Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for San Martin, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 200ft / 61.3mTotal length
  • $925,000Total costs
  • 713,310Total average daily traffic
  • 89,021Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for San Martin
  • No street view available for this location

New bridges in San Martin, CA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 11920-1929
  • 11930-1939
  • 11940-1949
  • 121970-1979
  • 31980-1989
  • 12000-2009
Average Bridge Daily Traffic in San Martin, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 66.7%Good
  • 16.7%Fair
  • 16.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 58.3%Good
  • 33.3%Fair
  • 8.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 83.3%Good
  • 8.3%Satisfactory
  • 8.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.7%Excellent
  • 23.1%Very good
  • 46.2%Good
  • 23.1%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Good
  • 75.0%Satisfactory
Find on map >>   Show street view

Structure Number: 37 0272,  Location: 04-SCL-101-R13.74 (Lat: 37.104242,  Lng: -121.611642),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 7.56m (24.80ft),  Average Daily Traffic: 3,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,922 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: MIDDLE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.5m (123.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0324,  Location: 04-SCL-101-R11.15 (Lat: 37.071214,  Lng: -121.590200),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 1,400 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,735 (year 2040),  Design Load: HS 20,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: CHURCH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.4m (116.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0331L,  Location: 04-SCL-101-R10.63 (Lat: 37.064347,  Lng: -121.586831),  Route carried "on" structure: US 101,  Year Built: 1973,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 55,000 (year 2009),  Truck Traffic: 13%,  Average Future Daily Traffic: 78,733 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LLAGAS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.630,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0331R,  Location: 04-SCL-101-R10.63 (Lat: 37.064444,  Lng: -121.586467),  Route carried "on" structure: US 101,  Year Built: 1972,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 55,000 (year 2009),  Truck Traffic: 13%,  Average Future Daily Traffic: 78,733 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LLAGAS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.630,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.41m (11.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $551,000,  Roadway Improvement Cost: $110,000,  Total Project Cost: $925,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0332,  Location: 04-SCL-101-R12.46 (Lat: 37.088675,  Lng: -121.599742),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 7.10m (23.29ft),  Average Daily Traffic: 6,000 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,206 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: SAN MARTIN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0392,  Location: 04-SCL-101-R13.87 (Lat: 37.105739,  Lng: -121.612583),  Route carried "on" structure: US 101,  Year Built: 1972,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 112,000 (year 2009),  Truck Traffic: 13%,  Average Future Daily Traffic: 170,728 (year 2040),  Features Intersected: LITTLE LLAGAS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.870,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 28.4m (93.2ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 37C0169,  Location: 0.3 MI E/O MONTEREY HWY (Lat: 37.086636,  Lng: -121.605436),  Route carried "on" structure: County highway ,  Year Built: 1948,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 7,230 (year 2014),  Truck Traffic: 8%,  Average Future Daily Traffic: 9,965 (year 2042),  Design Load: H 15,  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: SAN MARTIN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.2m (33.5ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0178,  Location: 0.2 MI E/O SH 101 (Lat: 37.089933,  Lng: -121.596072),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 6,080 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,765 (year 2042),  Design Load: HS 20,  Features Intersected: E LITTLE LLAGAS CREEK,  Facility Carried by Structure: SAN MARTIN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0215,  Location: 0.25 MI N CALIF AVE (Lat: 37.095456,  Lng: -121.616411),  Route carried "on" structure: County highway ,  Year Built: 1938,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 11,440 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,367 (year 2042),  Design Load: H 15,  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: MONTEREY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 19.3m (63.3ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 38.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0519,  Location: 0.5 MI W NEW AVE (Lat: 37.048672,  Lng: -121.559150),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 3.92m (12.86ft),  Average Daily Traffic: 2,540 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,941 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: BUENA VISTA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0523,  Location: 0.3 MI S/ O CHURCH AVE (Lat: 37.072267,  Lng: -121.575250),  Route carried "on" structure: County highway ,  Year Built: 1915,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 1,070 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,285 (year 2042),  Features Intersected: CHURCH CREEK,  Facility Carried by Structure: CENTER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.70m (2.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0525,  Location: 0.3 MI W SH 101 (Lat: 37.069175,  Lng: -121.595983),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 1,290 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,054 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: CHURCH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0526,  Location: 0.3 MI E OF SH 101 (Lat: 37.073039,  Lng: -121.585047),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 1,290 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,665 (year 2042),  Features Intersected: LITTLE LLAGAS CREEK,  Facility Carried by Structure: CHURCH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 4.0m (13.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0549,  Location: 0.8 MI N SAN MARTIN AVE (Lat: 37.096069,  Lng: -121.612481),  Route carried "on" structure: County highway ,  Year Built: 1925,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 1,780 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,000 (year 2037),  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: LLAGAS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 24.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 14.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.65m (5.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $276,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0566,  Location: BTWN SH 101/NEW AVE (Lat: 37.057500,  Lng: -121.570186),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 2,090 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,200 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: RUCKER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0824,  Location: .1 MI SW/O WATSONVILLE RD (Lat: 37.053706,  Lng: -121.662053),  Route carried "on" structure: County highway ,  Year Built: 2007,  Status: Open,  Structure Length: 2.28m (7.48ft),  Average Daily Traffic: 100 (year 2008),  Truck Traffic: 2%,  Average Future Daily Traffic: 306 (year 2037),  Features Intersected: UVAS CREEK,  Facility Carried by Structure: HERITAGE WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.9m (29.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0272,  Location: 04-SCL-101-R13.74 (Lat: 37.104242,  Lng: -121.611642),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 112,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: MIDDLE AVENUE
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 13.740,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 37.5m (123.0ft)

Find on map >>   Show street view

Structure Number: 37 0324,  Location: 04-SCL-101-R11.15 (Lat: 37.071214,  Lng: -121.590200),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 112,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: CHURCH AVENUE
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 11.150,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 37 033,  Location: 04-SCL-101-R10.27 (Lat: 37.059186,  Lng: -121.584906),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 110,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: MASTEN AVENUE
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 10.270,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 37 0332,  Location: 04-SCL-101-R12.46 (Lat: 37.088675,  Lng: -121.599742),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 112,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: SAN MARTIN AVENUE
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 12.460,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 36.0m (118.1ft)

Discuss San Martin, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.