Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for South Weber, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 207ft / 62.6mTotal length
  • 286,213Total average daily traffic
  • 76,593Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for South Weber
  • No street view available for this location

New bridges in South Weber, UT - historical statistics
  • New bridges - historical statistics
  • 61960-1969
  • 21970-1979
  • 21980-1989
  • 11990-1999
  • 32000-2009
Average Bridge Daily Traffic in South Weber, UT
Average Bridge Truck Traffic in South Weber, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Good
  • 72.7%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 45.5%Good
  • 36.4%Satisfactory
  • 18.2%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.2%Good
  • 36.4%Satisfactory
  • 45.5%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 44.4%Very good
  • 22.2%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 11015F,  Location: SE AREA OF SO.WEBER CITY (Lat: 41.121253,  Lng: -111.915314),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 1,260 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,531 (year 2040),  Design Load: HL 93,  Features Intersected: WEBER-DAVIS CANAL,  Facility Carried by Structure: PEACHWOOD DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.118,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.5m (47.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 11022D,  Location: 7920 S.1900 E., SO.WEBER (Lat: 41.123006,  Lng: -111.929894),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 630 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 765 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER-DAVIS CANAL,  Facility Carried by Structure: 1900 EAST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.122,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 23 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 57022C,  Location: ON THE SO WEBER-UINTAH RD (Lat: 41.146994,  Lng: -111.960017),  Route carried "on" structure: City street 3342,  Year Built: 1986,  Status: Open,  Structure Length: 4.07m (13.35ft),  Average Daily Traffic: 96 (year 2020),  Average Future Daily Traffic: 120 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER RIVER,  Facility Carried by Structure: UINTAH TOWN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.922,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.9m (130.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: C 644,  Location: SOUTH WEBER INTERCHANGE (Lat: 41.149386,  Lng: -111.968914),  Route carried "on" structure: City street 1508,  Year Built: 1974,  Status: Open,  Structure Length: 14.70m (48.23ft),  Average Daily Traffic: 3,715 (year 2020),  Average Future Daily Traffic: 4,644 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-84 (SR-84) EBL & W,  Facility Carried by Structure: 500 E.ST.-SO.WEBER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.077,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 17.2m (56.4ft),  Skew: 23 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 55.3m (181.4ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: D 763,  Location: POWER PLANT WEBER CANYON (Lat: 41.137711,  Lng: -111.881544),  Route carried "on" structure: Interstate 84,  Year Built: 1964,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 20,010 (year 2020),  Truck Traffic: 37%,  Average Future Daily Traffic: 25,013 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: U.P.and L.CO.PENSTOCK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 144.122,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: E2462,  Location: 1.1 MILE SO. UINTAH JCT. (Lat: 41.124669,  Lng: -111.907947),  Route carried "on" structure: US ,  Year Built: 2001,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 45,615 (year 2020),  Truck Traffic: 33%,  Average Future Daily Traffic: 57,019 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER-DAVIS CANAL,  Facility Carried by Structure: US-89 (SR-89)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.033,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 71.7m (235.2ft),  Skew: 31 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: F 671,  Location: 1 Mi.So.I-80,US-89 Intchg (Lat: 41.128064,  Lng: -111.908572),  Route carried "on" structure: State highway 60,  Year Built: 2001,  Status: Open,  Structure Length: 6.19m (20.31ft),  Average Daily Traffic: 3,381 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,226 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US-89, (SR-89)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.677,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.2m (108.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 24.0m (78.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1F 175,  Location: 0.3 MI.SO.UINTAH JCT. (Lat: 41.134367,  Lng: -111.911864),  Route carried "on" structure: US ,  Year Built: 1967,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 49,785 (year 2020),  Truck Traffic: 31%,  Average Future Daily Traffic: 62,232 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER RIVER,  Facility Carried by Structure: US-89 (SR-89) NBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.225,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.5m (34.4ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2C 477,  Location: BY POWER PLANT WEBER CYN. (Lat: 41.137883,  Lng: -111.886842),  Route carried "on" structure: Interstate 84,  Year Built: 1967,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 13.16m (43.18ft),  Average Daily Traffic: 20,010 (year 2020),  Truck Traffic: 37%,  Average Future Daily Traffic: 25,013 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 143.818,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 7 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 95,  Location: .3 MI.WEST OF UINTAH JCT. (Lat: 41.136825,  Lng: -111.919411),  Route carried "on" structure: Interstate 84,  Year Built: 1964,  Status: Open,  Structure Length: 3.61m (11.84ft),  Average Daily Traffic: 19,408 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 24,260 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 141.032,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Very good,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3F 175,  Location: 0.3 MI.SO.UINTAH JCT. (Lat: 41.134908,  Lng: -111.912433),  Route carried "on" structure: US ,  Year Built: 1967,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 29,870 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 37,338 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER RIVER,  Facility Carried by Structure: US-89 (SR-89) SBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.025,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.5m (34.4ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4F 95,  Location: .3 MI.WEST OF UINTAH JCT. (Lat: 41.137033,  Lng: -111.919000),  Route carried "on" structure: Interstate 84,  Year Built: 1964,  Status: Open,  Structure Length: 3.61m (11.84ft),  Average Daily Traffic: 19,408 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 24,260 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 140.927,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: C 644,  Location: SOUTH WEBER INTERCHANGE (Lat: 41.149386,  Lng: -111.968914),  Route carried "under" structure: Interstate 84,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 20,299 (year 2020),  Truck Traffic: 27%,  Features Intersected: I-84 (SR-84) EBL & W,  Facility Carried by Structure: 500 E.ST.-SO.WEBER
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 136.141,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 55.3m (181.4ft)

Find on map >>   Show street view

Structure Number: F 671,  Location: 1 Mi.So.I-80,US-89 Intchg (Lat: 41.128064,  Lng: -111.908572),  Route carried "under" structure: US 89,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 52,726 (year 2020),  Truck Traffic: 16%,  Features Intersected: US-89, (SR-89),  Facility Carried by Structure: SR-60,SO.WEBER DR.
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 652.958,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Discuss South Weber, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.