Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Spring Hope, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 253ft / 77.2mTotal length
  • 121,410Total average daily traffic
  • 15,859Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Spring Hope
  • No street view available for this location

New bridges in Spring Hope, NC - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 31950-1959
  • 131970-1979
  • 11980-1989
  • 11990-1999
  • 12010-2019
Average Bridge Daily Traffic in Spring Hope, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Excellent
  • 9.1%Very good
  • 27.3%Good
  • 45.5%Satisfactory
  • 9.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 9.1%Excellent
  • 9.1%Very good
  • 9.1%Good
  • 54.5%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 9.1%Excellent
  • 27.3%Good
  • 45.5%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 62.5%Good
  • 12.5%Satisfactory
  • 25.0%Fair
Find on map >>   Show street view

Structure Number: 1270019,  Location: 1.2 MI. E. JCT. NC231 (Lat: 35.925986,  Lng: -78.145694),  Route carried "on" structure: US 64,  Year Built: 1977,  Status: Open,  Structure Length: 9.93m (32.58ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2020,  Underwater Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270027,  Location: 2.6 MI N. OF JCT SR1137 (Lat: 35.905214,  Lng: -78.112875),  Route carried "on" structure: State highway 1145,  Year Built: 1980,  Status: Open,  Structure Length: 9.29m (30.48ft),  Average Daily Traffic: 370 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 740 (year 2040),  Design Load: HS 15,  Features Intersected: TAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 85.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2020,  Underwater Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270029,  Location: 0.4MI.E. OF JCT.SR1331 (Lat: 35.928131,  Lng: -78.148094),  Route carried "on" structure: Alternate US 64,  Year Built: 1952,  Status: Open,  Structure Length: 9.60m (31.50ft),  Average Daily Traffic: 2,700 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,400 (year 2040),  Design Load: HS 15,  Features Intersected: TAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 47.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2020,  Underwater Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1270045,  Location: .1 MI SOUTH JCT. US64 ALT (Lat: 35.930056,  Lng: -78.135947),  Route carried "on" structure: State highway 1148,  Year Built: 1977,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 900 (year 2011),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,800 (year 2040),  Design Load: HS 20,  Features Intersected: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.6m (116.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1270046,  Location: 1.0 MI.NORTH OF NC581 (Lat: 35.931731,  Lng: -78.118394),  Route carried "on" structure: State highway 1148,  Year Built: 1977,  Status: Open,  Structure Length: 7.95m (26.08ft),  Average Daily Traffic: 800 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HS 15,  Features Intersected: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 41.1m (134.8ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270047,  Location: 0.2 MI. N. JCT. SR1145 (Lat: 35.932322,  Lng: -78.108561),  Route carried "on" structure: State highway 1144,  Year Built: 1978,  Status: Open,  Structure Length: 7.10m (23.29ft),  Average Daily Traffic: 890 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,780 (year 2040),  Design Load: HS 15,  Features Intersected: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 70.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1270081,  Location: 0.1 MI.W.OF SR1331 (Lat: 35.940247,  Lng: -78.148972),  Route carried "on" structure: State highway 1315,  Year Built: 1993,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 450 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 900 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TURKEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1270086,  Location: 0.4MI. N. JCT. SR1319 (Lat: 35.955253,  Lng: -78.143378),  Route carried "on" structure: State highway 1002,  Year Built: 2018,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 750 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,500 (year 2040),  Design Load: HL 93,  Features Intersected: TURKEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1270091,  Location: 1.4 MI.N.JCT.NC97 (Lat: 35.882097,  Lng: -78.089428),  Route carried "on" structure: State highway 581,  Year Built: 1949,  Status: Posted for load,  Structure Length: 9.47m (31.07ft),  Average Daily Traffic: 2,200 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,400 (year 2040),  Design Load: H 15,  Features Intersected: TAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 6,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 29.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2020,  Underwater Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1270145,  Location: 0.3MI.N. OF SR1145 (Lat: 35.931483,  Lng: -78.097428),  Route carried "on" structure: State highway 581,  Year Built: 1977,  Status: Open,  Structure Length: 8.35m (27.40ft),  Average Daily Traffic: 4,600 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 41.4m (135.8ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 18.8m (61.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270267,  Location: 1.8 MI.W. OF JCT.SR1306 (Lat: 35.938553,  Lng: -78.081003),  Route carried "on" structure: State highway 1915,  Year Built: 1959,  Status: Posted for load,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 850 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,700 (year 2040),  Features Intersected: SAPONY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 26.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1270288,  Location: 0.1 MI.S.SR1310 (Lat: 36.001797,  Lng: -78.121322),  Route carried "on" structure: State highway 1321,  Year Built: 1953,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 900 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,800 (year 2040),  Design Load: HS 20,  Features Intersected: LITTLE PEACHTREE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1270045,  Location: .1 MI SOUTH JCT. US64 ALT (Lat: 35.930056,  Lng: -78.135947),  Route carried "under" structure: US 64,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1148
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 136.552,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.6m (116.8ft)

Find on map >>   Show street view

Structure Number: 1270045,  Location: .1 MI SOUTH JCT. US64 ALT (Lat: 35.930056,  Lng: -78.135947),  Route carried "under" structure: US 64,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1148
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 136.552,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.6m (116.8ft)

Find on map >>   Show street view

Structure Number: 1270046,  Location: 1.0 MI.NORTH OF NC581 (Lat: 35.931731,  Lng: -78.118394),  Route carried "under" structure: US 64,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1148
Minimum Vertical Clearance: 4.84m (15.88ft),  Kilometerpoint: 137.161,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 1270046,  Location: 1.0 MI.NORTH OF NC581 (Lat: 35.931731,  Lng: -78.118394),  Route carried "under" structure: US 64,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1148
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 136.856,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 1270047,  Location: 0.2 MI. N. JCT. SR1145 (Lat: 35.932322,  Lng: -78.108561),  Route carried "under" structure: US 64,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1144
Minimum Vertical Clearance: 4.84m (15.88ft),  Kilometerpoint: 137.161,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 1270047,  Location: 0.2 MI. N. JCT. SR1145 (Lat: 35.932322,  Lng: -78.108561),  Route carried "under" structure: US 64,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1144
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 136.856,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 1270145,  Location: 0.3MI.N. OF SR1145 (Lat: 35.931483,  Lng: -78.097428),  Route carried "under" structure: US 64,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 11,500 (year 2017),  Truck Traffic: 14%,  Features Intersected: NC581
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.4m (135.8ft)

Find on map >>   Show street view

Structure Number: 1270145,  Location: 0.3MI.N. OF SR1145 (Lat: 35.931483,  Lng: -78.097428),  Route carried "under" structure: US 64,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 11,500 (year 2017),  Truck Traffic: 14%,  Features Intersected: NC581
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.4m (135.8ft)

Discuss Spring Hope, North Carolina (NC) on our hugely popular North Carolina forum.