Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Rutland, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 92ft / 28.1mTotal length
  • 54,845Total average daily traffic
  • 18,986Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rutland
  • No street view available for this location

New bridges in Rutland, IL - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 21960-1969
  • 51980-1989
  • 41990-1999
Average Bridge Daily Traffic in Rutland, IL
Average Bridge Truck Traffic in Rutland, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 37.5%Very good
  • 37.5%Good
  • 25.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 25.0%Good
  • 50.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 37.5%Very good
  • 25.0%Satisfactory
  • 25.0%Fair
  • 12.5%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Very good
  • 33.3%Good
  • 16.7%Satisfactory
Find on map >>   Show street view

Structure Number: 503112,  Location: E 8TH N 250 (Lat: 40.963003,  Lng: -89.008203),  Route carried "on" structure: County highway ,  Year Built: 1932,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 25 (year 2016),  Truck Traffic: 40%,  Average Future Daily Traffic: 29 (year 2032),  Design Load: HS 20,  Features Intersected: LONG POINT CR,  Facility Carried by Structure: TR 142B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.099,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.9m (29.2ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 503241,  Location: N 6TH E 750 (Lat: 41.013847,  Lng: -89.018367),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 10 (year 2016),  Average Future Daily Traffic: 11 (year 2032),  Design Load: HS 15,  Features Intersected: CREEK,  Facility Carried by Structure: TR 561
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.446,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 3.4m (11.2ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.8m (35.4ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 503407,  Location: E 7TH N 580 (Lat: 41.010458,  Lng: -89.027183),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 25 (year 2016),  Truck Traffic: 40%,  Average Future Daily Traffic: 28 (year 2032),  Design Load: HS 15,  Features Intersected: PRAIRIE CR,  Facility Carried by Structure: TR 122
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.354,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Good,  Operating Rating: 32.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 503524,  Location: N6TH RD, E 815 (Lat: 41.014133,  Lng: -89.004458),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 1.56m (5.12ft),  Average Daily Traffic: 10 (year 2016),  Average Future Daily Traffic: 11 (year 2032),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: TR 561
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.621,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 50353,  Location: N5TH, E670TH (Lat: 40.999028,  Lng: -89.034744),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 100 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 168 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: TR 563
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.062,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 50502,  Location: E 9TH,N 6TH (Lat: 41.013997,  Lng: -88.988397),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 50 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 140 (year 2032),  Design Load: HS 20,  Features Intersected: CREEK,  Facility Carried by Structure: TR 152A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.764,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018
Find on map >>   Show street view

Structure Number: 620053,  Location: 2.02 MI S 0F ILL 17 (Lat: 40.998803,  Lng: -89.054547),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 725 (year 2019),  Truck Traffic: 15%,  Average Future Daily Traffic: 613 (year 2032),  Design Load: HS 20,  Features Intersected: I-39/US 51,  Facility Carried by Structure: CH 4 (500 N)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.711,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 50.6m (166.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 620054,  Location: 3 MI S OF IL 17 (Lat: 40.984269,  Lng: -89.056281),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 125 (year 2019),  Truck Traffic: 17%,  Average Future Daily Traffic: 195 (year 2032),  Design Load: HS 20,  Features Intersected: I-39/US 51,  Facility Carried by Structure: FAS 369 (400 N)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.306,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 50.6m (166.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 620055,  Location: 5 MI S OF IL 17 (Lat: 40.955039,  Lng: -89.056369),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 75 (year 2019),  Truck Traffic: 27%,  Average Future Daily Traffic: 139 (year 2032),  Design Load: HS 20,  Features Intersected: I-39/US 51,  Facility Carried by Structure: TR 121A (200 N)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.771,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 50.5m (165.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Very good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 620053,  Location: 2.02 MI S 0F ILL 17 (Lat: 40.998831,  Lng: -89.056139),  Route carried "under" structure: Interstate 39,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 17,900 (year 2021),  Truck Traffic: 35%,  Features Intersected: I-39/US 51,  Facility Carried by Structure: CH 4 (500 N)
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 54.233,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.6m (166.0ft)

Find on map >>   Show street view

Structure Number: 620054,  Location: 3 MI S OF IL 17 (Lat: 40.984269,  Lng: -89.056281),  Route carried "under" structure: Interstate 39,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 17,900 (year 2021),  Truck Traffic: 35%,  Features Intersected: I-39/US 51,  Facility Carried by Structure: FAS 369 (400 N)
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 52.737,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.6m (166.0ft)

Find on map >>   Show street view

Structure Number: 620055,  Location: 5 MI S OF IL 17 (Lat: 40.955039,  Lng: -89.056369),  Route carried "under" structure: Interstate 39,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 17,900 (year 2021),  Truck Traffic: 35%,  Features Intersected: I-39/US 51,  Facility Carried by Structure: TR 121A (200 N)
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 49.502,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.5m (165.7ft)

Discuss Rutland, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.