Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Luzerne, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 141ft / 42.5mTotal length
  • $4,560,000Total costs
  • 185,420Total average daily traffic
  • 8,785Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Luzerne
  • No street view available for this location

New bridges in Luzerne, PA - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 101980-1989
  • 12010-2019
Average Bridge Daily Traffic in Luzerne, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 37.5%Good
  • 12.5%Satisfactory
  • 12.5%Fair
  • 12.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Excellent
  • 37.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
  • 12.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.5%Very good
  • 12.5%Good
  • 25.0%Satisfactory
  • 37.5%Fair
  • 12.5%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Good
  • 25.0%Fair
  • 50.0%Poor
Find on map >>   Show street view

Structure Number: 23885,  Location: LUZERNE BO .2 M N SR 1015 (Lat: 41.277769,  Lng: -75.888617),  Route carried "on" structure: State highway 309,  Year Built: 1980,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 40,149 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 55,586 (year 2032),  Design Load: HS 20,  Features Intersected: LUZ CO RAIL AUTHORITY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.722,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 29.9m (98.1ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.80m (15.75ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $42,000,  Roadway Improvement Cost: $123,000,  Total Project Cost: $564,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23886,  Location: LUZ BORO OVER VAUGHN ST (Lat: 41.278331,  Lng: -75.890000),  Route carried "on" structure: State highway 309,  Year Built: 1980,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 40,149 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 55,586 (year 2032),  Design Load: HS 20,  Features Intersected: VAUGHN ST, ABANDONED RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.398,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 32 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 30.3m (99.4ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $61,000,  Roadway Improvement Cost: $181,000,  Total Project Cost: $828,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23887,  Location: LUZERNE BORO OVER SR 1013 (Lat: 41.279856,  Lng: -75.894817),  Route carried "on" structure: State highway 309,  Year Built: 1980,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 15.76m (51.71ft),  Average Daily Traffic: 34,500 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 45,697 (year 2032),  Design Load: HS 20,  Features Intersected: SR 1013 UNION STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.398,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 35 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 24.2m (79.4ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 15.80m (51.84ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $130,000,  Roadway Improvement Cost: $382,000,  Total Project Cost: $1,752,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 23891,  Location: LUZERNE BORO OVER SR 8039 (Lat: 41.287556,  Lng: -75.904178),  Route carried "on" structure: State highway 309,  Year Built: 1980,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 34,500 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 45,697 (year 2032),  Design Load: HS 20,  Features Intersected: RAMP A; SR 8039
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.081,  Lanes on structure: 4,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 34 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 24.0m (78.7ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.30m (17.39ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: November 2020,  Other Special Inspection Date: May 2021,  Bridge Improvement Cost: $18,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $238,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23966,  Location: LUZERNE BORO JCT SR 1013 (Lat: 41.284756,  Lng: -75.898697),  Route carried "on" structure: State highway ,  Year Built: 1989,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 3,494 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,640 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: TOBY CREEK,  Facility Carried by Structure: SR 1008
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Poor,  Operating Rating: 97.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 3.40m (11.15ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23978,  Location: LUZERNE BO .1 M N TR 309 (Lat: 41.281422,  Lng: -75.895511),  Route carried "on" structure: State highway ,  Year Built: 1939,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 10,092 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,872 (year 2032),  Design Load: H 20,  Features Intersected: TOBYS CREEK,  Facility Carried by Structure: SR 1013
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.710,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 6 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Poor,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.80m (15.75ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: September 2020,  Other Special Inspection Date: September 2021,  Bridge Improvement Cost: $85,000,  Roadway Improvement Cost: $249,000,  Total Project Cost: $1,143,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 24471,  Location: AT SR 1013 INTERSECT (Lat: 41.282081,  Lng: -75.895533),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 2,400 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,200 (year 2036),  Design Load: HS 20,  Features Intersected: TOBY CREEK,  Facility Carried by Structure: BUCKINGHAM ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $3,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $35,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 47322,  Location: LUZERNE BORO AT EVANS ST (Lat: 41.280797,  Lng: -75.895433),  Route carried "on" structure: State highway ,  Year Built: 2012,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 6,129 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,116 (year 2032),  Design Load: HL 93,  Features Intersected: TOBY CREEK,  Facility Carried by Structure: SR 1054
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23886,  Location: LUZ BORO OVER VAUGHN ST (Lat: 41.278331,  Lng: -75.890000),  Route carried "under" structure: City street ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2004),  Truck Traffic: 10%,  Features Intersected: VAUGHN ST, ABANDONED RR,  Facility Carried by Structure: SR 0309 NB AND SB
Minimum Vertical Clearance: 6.81m (22.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 23887,  Location: LUZERNE BORO OVER SR 1013 (Lat: 41.279856,  Lng: -75.894817),  Route carried "under" structure: State highway ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 5,046 (year 2022),  Truck Traffic: 4%,  Features Intersected: SR 1013 UNION STREET,  Facility Carried by Structure: SR 0309 TR 309
Minimum Vertical Clearance: 4.79m (15.72ft),  Kilometerpoint: 0.468,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 23887,  Location: LUZERNE BORO OVER SR 1013 (Lat: 41.279856,  Lng: -75.894817),  Route carried "under" structure: State highway ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 5,046 (year 2022),  Truck Traffic: 4%,  Features Intersected: SR 1013 UNION STREET,  Facility Carried by Structure: SR 0309 TR 309
Minimum Vertical Clearance: 4.79m (15.72ft),  Kilometerpoint: 0.468,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 23891,  Location: LUZERNE BORO OVER SR 8039 (Lat: 41.287556,  Lng: -75.904178),  Route carried "under" structure: Ramp State highway ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 3,815 (year 2022),  Truck Traffic: 7%,  Features Intersected: RAMP A; SR 8039,  Facility Carried by Structure: SR 0309 TR 309
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Discuss Luzerne, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.