Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Morrison, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 19Number of bridges
  • 262ft / 80.3mTotal length
  • $2,348,000Total costs
  • 318,410Total average daily traffic
  • 9,925Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Morrison
  • No street view available for this location

New bridges in Morrison, CO - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 41930-1939
  • 11940-1949
  • 21960-1969
  • 61980-1989
  • 21990-1999
  • 32000-2009
Average Bridge Daily Traffic in Morrison, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Good
  • 41.7%Satisfactory
  • 33.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 8.3%Good
  • 41.7%Satisfactory
  • 50.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 8.3%Good
  • 75.0%Satisfactory
  • 16.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Very good
  • 33.3%Good
  • 16.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 66.7%Satisfactory
Find on map >>   Show street view

Structure Number: F-16-AO,  Location: IN MORRISON (Lat: 39.653647,  Lng: -105.195233),  Route carried "on" structure: State highway 8A,  Year Built: 1934,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 4,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,640 (year 2040),  Design Load: H 15,  Features Intersected: DRAW,  Facility Carried by Structure: SH 8 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.663,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: F-16-AW,  Location: 0.75 MI S OF MORRISON (Lat: 39.641500,  Lng: -105.193600),  Route carried "on" structure: State highway 8A,  Year Built: 1935,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 4,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,640 (year 2040),  Design Load: H 15,  Features Intersected: STRAINS GULCH,  Facility Carried by Structure: SH 8 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.261,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F-16-AX,  Location: SOUTH OF MORRISON (Lat: 39.639642,  Lng: -105.193486),  Route carried "on" structure: State highway 8A,  Year Built: 1935,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 4,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,640 (year 2040),  Design Load: H 15,  Features Intersected: DRAW,  Facility Carried by Structure: SH 8 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.057,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 50.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F-16-FB,  Location: 2 MI SOUTH OF MORRISON (Lat: 39.624100,  Lng: -105.192500),  Route carried "on" structure: State highway 8A,  Year Built: 1967,  Status: Open,  Structure Length: 5.64m (18.50ft),  Average Daily Traffic: 3,800 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 4,180 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US 285 ML,  Facility Carried by Structure: SH 8 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.317,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F-16-LB,  Location: 2 MI N OF JCT US 285 (Lat: 39.661742,  Lng: -105.184683),  Route carried "on" structure: State highway 470A,  Year Built: 1988,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 70,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 93,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: E. FR ROAD/ROONEY ROAD,  Facility Carried by Structure: SH470 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.961,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.9m (107.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.0m (85.3ft),  Curb-To-Curb Width: 32.9m (107.9ft),  Out-to-Out Width: 34.6m (113.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F-16-LC,  Location: MORRISON RD. INTERCHANGE (Lat: 39.653972,  Lng: -105.181258),  Route carried "on" structure: State highway 470A,  Year Built: 1989,  Status: Open,  Structure Length: 23.32m (76.51ft),  Average Daily Traffic: 35,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 46,900 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SH 8, BEAR CREEK,  Facility Carried by Structure: SH 470 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.883,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 67.0m (219.8ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Inventory Rating: 64.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: F-16-LD,  Location: MORRISON RD. INTERCHANGE (Lat: 39.653892,  Lng: -105.181511),  Route carried "on" structure: State highway 470A,  Year Built: 1989,  Status: Open,  Structure Length: 23.31m (76.48ft),  Average Daily Traffic: 35,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 46,900 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SH 8, BEAR CREEK,  Facility Carried by Structure: SH 470 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.891,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 67.1m (220.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Inventory Rating: 66.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-LF,  Location: SW CRNR OF MORRISON RD.IN (Lat: 39.652422,  Lng: -105.181603),  Route carried "on" structure: Ramp State highway 470A,  Year Built: 1989,  Status: Open,  Structure Length: 7.47m (24.51ft),  Average Daily Traffic: 39,500 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 52,140 (year 2040),  Design Load: HS 20,  Features Intersected: BEAR CREEK R,  Facility Carried by Structure: RAMP TO SH 470 EBD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.481,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 41.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-SA,  Location: AT INDIAN HILLS RD INTERS (Lat: 39.615881,  Lng: -105.232106),  Route carried "on" structure: US 285D,  Year Built: 1993,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 27,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 34,020 (year 2040),  Design Load: HS 20,  Features Intersected: PARMALEE GULCH,  Facility Carried by Structure: US 285 ML & RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 135.063,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.8m (101.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2019
Find on map >>   Show street view

Structure Number: F-16-SH,  Location: 0.3 MI E OF JCT SH 8 (Lat: 39.625714,  Lng: -105.188950),  Route carried "on" structure: US 285D,  Year Built: 2008,  Status: Open,  Structure Length: 2.93m (9.61ft),  Average Daily Traffic: 39,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 50,700 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: WILLOW SPRINGS ROAD,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 139.445,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.7m (81.0ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.5m (93.5ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.97m (13.02ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $1,565,000,  Roadway Improvement Cost: $157,000,  Total Project Cost: $2,348,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-SR,  Location: IN MORRISON (Lat: 39.653344,  Lng: -105.195200),  Route carried "on" structure: State highway 8A,  Year Built: 1993,  Status: Open,  Structure Length: 4.50m (14.76ft),  Average Daily Traffic: 4,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,640 (year 2040),  Design Load: HS 20,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: SH 8 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.579,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 65.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-17-12A,  Location: .2 MI SOUTH OF US285 (Lat: 39.622536,  Lng: -105.187792),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,497 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,721 (year 2041),  Design Load: HS 20,  Features Intersected: TURKEY CREEK,  Facility Carried by Structure: WILLOW SPRINGS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.842,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: F-18-68,  Location: SODA LAKES RD S OFSH 8 (Lat: 39.651328,  Lng: -105.184100),  Route carried "on" structure: County highway ,  Year Built: 1938,  Status: Open,  Structure Length: 1.81m (5.94ft),  Average Daily Traffic: 291 (year 2021),  Average Future Daily Traffic: 335 (year 2041),  Features Intersected: BEAR CREEK,  Facility Carried by Structure: SODA LAKES ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.596,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: MORR-CANON ST,  Location: AT INTER WITH SH 8 (Lat: 39.654250,  Lng: -105.194583),  Route carried "on" structure: City street ,  Year Built: 1945,  Status: Posted for load,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 102 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 117 (year 2041),  Features Intersected: BEAR CREEK,  Facility Carried by Structure: CANON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.013,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.9m (22.6ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: MORR-PARK AVE,  Location: AT INTER. WITH SH 8 (Lat: 39.654139,  Lng: -105.192892),  Route carried "on" structure: City street ,  Year Built: 1926,  Year Reconstructed: 2013,  Status: Posted for load,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 220 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 253 (year 2041),  Design Load: HS 20,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: PARK AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.049,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 3.7m (12.1ft),  Out-to-Out Width: 4.3m (14.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 10.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 6.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: F-16-FB,  Location: 2 MI SOUTH OF MORRISON (Lat: 39.624100,  Lng: -105.192500),  Route carried "under" structure: US 285D,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 29,000 (year 2011),  Truck Traffic: 7%,  Features Intersected: US 285 ML,  Facility Carried by Structure: SH 8 ML
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 399.631,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.1m (56.1ft)

Find on map >>   Show street view

Structure Number: F-16-LC,  Location: MORRISON RD. INTERCHANGE (Lat: 39.653972,  Lng: -105.181258),  Route carried "under" structure: State highway 8A,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2011),  Truck Traffic: 3%,  Features Intersected: SH 8, BEAR CREEK,  Facility Carried by Structure: SH 470 ML NBND
Minimum Vertical Clearance: 6.02m (19.75ft),  Kilometerpoint: 4.639,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 67.0m (219.8ft)

Find on map >>   Show street view

Structure Number: F-16-LD,  Location: MORRISON RD. INTERCHANGE (Lat: 39.653892,  Lng: -105.181511),  Route carried "under" structure: State highway 8A,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2011),  Truck Traffic: 3%,  Features Intersected: SH 8, BEAR CREEK,  Facility Carried by Structure: SH 470 ML SBND
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 4.637,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 67.1m (220.1ft)

Find on map >>   Show street view

Structure Number: F-16-SH,  Location: 0.3 MI E OF JCT SH 8 (Lat: 39.625714,  Lng: -105.188950),  Route carried "under" structure: _,  Year Built: 2008,  Structure Length: 0. m,  Features Intersected: WILLOW SPRINGS ROAD,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.5m (93.5ft)

Discuss Morrison, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.