Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Manton, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 226ft / 69.5mTotal length
  • 69,060Total average daily traffic
  • 3,768Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Manton
  • No street view available for this location

New bridges in Manton, MI - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11960-1969
  • 21990-1999
  • 182000-2009
Average Bridge Daily Traffic in Manton, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 8.3%Very good
  • 75.0%Good
  • 16.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.1%Very good
  • 53.8%Good
  • 23.1%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.7%Very good
  • 46.2%Good
  • 38.5%Satisfactory
  • 7.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 28.6%Very good
  • 28.6%Good
  • 42.9%Satisfactory
Find on map >>   Show street view

Structure Number: 2043,  Location: 3.3 MI N OF M-72 (Lat: 44.704431,  Lng: -84.699206),  Route carried "on" structure: Interstate 75,  Year Built: 1961,  Status: Open,  Structure Length: 3.01m (9.88ft),  Average Daily Traffic: 7,158 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 8,178 (year 2018),  Design Load: HS 20,  Features Intersected: LEWISTON GRADE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.876,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 53,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.0m (32.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 2094,  Location: 1.3 MI E NAHMA JUNCTION (Lat: 45.893292,  Lng: -86.683717),  Route carried "on" structure: US 2,  Year Built: 1936,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 3,462 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 6,463 (year 2018),  Design Load: H 15,  Features Intersected: BULL RUN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 76.509,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 134,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 12572,  Location: IN MANTON (Lat: 44.403797,  Lng: -85.393153),  Route carried "on" structure: State highway 42,  Year Built: 2004,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 2,850 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,434 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CEDAR CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.282,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 112,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12579,  Location: SECTION 20/29 T24N R9W (Lat: 44.454111,  Lng: -85.426186),  Route carried "on" structure: County highway 8380,  Year Built: 1994,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 440 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 800 (year 2025),  Design Load: HS 20,  Features Intersected: MANTON CREEK,  Facility Carried by Structure: NO 10 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.324,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Aluminum,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1258,  Location: SECTION 33 T24N R9W (Lat: 44.425150,  Lng: -85.408281),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 980 (year 2005),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,770 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: MANTON CREEK,  Facility Carried by Structure: NO 14 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.792,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12584,  Location: SECTION 29/32 T24N R9W (Lat: 44.439742,  Lng: -85.425725),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 120 (year 2005),  Average Future Daily Traffic: 210 (year 2025),  Design Load: HS 20,  Features Intersected: MANTON CREEK,  Facility Carried by Structure: NO 12 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.403,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 27.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Wood or Timber
Find on map >>   Show street view

Structure Number: 12585,  Location: SECTION 32/33 T24N R9W (Lat: 44.434117,  Lng: -85.418172),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 256 (year 2005),  Truck Traffic: 4%,  Average Future Daily Traffic: 460 (year 2025),  Features Intersected: MANTON CREEK,  Facility Carried by Structure: NO 41 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.535,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 13029,  Location: 3 MI N OF CADILLAC (Lat: 44.372431,  Lng: -85.397664),  Route carried "on" structure: US 131,  Year Built: 2002,  Status: Open,  Structure Length: 14.49m (47.54ft),  Average Daily Traffic: 3,350 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 3,853 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: US-131
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 17.773,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 383,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13031,  Location: 1 MI E OF MANTON (Lat: 44.403819,  Lng: -85.381083),  Route carried "on" structure: US 131,  Year Built: 2002,  Status: Open,  Structure Length: 6.07m (19.91ft),  Average Daily Traffic: 3,575 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 8,750 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: M-42 (16 1/2 RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.017,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 383,  Subroute: 27),  Owner: State Highway Agency,  Approaching Roadway Width: 12.9m (42.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.4m (119.4ft),  Curb-To-Curb Width: 21.2m (69.6ft),  Out-to-Out Width: 22.2m (72.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13032,  Location: 1 MI E OF MANTON (Lat: 44.403825,  Lng: -85.381614),  Route carried "on" structure: US 131,  Year Built: 2002,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 3,575 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 8,750 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: M-42 (16 1/2 RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.049,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 383,  Subroute: 28),  Owner: State Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.0m (114.8ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13033,  Location: 1 MI E OF MANTON (Lat: 44.410958,  Lng: -85.380411),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 8.94m (29.33ft),  Average Daily Traffic: 150 (year 2000),  Truck Traffic: 9%,  Average Future Daily Traffic: 173 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: US-131,  Facility Carried by Structure: NO. 16 RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 27.003,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.6m (41.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.7m (146.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 87.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13034,  Location: 1 MI NE OF MANTON (Lat: 44.428853,  Lng: -85.388831),  Route carried "on" structure: US 131,  Year Built: 2002,  Status: Open,  Structure Length: 3.39m (11.12ft),  Average Daily Traffic: 3,535 (year 2007),  Average Future Daily Traffic: 4,065 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: NO 12 3/4 RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 32.965,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 383,  Subroute: 28),  Owner: State Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.9m (111.2ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13035,  Location: 1 MI NE OF MANTON (Lat: 44.428853,  Lng: -85.388233),  Route carried "on" structure: US 131,  Year Built: 2002,  Status: Open,  Structure Length: 3.39m (11.12ft),  Average Daily Traffic: 3,535 (year 2007),  Average Future Daily Traffic: 4,065 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: NO 12 3/4 RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 32.933,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 383,  Subroute: 27),  Owner: State Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.9m (111.2ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13036,  Location: 2 MI N OF MANTON (Lat: 44.454253,  Lng: -85.395067),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 8.88m (29.13ft),  Average Daily Traffic: 95 (year 2001),  Average Future Daily Traffic: 109 (year 2021),  Design Load: HS 25 or greater,  Features Intersected: US-131,  Facility Carried by Structure: NO. 10 RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.801,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.4m (145.7ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13444,  Location: 5.7 MI N OF MANTON (Lat: 44.484450,  Lng: -85.406358),  Route carried "on" structure: US 131,  Year Built: 2009,  Status: Open,  Structure Length: 10.21m (33.50ft),  Average Daily Traffic: 8,450 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 10,478 (year 2018),  Design Load: Greater than HL93,  Features Intersected: MANISTEE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 39.517,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 383,  Subroute: 27),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.6m (110.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 75.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13029,  Location: 3 MI N OF CADILLAC (Lat: 44.372431,  Lng: -85.397664),  Route carried "under" structure: US 131,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 7,150 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-131
Minimum Vertical Clearance: 5.97m (19.59ft),  Kilometerpoint: 26.116,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.2m (145.0ft)

Find on map >>   Show street view

Structure Number: 13031,  Location: 1 MI E OF MANTON (Lat: 44.403819,  Lng: -85.381083),  Route carried "under" structure: State highway 42,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 3,223 (year 2007),  Features Intersected: M-42 (16 1/2 RD),  Facility Carried by Structure: US-131 NB
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 6.244,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.4m (119.4ft)

Find on map >>   Show street view

Structure Number: 13032,  Location: 1 MI E OF MANTON (Lat: 44.403825,  Lng: -85.381614),  Route carried "under" structure: State highway 42,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 2,850 (year 2007),  Features Intersected: M-42 (16 1/2 RD),  Facility Carried by Structure: US-131 SB
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 6.203,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.0m (114.8ft)

Find on map >>   Show street view

Structure Number: 13033,  Location: 1 MI E OF MANTON (Lat: 44.410958,  Lng: -85.380411),  Route carried "under" structure: US 131,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 7,070 (year 2007),  Features Intersected: US-131,  Facility Carried by Structure: NO. 16 RD
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 30.812,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.7m (146.7ft)

Find on map >>   Show street view

Structure Number: 13034,  Location: 1 MI NE OF MANTON (Lat: 44.428853,  Lng: -85.388831),  Route carried "under" structure: County highway ,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 83 (year 2001),  Features Intersected: NO 12 3/4 RD,  Facility Carried by Structure: US-131 SB
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.763,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.9m (111.2ft)

Find on map >>   Show street view

Structure Number: 13035,  Location: 1 MI NE OF MANTON (Lat: 44.428853,  Lng: -85.388233),  Route carried "under" structure: County highway ,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 83 (year 2001),  Features Intersected: NO 12 3/4 RD,  Facility Carried by Structure: US-131 NB
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.811,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.9m (111.2ft)

Find on map >>   Show street view

Structure Number: 13036,  Location: 2 MI N OF MANTON (Lat: 44.454253,  Lng: -85.395067),  Route carried "under" structure: US 131,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 7,070 (year 2007),  Features Intersected: US-131,  Facility Carried by Structure: NO. 10 RD
Minimum Vertical Clearance: 5.94m (19.49ft),  Kilometerpoint: 35.861,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.4m (145.7ft)

Discuss Manton, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.