  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 151ft / 46.0mTotal length
  • $728,000Total costs
  • 67,112Total average daily traffic
  • 5,873Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rothbury
  • No street view available for this location

New bridges in Rothbury, MI - historical statistics
  • New bridges - historical statistics
  • 131970-1979
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Rothbury, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 42.9%Good
  • 42.9%Satisfactory
  • 14.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Very good
  • 57.1%Good
  • 28.6%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 42.9%Good
  • 57.1%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Good
  • 50.0%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Very good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 8325,  Location: 2.5 MI S OF ROTHBURY (Lat: 43.476103,  Lng: -86.343967),  Route carried "on" structure: US 31,  Year Built: 1974,  Status: Open,  Structure Length: 5.39m (17.68ft),  Average Daily Traffic: 6,360 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,766 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HART-MONTAGUE TRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.653,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 154,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $181,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $163,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8326,  Location: 2.5 MI S OF ROTHBURY (Lat: 43.476642,  Lng: -86.343981),  Route carried "on" structure: US 31,  Year Built: 1974,  Status: Open,  Structure Length: 5.30m (17.39ft),  Average Daily Traffic: 6,360 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,766 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HART-MONTAGUE TRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.748,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 154,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.8m (61.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $179,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $161,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8328,  Location: 0.5 MI SW OF ROTHBURY (Lat: 43.493575,  Lng: -86.370156),  Route carried "on" structure: County highway 6429,  Year Built: 1974,  Status: Open,  Structure Length: 11.46m (37.60ft),  Average Daily Traffic: 550 (year 1988),  Average Future Daily Traffic: 500 (year 1977),  Design Load: H 20,  Features Intersected: US-31,  Facility Carried by Structure: WEBSTER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.747,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 40.2m (131.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $359,000,  Roadway Improvement Cost: $22,000,  Total Project Cost: $261,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8329,  Location: 1 MI W OF ROTHBURY (Lat: 43.508017,  Lng: -86.373522),  Route carried "on" structure: County highway 6410,  Year Built: 1973,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 9.72m (31.89ft),  Average Daily Traffic: 2,500 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,090 (year 2033),  Design Load: H 20,  Features Intersected: US-31,  Facility Carried by Structure: WINSTON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.605,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.1m (118.4ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 833,  Location: 2 MI SW OF NEW ERA (Lat: 43.533611,  Lng: -86.385147),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 60 (year 2007),  Average Future Daily Traffic: 66 (year 2022),  Design Load: H 20,  Features Intersected: US-31 SB,  Facility Carried by Structure: PARK RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.686,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.3m (151.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 65.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8331,  Location: 2 MI SW OF NEW ERA (Lat: 43.533564,  Lng: -86.383689),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 60 (year 1988),  Average Future Daily Traffic: 69 (year 2008),  Design Load: H 20,  Features Intersected: US-31 NB,  Facility Carried by Structure: PARK RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.805,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.3m (151.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 91.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $151,000,  Roadway Improvement Cost: $8,000,  Total Project Cost: $93,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8333,  Location: 1.5 MI S OF ROTHBURY (Lat: 43.477967,  Lng: -86.347372),  Route carried "on" structure: US 31,  Year Built: 1974,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 6,360 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,766 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: OCEANA DRIVE (OLD US-31)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.061,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 154,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 86.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.35m (10.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $81,000,  Roadway Improvement Cost: $4,000,  Total Project Cost: $50,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 12967,  Location: GRANT TWP SEC 27 (Lat: 43.496867,  Lng: -86.328142),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 270 (year 2004),  Truck Traffic: 2%,  Average Future Daily Traffic: 350 (year 2024),  Design Load: HS 20,  Features Intersected: CARLTON CREEK,  Facility Carried by Structure: 92ND AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.056,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 13151,  Location: 0.25 MI W OF 72ND AVE (Lat: 43.472167,  Lng: -86.381364),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 150 (year 2005),  Truck Traffic: 2%,  Average Future Daily Traffic: 200 (year 2025),  Design Load: HS 20,  Features Intersected: FLOWER CREEK,  Facility Carried by Structure: SKEELS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.879,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.7m (25.3ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.4m (24.3ft),  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8327,  Location: 1.5 MI S OF ROTHBURY (Lat: 43.477594,  Lng: -86.347358),  Route carried "under" structure: Alternate US 31,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 4,900 (year 1995),  Truck Traffic: 5%,  Features Intersected: OCEANA DRIVE (OLD US-31)
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.665,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 8328,  Location: 0.5 MI SW OF ROTHBURY (Lat: 43.493575,  Lng: -86.370156),  Route carried "under" structure: US 31,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 12,720 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-31,  Facility Carried by Structure: WEBSTER RD
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 3.694,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.2m (131.9ft)

Find on map >>   Show street view

Structure Number: 8329,  Location: 1 MI W OF ROTHBURY (Lat: 43.508017,  Lng: -86.373522),  Route carried "under" structure: US 31,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2013),  Truck Traffic: 10%,  Features Intersected: US-31,  Facility Carried by Structure: WINSTON RD
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 5.327,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.1m (118.4ft)

Find on map >>   Show street view

Structure Number: 833,  Location: 2 MI SW OF NEW ERA (Lat: 43.533611,  Lng: -86.385147),  Route carried "under" structure: US 31,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 5,611 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-31 SB,  Facility Carried by Structure: PARK RD
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 8.520,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.3m (151.9ft)

Find on map >>   Show street view

Structure Number: 8331,  Location: 2 MI SW OF NEW ERA (Lat: 43.533564,  Lng: -86.383689),  Route carried "under" structure: US 31,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 5,611 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-31 NB,  Facility Carried by Structure: PARK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.472,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.3m (151.9ft)

Find on map >>   Show street view

Structure Number: 8333,  Location: 1.5 MI S OF ROTHBURY (Lat: 43.477967,  Lng: -86.347372),  Route carried "under" structure: Alternate US 31,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 4,600 (year 1995),  Truck Traffic: 12%,  Features Intersected: OCEANA DRIVE (OLD US-31)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.705,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)