Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Sophia, West Virginia (WV)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 89ft / 27.3mTotal length
  • $2,150,000Total costs
  • 31,870Total average daily traffic
  • 1,754Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Sophia
  • No street view available for this location

New bridges in Sophia, WV - historical statistics
  • New bridges - historical statistics
  • 21960-1969
  • 11980-1989
  • 82000-2009
Average Bridge Daily Traffic in Sophia, WV
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Good
  • 14.3%Satisfactory
  • 42.9%Fair
  • 28.6%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Good
  • 57.1%Fair
  • 28.6%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 28.6%Satisfactory
  • 42.9%Fair
  • 28.6%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Good
  • 66.7%Satisfactory
Find on map >>   Show street view

Structure Number: 41A112,  Location: 1.21 MI E OF WV 16 (Lat: 37.680889,  Lng: -81.289500),  Route carried "on" structure: County highway 3000,  Year Built: 1985,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 40 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 74 (year 2039),  Design Load: HS 20,  Features Intersected: WINDING GULF,  Facility Carried by Structure: CR 30
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.947,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.15m (3.77ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $350,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $450,000 ( Estimate for 2021),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41A113,  Location: 0.64 MI. WEST OF CR. 32 (Lat: 37.688339,  Lng: -81.282750),  Route carried "on" structure: County highway 3000,  Year Built: 1968,  Status: Open,  Structure Length: 1.56m (5.12ft),  Average Daily Traffic: 200 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 252 (year 2038),  Features Intersected: WINDING GULF,  Facility Carried by Structure: COUNTY ROUTE 30
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.913,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.1m (23.3ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 88.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 1.56m (5.12ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2020,  Other Special Inspection Date: Febuary 2021,  Bridge Improvement Cost: $1,200,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $1,300,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 41A294,  Location: 0.58 MILE S OF WV 16 (Lat: 37.718819,  Lng: -81.254061),  Route carried "on" structure: State highway 12100,  Year Built: 2004,  Status: Open,  Structure Length: 7.26m (23.82ft),  Average Daily Traffic: 3,900 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,914 (year 2038),  Design Load: HL 93,  Features Intersected: WV 54,  Facility Carried by Structure: WV ROUTE 121
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.196,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 41.1m (134.8ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41A295,  Location: 0.58 MILE S OF WV 16 (Lat: 37.718839,  Lng: -81.254561),  Route carried "on" structure: State highway 12100,  Year Built: 2004,  Status: Open,  Structure Length: 7.26m (23.82ft),  Average Daily Traffic: 3,900 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,914 (year 2038),  Design Load: HL 93,  Features Intersected: WV 54,  Facility Carried by Structure: WV ROUTE 121
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.196,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 41.1m (134.8ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41A296,  Location: 0.33 MILE S OF WV 16 (Lat: 37.721939,  Lng: -81.251939),  Route carried "on" structure: State highway 12100,  Year Built: 2004,  Status: Open,  Structure Length: 4.13m (13.55ft),  Average Daily Traffic: 3,900 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,914 (year 2038),  Design Load: HL 93,  Features Intersected: WV 121,  Facility Carried by Structure: WV 121
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.598,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.7m (130.2ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41A297,  Location: 0.33 MILE S OF WV 16 (Lat: 37.722461,  Lng: -81.251981),  Route carried "on" structure: State highway 12100,  Year Built: 2004,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 3,900 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,914 (year 2038),  Design Load: HL 93,  Features Intersected: WV16 Ramp,  Facility Carried by Structure: WV 121
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.598,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.7m (146.7ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41A324,  Location: 0.08 Mi. South of Co. 30 (Lat: 37.679961,  Lng: -81.289831),  Route carried "on" structure: Other road 90265,  Year Built: 1965,  Status: Posted for load,  Structure Length: 1.30m (4.27ft),  Average Daily Traffic: 30 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 38 (year 2039),  Features Intersected: Winding Gulf,  Facility Carried by Structure: Harp Route 902/65
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 6.8m (22.3ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Channel: Good,  Operating Rating: 10.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 6.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $350,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $400,000 ( Estimate for 2020),  Deck Structure Type: Wood or Timber
Find on map >>   Show street view

Structure Number: 41A294,  Location: 0.58 MILE S OF WV 16 (Lat: 37.718839,  Lng: -81.254069),  Route carried "under" structure: State highway 5400,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 7,000 (year 0009),  Truck Traffic: 6%,  Features Intersected: WV 54,  Facility Carried by Structure: WV ROUTE 121
Minimum Vertical Clearance: 6.99m (22.93ft),  Kilometerpoint: 16.496,  Lanes on structure: 2,  Lanes under structure: 5,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 41A295,  Location: 0.58 MILE S OF WV 16 (Lat: 37.718800,  Lng: -81.254339),  Route carried "under" structure: State highway 5400,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 7,000 (year 0009),  Truck Traffic: 6%,  Features Intersected: WV 54,  Facility Carried by Structure: WV ROUTE 121
Minimum Vertical Clearance: 8.33m (27.33ft),  Kilometerpoint: 16.560,  Lanes on structure: 2,  Lanes under structure: 5,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 41A296,  Location: 0.33 MILE S OF WV 16 (Lat: 37.721950,  Lng: -81.251961),  Route carried "under" structure: Ramp State highway 1600,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 0009),  Truck Traffic: 6%,  Features Intersected: WV 121,  Facility Carried by Structure: WV 121
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.322,  Lanes on structure: 3,  Lanes under structure: 1,  Length of Maximum Span: 39.7m (130.2ft)

Find on map >>   Show street view

Structure Number: 41A297,  Location: 0.33 MILE S OF WV 16 (Lat: 37.722261,  Lng: -81.251981),  Route carried "under" structure: Ramp State highway 1600,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 0009),  Truck Traffic: 6%,  Features Intersected: WV16 Ramp,  Facility Carried by Structure: WV 121
Minimum Vertical Clearance: 6.30m (20.67ft),  Kilometerpoint: 0.322,  Lanes on structure: 2,  Lanes under structure: 1,  Length of Maximum Span: 44.7m (146.7ft)

Discuss Sophia, West Virginia (WV) on our hugely popular West Virginia forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.