Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Ogden, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 72ft / 22.1mTotal length
  • 56,575Total average daily traffic
  • 16,269Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Ogden
  • No street view available for this location

New bridges in Ogden, IL - historical statistics
  • New bridges - historical statistics
  • 21950-1959
  • 11960-1969
  • 11970-1979
  • 21980-1989
  • 21990-1999
  • 32000-2009
Average Bridge Daily Traffic in Ogden, IL
Average Bridge Truck Traffic in Ogden, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 42.9%Good
  • 57.1%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 42.9%Good
  • 57.1%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 28.6%Very good
  • 28.6%Good
  • 28.6%Satisfactory
  • 14.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 57.1%Very good
  • 14.3%Good
  • 28.6%Satisfactory
Find on map >>   Show street view

Structure Number: 100095,  Location: 3.5 MI S OF ROYAL (Lat: 40.142025,  Lng: -87.959828),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Open,  Structure Length: 0.84m (2.76ft),  Average Daily Traffic: 600 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 959 (year 2032),  Design Load: HS 15,  Features Intersected: STREAM,  Facility Carried by Structure: FAS 518 (CH 22)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.649,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.0m (26.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 100277,  Location: N EDGE OF OGDEN (Lat: 40.119703,  Lng: -87.958828),  Route carried "on" structure: Other road ,  Year Built: 2008,  Status: Open,  Structure Length: 6.68m (21.92ft),  Average Daily Traffic: 1,950 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,707 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: I-74,  Facility Carried by Structure: FAS 518 (CH 22)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.0m (108.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 102023,  Location: 0.5 MI N OF OGDEN (Lat: 40.127306,  Lng: -87.958883),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 600 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 959 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: STREAM,  Facility Carried by Structure: FAS 518(CH 22)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.290,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 104055,  Location: 1 MI NE OGDEN (Lat: 40.127200,  Lng: -87.950028),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 150 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 169 (year 2032),  Design Load: HS 15,  Features Intersected: STREAM,  Facility Carried by Structure: TR 181 A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.886,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 104432,  Location: 2 MI NW OF OGDEN (Lat: 40.131256,  Lng: -87.977986),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.36m (4.46ft),  Average Daily Traffic: 25 (year 2021),  Average Future Daily Traffic: 67 (year 2032),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: TR 326 A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.191,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 920146,  Location: 1 MI W OF ILL 49 (Lat: 40.123144,  Lng: -87.921169),  Route carried "on" structure: County highway ,  Year Built: 1959,  Status: Open,  Structure Length: 5.75m (18.86ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 61 (year 2032),  Design Load: HS 15,  Features Intersected: I-74,  Facility Carried by Structure: TR 8 A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.076,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 923328,  Location: 2.5 MI NW FITHIAN (Lat: 40.126986,  Lng: -87.921189),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 61 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: TR 8 A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.658,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 923329,  Location: 2.5 MI NW FITHIAN (Lat: 40.127439,  Lng: -87.920811),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 103 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: TR 261
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.658,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 923449,  Location: 4 MI NW FITHIAN (Lat: 40.144392,  Lng: -87.940975),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 61 (year 2032),  Design Load: HS 20,  Features Intersected: STONY CREEK,  Facility Carried by Structure: TR 6
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.932,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.4m (50.5ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 100277,  Location: N EDGE OF OGDEN (Lat: 40.119839,  Lng: -87.958831),  Route carried "under" structure: Interstate 74,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 26,500 (year 2021),  Truck Traffic: 30%,  Features Intersected: I-74,  Facility Carried by Structure: FAS 518 (CH 22)
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 319.591,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.0m (108.3ft)

Find on map >>   Show street view

Structure Number: 920146,  Location: 1 MI W OF ILL 49 (Lat: 40.122850,  Lng: -87.921169),  Route carried "under" structure: Interstate 74,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 26,500 (year 2021),  Truck Traffic: 30%,  Features Intersected: I-74,  Facility Carried by Structure: TR 8 A
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 322.842,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Discuss Ogden, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.