUNTON INTCH (Lat: 39.032006,  Lng: -89.753211),  Route carried "under" structure: Interstate 55,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 26,000 (year 2021),  Truck Traffic: 34%,  Features Intersected: I-55,  Facility Carried by Structure: WILLIAMSON RD/SBI
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 66.351,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.8m (101.0ft)

Find on map >>   Show street view

Structure Number: 590045,  Location: I-55 INT @ STAUNTON (Lat: 39.020886,  Lng: -89.749472),  Route carried "under" structure: Interstate 55,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 26,000 (year 2021),  Truck Traffic: 34%,  Features Intersected: FAI 55,  Facility Carried by Structure: STAUNTON CONNECTOR
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 65.080,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 5999,  Location: 2 M ENE STAUNTON (Lat: 39.040431,  Lng: -89.750581),  Route carried "under" structure: County highway ,  Year Built: 1938,  Structure Length: 0. m,  Average Daily Traffic: 2,900 (year 2021),  Truck Traffic: 3%,  Features Intersected: FAS 1766,  Facility Carried by Structure: N&W RR
Minimum Vertical Clearance: 4.22m (13.85ft),  Kilometerpoint: 1.368,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 29.3m (96.1ft)

Find on map >>   Show street view

Structure Number: 599911,  Location: WEST EDGE STAUNTON (Lat: 39.012986,  Lng: -89.803450),  Route carried "under" structure: County highway ,  Year Built: 1891,  Structure Length: 0. m,  Average Daily Traffic: 250 (year 2021),  Truck Traffic: 2%,  Features Intersected: TR 0477,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 8.69m (28.51ft),  Kilometerpoint: 6.598,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 21.9m (71.9ft)

Discuss Staunton, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.