Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Kingston, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 72ft / 22.3mTotal length
  • $803,000Total costs
  • 10,136Total average daily traffic
  • 321Total average daily truck traffic
  • 17,023Total future (year 2018) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Kingston
  • No street view available for this location

New bridges in Kingston, MI - historical statistics
  • New bridges - historical statistics
  • 31960-1969
  • 21970-1979
  • 51980-1989
  • 41990-1999
  • 22010-2019
Average Bridge Daily Traffic in Kingston, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 46.2%Good
  • 46.2%Satisfactory
  • 7.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 61.5%Good
  • 23.1%Satisfactory
  • 15.4%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 92.3%Good
  • 7.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.3%Very good
  • 31.3%Good
  • 56.3%Satisfactory
  • 6.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Very good
  • 33.3%Serious
Find on map >>   Show street view

Structure Number: 10425,  Location: 6.9 MI E OF M-24 (Lat: 43.411733,  Lng: -83.245764),  Route carried "on" structure: State highway 46,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 3,520 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,111 (year 2018),  Design Load: H 20,  Features Intersected: SUCKER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 36.678,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 27,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10459,  Location: SEC 13-24 WELLS TWP (Lat: 43.455439,  Lng: -83.232489),  Route carried "on" structure: County highway 7954,  Year Built: 1971,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,970 (year 2009),  Average Future Daily Traffic: 3,560 (year 2029),  Design Load: HS 20,  Features Intersected: BUTTERNUT CREEK DRAIN,  Facility Carried by Structure: BEVENS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.999,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.9m (22.6ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 79.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1046,  Location: SEC 16-21 KINGSTON TWP (Lat: 43.456214,  Lng: -83.182911),  Route carried "on" structure: County highway 7954,  Year Built: 1984,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 1,245 (year 2009),  Average Future Daily Traffic: 2,250 (year 2029),  Design Load: HS 20,  Features Intersected: CLARK DRAIN EXTENSION,  Facility Carried by Structure: BEVENS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.030,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10514,  Location: SEC 16-17 KINGSTON TWP (Lat: 43.460092,  Lng: -83.187456),  Route carried "on" structure: County highway 7987,  Year Built: 1986,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 1,390 (year 2009),  Average Future Daily Traffic: 2,510 (year 2029),  Design Load: HS 20,  Features Intersected: CLARK DRAIN EXTENSION,  Facility Carried by Structure: KINGSTON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.237,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.3m (66.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 92.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10565,  Location: SEC 11-14 DAYTON TWP (Lat: 43.382561,  Lng: -83.246150),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 2018,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 480 (year 2009),  Average Future Daily Traffic: 870 (year 2029),  Design Load: HL 93,  Features Intersected: SUCKER CREEK DRAIN,  Facility Carried by Structure: SHAYS LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.690,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 50.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.65m (5.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $479,000,  Roadway Improvement Cost: $189,000,  Total Project Cost: $803,000 ( Estimate for 2017),  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10567,  Location: SEC 1-12 DAYTON TWP (Lat: 43.397092,  Lng: -83.243028),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1983,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 50 (year 2009),  Average Future Daily Traffic: 90 (year 2029),  Design Load: HS 20,  Features Intersected: SUCKER CREEK DRAIN,  Facility Carried by Structure: HARMON LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.772,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 79.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10613,  Location: SEC 27-34 KINGSTON TWP (Lat: 43.427808,  Lng: -83.157839),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1983,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 110 (year 2009),  Average Future Daily Traffic: 200 (year 2029),  Design Load: HS 20,  Features Intersected: WHITE CREEK DRAIN #2,  Facility Carried by Structure: ROSSMAN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.135,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.3m (50.2ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10614,  Location: SEC 21-28 KINGSTON TWP (Lat: 43.441908,  Lng: -83.178522),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 2015,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 116 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 172 (year 2034),  Design Load: Greater than HL93,  Features Intersected: WHITE CREEK DRAIN #2,  Facility Carried by Structure: LEGG ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.300,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10615,  Location: SEC 17 KINGSTON TWP (Lat: 43.464569,  Lng: -83.195781),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1968,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 85 (year 2009),  Average Future Daily Traffic: 150 (year 2029),  Design Load: H 20,  Features Intersected: SOUTH BR WHITE CREEK,  Facility Carried by Structure: BOND ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.970,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10619,  Location: SEC 7 KINGSTON TWP (Lat: 43.474728,  Lng: -83.213119),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1968,  Status: Posted for load,  Structure Length: 1.53m (5.02ft),  Average Daily Traffic: 50 (year 2009),  Average Future Daily Traffic: 105 (year 2029),  Design Load: H 20,  Features Intersected: SOUTH BR WHITE CREEK,  Facility Carried by Structure: PHILLIPS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.507,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 36.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1062,  Location: SEC 17 KINGSTON TWP (Lat: 43.465089,  Lng: -83.197781),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1998,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 20 (year 2009),  Average Future Daily Traffic: 35 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SOUTH BR WHITE CREEK,  Facility Carried by Structure: ARTHUR ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.058,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.4m (47.2ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10621,  Location: SEC 27-28 KINGSTON TWP (Lat: 43.439422,  Lng: -83.166378),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.63m (5.35ft),  Average Daily Traffic: 105 (year 2009),  Average Future Daily Traffic: 190 (year 2029),  Design Load: HS 20,  Features Intersected: WHITE CREEK DRAIN #2,  Facility Carried by Structure: CEMETERY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.894,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10622,  Location: SEC 34-35 KINGSTON TWP (Lat: 43.424903,  Lng: -83.146308),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1987,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 90 (year 2009),  Average Future Daily Traffic: 160 (year 2029),  Design Load: HS 20,  Features Intersected: WHITE CREEK DRAIN #2,  Facility Carried by Structure: CLOTHIER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.252,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10626,  Location: SEC 15-22 KOYLTON TWP (Lat: 43.369908,  Lng: -83.155133),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1993,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 90 (year 2009),  Average Future Daily Traffic: 160 (year 2029),  Design Load: HS 20,  Features Intersected: MURDICK-VANSICKLAND DRN,  Facility Carried by Structure: CENTERLINE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.043,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.5m (34.4ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 35.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10627,  Location: SEC 14-15 KOYLTON TWP (Lat: 43.377294,  Lng: -83.145272),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1978,  Status: Posted for load,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 215 (year 2009),  Average Future Daily Traffic: 380 (year 2029),  Design Load: H 20,  Features Intersected: WHITE CREEK DRAIN #2,  Facility Carried by Structure: CLOTHIER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.641,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft)

Condition: Channel: Satisfactory,  Culverts: Serious,  Operating Rating: 6.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 3.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 10629,  Location: SEC 1-2 KOYLTON TWP (Lat: 43.409714,  Lng: -83.126208),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1993,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 600 (year 2009),  Average Future Daily Traffic: 1,080 (year 2029),  Design Load: HS 20,  Features Intersected: WHITE CREEK DRAIN #2,  Facility Carried by Structure: WHITE CREEK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.193,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Discuss Kingston, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.