Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Johnstown, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 33Number of bridges
  • 295ft / 90.0mTotal length
  • $206,000Total costs
  • 809,256Total average daily traffic
  • 94,890Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Johnstown
  • No street view available for this location

New bridges in Johnstown, CO - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11950-1959
  • 141960-1969
  • 21970-1979
  • 41980-1989
  • 41990-1999
  • 12000-2009
  • 32010-2019
  • 32020-2022
Average Bridge Daily Traffic in Johnstown, CO
Average Bridge Truck Traffic in Johnstown, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.7%Very good
  • 30.8%Good
  • 57.7%Satisfactory
  • 3.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 15.4%Very good
  • 23.1%Good
  • 46.2%Satisfactory
  • 15.4%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 3.8%Very good
  • 38.5%Good
  • 46.2%Satisfactory
  • 7.7%Fair
  • 3.8%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 31.6%Very good
  • 36.8%Good
  • 26.3%Satisfactory
  • 5.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 66.7%Satisfactory
Find on map >>   Show street view

Structure Number: C-17-AI,  Location: 4 MI NO OF JCT SH 66 (Lat: 40.262622,  Lng: -104.980694),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 652 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,930 (year 2028),  Design Load: HS 20,  Features Intersected: I 25 ML,  Facility Carried by Structure: COUNTY ROAD 38
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.525,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.0m (65.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: C-17-AJ,  Location: 4.9 MI E OF JCT US 287 (Lat: 40.306267,  Lng: -104.981419),  Route carried "on" structure: State highway 56B,  Year Built: 1961,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 7,000 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,710 (year 2040),  Design Load: H 20,  Features Intersected: I 25 ML,  Facility Carried by Structure: SH 56 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.618,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.0m (65.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: C-17-BA,  Location: IN JOHNSTOWN (Lat: 40.334686,  Lng: -104.911008),  Route carried "on" structure: State highway 60B,  Year Built: 1957,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 11,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,060 (year 2040),  Design Load: H 20,  Features Intersected: HILLSBORO DITCH,  Facility Carried by Structure: SH 60 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.955,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.2m (23.6ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: C-17-BB,  Location: AT JCT I 25 (Lat: 40.335556,  Lng: -104.980556),  Route carried "on" structure: State highway 60B,  Year Built: 1962,  Status: Closed,  Structure Length: 6.34m (20.80ft),  Average Daily Traffic: 12,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 18,720 (year 2040),  Design Load: HS 20,  Features Intersected: I 25 ML,  Facility Carried by Structure: SH 60 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.039,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: C-17-BQ,  Location: 0.9 MI NO OF JCT SH 60 EA (Lat: 40.349042,  Lng: -104.980844),  Route carried "on" structure: Interstate 25A,  Year Built: 1962,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 36,500 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 54,020 (year 2040),  Design Load: HS 20,  Features Intersected: SH 60 ML,  Facility Carried by Structure: I 25 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 407.095,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Membrane: Other
Find on map >>   Show street view

Structure Number: C-17-BR,  Location: 2.1 MI SO OF JCT SH 402 (Lat: 40.349039,  Lng: -104.981167),  Route carried "on" structure: Interstate 25A,  Year Built: 1962,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 36,500 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 54,020 (year 2040),  Design Load: HS 20,  Features Intersected: SH 60 ML,  Facility Carried by Structure: I 25 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 407.098,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 51.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Membrane: Other
Find on map >>   Show street view

Structure Number: C-17-CE,  Location: 1.5 MI NO OF JCT SH 56 WE (Lat: 40.328097,  Lng: -104.979958),  Route carried "on" structure: Interstate 25A,  Year Built: 1961,  Status: Open,  Structure Length: 2.48m (8.14ft),  Average Daily Traffic: 36,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 52,200 (year 2040),  Design Load: HL 93,  Features Intersected: GW RR,  Facility Carried by Structure: I 25 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 404.774,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: C-17-D,  Location: 2.9 MI E OF JCT I 25 (Lat: 40.406514,  Lng: -104.937258),  Route carried "on" structure: US 34A,  Year Built: 1934,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 1.72m (5.64ft),  Average Daily Traffic: 43,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 64,930 (year 2040),  Design Load: HS 20,  Features Intersected: LOVELAND-GREELEY CANAL,  Facility Carried by Structure: US 34 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 158.855,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 26 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.0m (26.2ft),  Out-to-Out Width: 54.3m (178.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: C-17-DH,  Location: 1 MI SO OF JCT SH 60 (Lat: 40.320772,  Lng: -104.980275),  Route carried "on" structure: Interstate 25A,  Year Built: 1962,  Status: Open,  Structure Length: 3.03m (9.94ft),  Average Daily Traffic: 36,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 52,200 (year 2040),  Design Load: HS 20,  Features Intersected: COUNTY ROAD 46,  Facility Carried by Structure: I 25 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 403.957,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Membrane: Other
Find on map >>   Show street view

Structure Number: C-17-DY,  Location: 1 MI NO OF JCT SH 56 (Lat: 40.320767,  Lng: -104.979950),  Route carried "on" structure: Interstate 25A,  Year Built: 1961,  Status: Open,  Structure Length: 3.03m (9.94ft),  Average Daily Traffic: 36,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 52,200 (year 2040),  Design Load: H 20,  Features Intersected: COUNTY ROAD 46,  Facility Carried by Structure: I 25 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 403.955,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Membrane: Other
Find on map >>   Show street view

Structure Number: C-17-EI,  Location: 1 MI N OF JCT SH 60 (Lat: 40.363519,  Lng: -104.985506),  Route carried "on" structure: Interstate 25A,  Year Built: 1962,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 36,500 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 54,020 (year 2040),  Design Load: HS 20,  Features Intersected: COUNTY ROAD 16,  Facility Carried by Structure: I 25 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 408.761,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 12 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Membrane: Other
Find on map >>   Show street view

Structure Number: C-17-ELA,  Location: 1.6 MI NO OF JCT SH 60 (Lat: 40.371589,  Lng: -104.990311),  Route carried "on" structure: Interstate 25A,  Year Built: 2020,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 86,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 93,620 (year 2031),  Design Load: HL 93,  Features Intersected: DRAW,  Facility Carried by Structure: I 25 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 409.751,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.7m (22.0ft),  Out-to-Out Width: 59.1m (193.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.64m (2.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $138,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $206,000
Find on map >>   Show street view

Structure Number: C-17-FF,  Location: 0.4 MI SO OF JCT SH 56 (Lat: 40.300833,  Lng: -104.980303),  Route carried "on" structure: Interstate 25A,  Year Built: 2020,  Status: Open,  Structure Length: 5.72m (18.77ft),  Average Daily Traffic: 84,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 50,560 (year 2031),  Design Load: HL 93,  Features Intersected: LITTLE THOMPSON RIVER,  Facility Carried by Structure: I 25 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 401.737,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 27.7m (90.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C-17-FS,  Location: 6.7 MI NO OF JCT SH 56 (Lat: 40.300794,  Lng: -104.979694),  Route carried "on" structure: ServiceInterstate 25A,  Year Built: 2013,  Status: Open,  Structure Length: 5.38m (17.65ft),  Average Daily Traffic: 72,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 106,560 (year 2040),  Design Load: HL 93,  Features Intersected: LITTLE THOMPSON RIVER SR,  Facility Carried by Structure: I 25 SERVICE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.760,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C-17-HG,  Location: 4.2 MI E OF JCT US 287 (Lat: 40.377697,  Lng: -104.993281),  Route carried "on" structure: State highway 402A,  Year Built: 2020,  Status: Open,  Structure Length: 6.87m (22.54ft),  Average Daily Traffic: 86,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 46,810 (year 2031),  Design Load: HL 93,  Features Intersected: I25 ML,  Facility Carried by Structure: SH 402 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.791,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.7m (110.6ft),  Curb or Sidewalk Widths: Left: 3.1m (10.2ft),  Right: 3.1m (10.2ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: JSTWN-001,  Location: 0.9 Mi N of Co Rd 44 (Lat: 40.318889,  Lng: -104.905944),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 2.35m (7.71ft),  Average Daily Traffic: 7,536 (year 2021),  Truck Traffic: 23%,  Average Future Daily Traffic: 10,701 (year 2041),  Design Load: HS 20,  Features Intersected: Little Thompson River,  Facility Carried by Structure: County Road 17
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.129,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.8m (71.5ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: JSTWN-002,  Location: 0.7 Mi N of Co Rd 44 (Lat: 40.315639,  Lng: -104.923528),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 2.76m (9.06ft),  Average Daily Traffic: 664 (year 2021),  Truck Traffic: 40%,  Average Future Daily Traffic: 943 (year 2041),  Design Load: HS 20,  Features Intersected: Little Thompson River,  Facility Carried by Structure: County Road 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.078,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.0m (85.3ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: JSTWN-003,  Location: 0.4 Mi E of Co Rd 17 (Lat: 40.327197,  Lng: -104.900022),  Route carried "on" structure: City street ,  Year Built: 1993,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 994 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 1,411 (year 2041),  Design Load: HS 20,  Features Intersected: Little Thompson River,  Facility Carried by Structure: County Road 46.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.220,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.5m (37.7ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: JSTWN-005,  Location: 0.1 Mi N of US Hwy 34 (Lat: 40.408528,  Lng: -104.944639),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.69m (5.54ft),  Average Daily Traffic: 11,391 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 14,239 (year 2041),  Design Load: HS 20,  Features Intersected: Greeley Loveland Canal,  Facility Carried by Structure: County Road 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.196,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: LR3-1.2-18,  Location: 1.2 Mi N of Co Rd 18 (Lat: 40.394278,  Lng: -104.964556),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 1,244 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 1,555 (year 2040),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.713,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: WEL013.0_048.0A,  Location: 0.95 Mi N of Co Rd 48 (Lat: 40.348944,  Lng: -104.943417),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 3,514 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,990 (year 2041),  Design Load: HS 20,  Features Intersected: Unnamed Creek,  Facility Carried by Structure: County Rd 13
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.498,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: WEL013.0_054.0A,  Location: 0.4 MI North of Co Rd 54 (Lat: 40.382583,  Lng: -104.945028),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 5,930 (year 2021),  Truck Traffic: 28%,  Average Future Daily Traffic: 8,421 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 13
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.700,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.8m (58.4ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 38.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: WEL017.0-050.0A,  Location: 0.9 Mi N of Co Rd 50 (Lat: 40.362500,  Lng: -104.907639),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 8,764 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 12,445 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 17
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.014,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: WEL019.0-046.5A,  Location: 0.1 Mi N of Co Rd 46.5 (Lat: 40.328972,  Lng: -104.886694),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 1.67m (5.48ft),  Average Daily Traffic: 3,087 (year 2021),  Truck Traffic: 36%,  Average Future Daily Traffic: 4,384 (year 2041),  Design Load: HS 20,  Features Intersected: Little Thompson River,  Facility Carried by Structure: County Road 19
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.610,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Fair,  Operating Rating: 54.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: WEL044.0-013.0B,  Location: 0.9 Mi E of Co Rd 13 (Lat: 40.305944,  Lng: -104.924833),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 962 (year 2021),  Truck Traffic: 46%,  Average Future Daily Traffic: 1,366 (year 2041),  Design Load: HS 20,  Features Intersected: Hillsbourough Ditch,  Facility Carried by Structure: County Road 44
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.035,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 23.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 14.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: WEL050.0-013.0A,  Location: 0.1 Mi E of Co Rd 13 (Lat: 40.349111,  Lng: -104.937222),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 0.92m (3.02ft),  Average Daily Traffic: 4,853 (year 2021),  Truck Traffic: 25%,  Average Future Daily Traffic: 6,891 (year 2041),  Design Load: HS 20,  Features Intersected: Local Drainage,  Facility Carried by Structure: County Road 50
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.497,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 79.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: WEL052.0_013.0A,  Location: 0.5 MI E OF CO RD 13 (Lat: 40.363528,  Lng: -104.935889),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 124 (year 2021),  Truck Traffic: 24%,  Average Future Daily Traffic: 176 (year 2041),  Design Load: HS 20,  Features Intersected: HILLSBOROUGH DITCH,  Facility Carried by Structure: CO RD 52
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.806,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.8m (35.4ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 56.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: WEL054.0-013.0A,  Location: 0.7 Mi E of Co Rd 13 (Lat: 40.378056,  Lng: -104.932500),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 4.70m (15.42ft),  Average Daily Traffic: 8,355 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 11,864 (year 2041),  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 54
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.078,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: WEL52.2-13A,  Location: 0.2 Mi E of Co Rd 13 (Lat: 40.367167,  Lng: -104.940083),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 0.86m (2.82ft),  Average Daily Traffic: 86 (year 2021),  Truck Traffic: 40%,  Average Future Daily Traffic: 122 (year 2041),  Design Load: HS 20,  Features Intersected: Hillsboro Ditch,  Facility Carried by Structure: Co Rd 52.25
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.444,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 76.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: C-17-AJ,  Location: 4.9 MI E OF JCT US 287 (Lat: 40.306267,  Lng: -104.981419),  Route carried "under" structure: Interstate 25A,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 64,000 (year 2011),  Truck Traffic: 14%,  Features Intersected: I 25 ML,  Facility Carried by Structure: SH 56 ML
Minimum Vertical Clearance: 5.87m (19.26ft),  Kilometerpoint: 402.638,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 20.0m (65.6ft)

Find on map >>   Show street view

Structure Number: C-17-BB,  Location: AT JCT I 25 (Lat: 40.335556,  Lng: -104.980556),  Route carried "under" structure: Interstate 25A,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 64,000 (year 2011),  Truck Traffic: 12%,  Features Intersected: I 25 ML,  Facility Carried by Structure: SH 60 ML
Minimum Vertical Clearance: 5.62m (18.44ft),  Kilometerpoint: 405.888,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: C-17-BQ,  Location: 0.9 MI NO OF JCT SH 60 EA (Lat: 40.349042,  Lng: -104.980844),  Route carried "under" structure: State highway 60A,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 2,300 (year 2011),  Truck Traffic: 6%,  Features Intersected: SH 60 ML,  Facility Carried by Structure: I 25 ML NBND
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 7.977,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 13.1m (43.0ft)

Find on map >>   Show street view

Structure Number: C-17-BR,  Location: 2.1 MI SO OF JCT SH 402 (Lat: 40.349039,  Lng: -104.981167),  Route carried "under" structure: State highway 60A,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 2,300 (year 2011),  Truck Traffic: 6%,  Features Intersected: SH 60 ML,  Facility Carried by Structure: I 25 ML SBND
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 7.976,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 13.1m (43.0ft)