Bridge Statistics for Palmerton, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 154ft / 47.2mTotal length
  • $767,000Total costs
  • 123,692Total average daily traffic
  • 6,384Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Palmerton
  • No street view available for this location

New bridges in Palmerton, PA - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 11920-1929
  • 11930-1939
  • 11950-1959
  • 91960-1969
  • 11970-1979
  • 22000-2009
Reconstructed bridges in Palmerton, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 11990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Palmerton, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 10.0%Very good
  • 20.0%Good
  • 50.0%Satisfactory
  • 10.0%Fair
  • 10.0%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.0%Very good
  • 10.0%Good
  • 20.0%Satisfactory
  • 40.0%Fair
  • 10.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 20.0%Good
  • 10.0%Satisfactory
  • 60.0%Fair
  • 10.0%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Good
  • 12.5%Satisfactory
  • 25.0%Fair
  • 37.5%Poor
Find on map >>   Show street view

Structure Number: 901,  Location: 0.5 MI.S.OF PALMERTON (Lat: 40.795669,  Lng: -75.616833),  Route carried "on" structure: State highway 248,  Year Built: 1962,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 23,146 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 30,432 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK SOUTHERN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.040,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Inventory Rating: 62.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.40m (11.15ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $18,000,  Roadway Improvement Cost: $52,000,  Total Project Cost: $240,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 9013,  Location: CANTILEVER (Lat: 40.789017,  Lng: -75.608647),  Route carried "on" structure: State highway 248,  Year Built: 1962,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 29.26m (96.00ft),  Average Daily Traffic: 11,506 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,569 (year 2032),  Design Load: HS 20,  Features Intersected: PA 248 EB(LR 163)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.857,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 8 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 29.70m (97.44ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 9055,  Location: PALMERTON-DELAWARE AVE. (Lat: 40.798819,  Lng: -75.617231),  Route carried "on" structure: State highway ,  Year Built: 1962,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 15,759 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 19,744 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK/SOUTHERN RR,  Facility Carried by Structure: SR 2002(APPL.1461)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.50m (14.76ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 9058,  Location: PALMERTON/AQUASHICOLA (Lat: 40.809969,  Lng: -75.591908),  Route carried "on" structure: State highway ,  Year Built: 1922,  Status: Posted for load,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 10,448 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,582 (year 2032),  Design Load: HS 20,  Features Intersected: LITTLE AQUASHICOLA CREEK,  Facility Carried by Structure: SR 2002(APPL.1461)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.049,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Poor,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2021,  Other Special Inspection Date: Febuary 2021,  Bridge Improvement Cost: $5,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $62,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9066,  Location: AQUASHICOLA,FIRELINE RD. (Lat: 40.814933,  Lng: -75.594600),  Route carried "on" structure: State highway ,  Year Built: 1960,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 1,611 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,578 (year 2032),  Design Load: HS 20,  Features Intersected: MILL CREEK,  Facility Carried by Structure: SR 2004 (LR 13014)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.214,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $117,000,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 9068,  Location: .75 M. W.OF LITTLE GAP (Lat: 40.834594,  Lng: -75.534078),  Route carried "on" structure: State highway ,  Year Built: 1978,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 1,165 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,486 (year 2032),  Design Load: HS 20,  Features Intersected: HUNTER CREEK,  Facility Carried by Structure: SR 2004 (LR 13014)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.983,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 912,  Location: NW OF LITTLE GAP (Lat: 40.841969,  Lng: -75.540042),  Route carried "on" structure: City street ,  Year Built: 1955,  Status: Posted for load,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 90 (year 1989),  Average Future Daily Traffic: 126 (year 2009),  Design Load: HS 20,  Features Intersected: HUNTERS CREEK,  Facility Carried by Structure: SUMMER MTN. RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2020,  Other Special Inspection Date: July 2021,  Bridge Improvement Cost: $8,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $113,000
Find on map >>   Show street view

Structure Number: 9121,  Location: LITTLE GAP (Lat: 40.832014,  Lng: -75.522544),  Route carried "on" structure: City street ,  Year Built: 1932,  Status: Posted for load,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 750 (year 1990),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,500 (year 2030),  Design Load: H 10,  Features Intersected: HUNTERS CREEK,  Facility Carried by Structure: COVERED BRG RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.3m (17.4ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 20.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2020,  Other Special Inspection Date: July 2021,  Bridge Improvement Cost: $10,000,  Roadway Improvement Cost: $31,000,  Total Project Cost: $140,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9122,  Location: LITTLE GAP COVERED BRIDGE (Lat: 40.831383,  Lng: -75.522450),  Route carried "on" structure: City street ,  Year Built: 1880,  Year Reconstructed: 1987,  Status: Posted for load,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 750 (year 1979),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,350 (year 2009),  Design Load: H 15,  Features Intersected: PRINCESS CREEK,  Facility Carried by Structure: COVER BRIDGE RD
Minimum Vertical Clearance: 2.74m (8.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 4.6m (15.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Very good,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 3.10m (10.17ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: December 2020,  Critical Feature Inspection Date: December 2020,  Other Special Inspection Date: December 2021,  Bridge Improvement Cost: $7,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $95,000,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 40989,  Location: .25 MI.N.OF LEHIGH GAP (Lat: 40.792964,  Lng: -75.612328),  Route carried "on" structure: State highway 248,  Year Built: 2000,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 23,146 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 30,432 (year 2032),  Design Load: HS 20,  Features Intersected: AQUASHICOLA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.840,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 22.8m (74.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.50m (11.48ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 44954,  Location: Lower Smith Gap Rd. (Lat: 40.822547,  Lng: -75.525814),  Route carried "on" structure: State highway ,  Year Built: 2008,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 1,161 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,159 (year 2032),  Design Load: HL 93,  Features Intersected: Buckwha Creek,  Facility Carried by Structure: SR 2006
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.335,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9008,  Location: PA.248 OVER DELAWARE AVE. (Lat: 40.797244,  Lng: -75.619958),  Route carried "under" structure: State highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 4,298 (year 2022),  Truck Traffic: 9%,  Features Intersected: SR 2002 (APPL.1461),  Facility Carried by Structure: PA 248 (LR 163)
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 9008,  Location: PA.248 OVER DELAWARE AVE. (Lat: 40.797244,  Lng: -75.619958),  Route carried "under" structure: State highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 8,171 (year 2020),  Truck Traffic: 8%,  Features Intersected: SR 2002 (APPL.1461),  Facility Carried by Structure: PA 248 (LR 163)
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 9008,  Location: PA.248 OVER DELAWARE AVE. (Lat: 40.797244,  Lng: -75.619958),  Route carried "under" structure: State highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 7,588 (year 2020),  Truck Traffic: 6%,  Features Intersected: SR 2002 (APPL.1461),  Facility Carried by Structure: PA 248 (LR 163)
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 9008,  Location: PA.248 OVER DELAWARE AVE. (Lat: 40.797244,  Lng: -75.619958),  Route carried "under" structure: State highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 2,463 (year 2022),  Truck Traffic: 9%,  Features Intersected: SR 2002 (APPL.1461),  Facility Carried by Structure: PA 248 (LR 163)
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 9013,  Location: CANTILEVER (Lat: 40.789017,  Lng: -75.608647),  Route carried "under" structure: State highway 248,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 11,640 (year 2022),  Truck Traffic: 4%,  Features Intersected: PA 248 EB(LR 163)
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 9.840,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 6.1m (20.0ft)

Discuss Palmerton, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.