Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Jesup, Iowa (IA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 41Number of bridges
  • 338ft / 103mTotal length
  • 76,255Total average daily traffic
  • 13,718Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Jesup
  • No street view available for this location

New bridges in Jesup, IA - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 41950-1959
  • 31960-1969
  • 131980-1989
  • 51990-1999
  • 102000-2009
  • 42010-2019
Average Bridge Daily Traffic in Jesup, IA
Average Bridge Truck Traffic in Jesup, IA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 23.1%Very good
  • 50.0%Good
  • 7.7%Satisfactory
  • 19.2%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 26.9%Very good
  • 46.2%Good
  • 7.7%Satisfactory
  • 15.4%Fair
  • 3.8%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 34.6%Very good
  • 38.5%Good
  • 11.5%Satisfactory
  • 7.7%Fair
  • 3.8%Poor
  • 3.8%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 30.3%Very good
  • 45.5%Good
  • 15.2%Satisfactory
  • 9.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 54.5%Good
  • 45.5%Satisfactory
Find on map >>   Show street view

Structure Number: 1468,  Location: 88-11-04-03-10 (Lat: 42.468322,  Lng: -92.130450),  Route carried "on" structure: County highway ,  Year Built: 1957,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 2,530 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,530 (year 2041),  Design Load: H 20,  Features Intersected: INDIAN CREEK,  Facility Carried by Structure: DUBUQUE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.845,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 24.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 3.90m (12.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $75,000,  Roadway Improvement Cost: $45,000
Find on map >>   Show street view

Structure Number: 1469,  Location: 88-11-02-01-10 (Lat: 42.468192,  Lng: -92.089297),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 2,530 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,530 (year 2041),  Design Load: H 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: DUBUQUE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.227,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.00m (13.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $1,000
Find on map >>   Show street view

Structure Number: 15811,  Location: 088100615 (Lat: 42.468144,  Lng: -92.050747),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 2,540 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 2,540 (year 2040),  Design Load: HS 20,  Features Intersected: SMALL NATURAL STREAM,  Facility Carried by Structure: 220TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.153,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 43.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 74811,  Location: 88-11-09-01-10 (Lat: 42.456861,  Lng: -92.140139),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 60 (year 2017),  Average Future Daily Traffic: 60 (year 2039),  Design Load: HS 20,  Features Intersected: INDIAN CREEK,  Facility Carried by Structure: YOUNG RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.591,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 66.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 42.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 74841,  Location: 88-11-12-01-10 (Lat: 42.456822,  Lng: -92.080111),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 400 (year 2021),  Truck Traffic: 20%,  Average Future Daily Traffic: 400 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: YOUNG RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.568,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 75.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 74851,  Location: 88-11-12-10-10 (Lat: 42.443644,  Lng: -92.074092),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 200 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2041),  Design Load: H 20,  Features Intersected: TRIB TO SPRING CREEK,  Facility Carried by Structure: SPRING CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.009,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 74861,  Location: 88-11-13-01-10 (Lat: 42.442372,  Lng: -92.079492),  Route carried "on" structure: County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 60 (year 2017),  Average Future Daily Traffic: 60 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: INDIAN CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.350,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 66.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 74871,  Location: 88-11-14-02-10 (Lat: 42.430314,  Lng: -92.103272),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Posted for load,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 400 (year 2021),  Truck Traffic: 20%,  Average Future Daily Traffic: 400 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB TO SPRING CREEK,  Facility Carried by Structure: JESUP RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.944,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 74881,  Location: 88-11-15-01-10 (Lat: 42.442242,  Lng: -92.114033),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 50 (year 2039),  Design Load: HS 20,  Features Intersected: TRIB TO SPRING CREEK,  Facility Carried by Structure: INDIAN CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.510,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 74961,  Location: 88-11-23-01-10 (Lat: 42.427989,  Lng: -92.099203),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 50 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: TRIB TO SPRING CREEK,  Facility Carried by Structure: FOX RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.685,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 47.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 7497,  Location: 88-11-23-02-10 (Lat: 42.421983,  Lng: -92.103333),  Route carried "on" structure: County highway ,  Year Built: 1924,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 400 (year 2021),  Truck Traffic: 20%,  Average Future Daily Traffic: 400 (year 2041),  Design Load: HS 15,  Features Intersected: TRIB TO SPRING CREEK,  Facility Carried by Structure: JESUP RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.019,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 7498,  Location: 88-11-24-01 (Lat: 42.427964,  Lng: -92.079128),  Route carried "on" structure: County highway ,  Year Built: 1949,  Status: Posted for load,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 50 (year 2041),  Features Intersected: SPRING CREEK,  Facility Carried by Structure: FOX RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.336,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Serious,  Channel: Good,  Operating Rating: 36.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Critical Feature Inspection Date: September 2020,  Bridge Improvement Cost: $280,000,  Roadway Improvement Cost: $20,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 74991,  Location: 88-11-25-01-10 (Lat: 42.413519,  Lng: -92.081528),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 35 (year 2017),  Average Future Daily Traffic: 35 (year 2041),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: POYNER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.446,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 88.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 75521,  Location: 89-11-13-04-10 (Lat: 42.519744,  Lng: -92.096794),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 10 (year 2021),  Average Future Daily Traffic: 10 (year 2038),  Features Intersected: CAMP CREEK,  Facility Carried by Structure: BAKER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.888,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 75531,  Location: 89-11-13-05-10 (Lat: 42.522747,  Lng: -92.093289),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 90 (year 2021),  Average Future Daily Traffic: 90 (year 2038),  Design Load: HS 20,  Features Intersected: CAMP CREEK,  Facility Carried by Structure: BARCLAY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.191,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 75.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 75541,  Location: 89-11-13-06-10 (Lat: 42.523725,  Lng: -92.092008),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 45 (year 2017),  Average Future Daily Traffic: 45 (year 2038),  Design Load: HS 20,  Features Intersected: CAMP CREEK,  Facility Carried by Structure: CUNNINGHAM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.106,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 80.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 75581,  Location: 89-11-23-01-10 (Lat: 42.511767,  Lng: -92.106983),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 45 (year 2017),  Average Future Daily Traffic: 45 (year 2040),  Design Load: HS 20,  Features Intersected: CAMP CREEK,  Facility Carried by Structure: NEWELL ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.774,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 75651,  Location: 89-11-36-01-10 (Lat: 42.482747,  Lng: -92.083511),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 660 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 660 (year 2040),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: OSAGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.205,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 82271,  Location: 088100608 (Lat: 42.459425,  Lng: -92.055728),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 2,970 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 2,970 (year 2040),  Design Load: HL 93,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: V65
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.541,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Galvanized Reinforcing
Find on map >>   Show street view

Structure Number: 8231,  Location: 088102102 (Lat: 42.420097,  Lng: -92.025864),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Posted for load,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 10 (year 2013),  Average Future Daily Traffic: 10 (year 2041),  Features Intersected: SPRING CR,  Facility Carried by Structure: DANIAL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.263,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 30.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 8.80m (28.87ft),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Bridge Improvement Cost: $140,000,  Roadway Improvement Cost: $30,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 83061,  Location: 089100703 (Lat: 42.533411,  Lng: -92.066422),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 35 (year 2017),  Average Future Daily Traffic: 35 (year 2042),  Features Intersected: SMALL STREAM,  Facility Carried by Structure: 175TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.287,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 83071,  Location: 089100703 (Lat: 42.533628,  Lng: -92.080864),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 35 (year 2017),  Average Future Daily Traffic: 35 (year 2042),  Design Load: HS 20,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: LOCAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.101,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 75.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 83081,  Location: 089100802 (Lat: 42.536050,  Lng: -92.062692),  Route carried "on" structure: County highway ,  Year Built: 2018,  Status: Open,  Structure Length: 2.23m (7.32ft),  Average Daily Traffic: 1,390 (year 2021),  Truck Traffic: 17%,  Average Future Daily Traffic: 1,390 (year 2040),  Design Load: HL 93,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: V62 BAXTER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.926,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 6.2m (20.3ft),  Right: 6.2m (20.3ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8309,  Location: 089100802 (Lat: 42.540194,  Lng: -92.062594),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 10.70m (35.10ft),  Average Daily Traffic: 1,390 (year 2021),  Truck Traffic: 17%,  Average Future Daily Traffic: 1,390 (year 2041),  Design Load: H 20,  Features Intersected: WAPSIPINICON RIVER,  Facility Carried by Structure: FM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.386,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.9m (98.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Channel: Fair,  Operating Rating: 29.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 38.60m (126.64ft),  Designated Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: March 2021,  Other Special Inspection Date: November 2021,  Bridge Improvement Cost: $656,000,  Roadway Improvement Cost: $15,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 831,  Location: 089100907 (Lat: 42.533297,  Lng: -92.030683),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 7.74m (25.39ft),  Average Daily Traffic: 570 (year 2021),  Truck Traffic: 21%,  Average Future Daily Traffic: 570 (year 2042),  Design Load: H 20,  Features Intersected: WAPSIPINICON RIVER,  Facility Carried by Structure: FM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.223,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 39.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 27.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 27.90m (91.54ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $474,000,  Roadway Improvement Cost: $15,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8311,  Location: 089100909 (Lat: 42.533317,  Lng: -92.028758),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 570 (year 2021),  Truck Traffic: 21%,  Average Future Daily Traffic: 570 (year 2042),  Design Load: H 20,  Features Intersected: OVFLOW WAPSIPINICON RIVE,  Facility Carried by Structure: FM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.381,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.30m (43.64ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $226,000,  Roadway Improvement Cost: $30,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 83131,  Location: 089101011 (Lat: 42.529394,  Lng: -92.016983),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 70 (year 2013),  Average Future Daily Traffic: 70 (year 2042),  Design Load: HS 20,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: LOCAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.526,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 83211,  Location: 08910275000 (Lat: 42.497233,  Lng: -92.013606),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 15 (year 2021),  Average Future Daily Traffic: 15 (year 2042),  Design Load: HS 20,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: LOCAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.787,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 83221,  Location: 089102701 (Lat: 42.497231,  Lng: -92.012886),  Route carried "on" structure: County highway ,  Year Built: 2015,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 15 (year 2021),  Average Future Daily Traffic: 15 (year 2042),  Design Load: HS 20,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: 200TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.847,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 8323,  Location: 089102802 (Lat: 42.487925,  Lng: -92.042225),  Route carried "on" structure: County highway ,  Year Built: 1951,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 150 (year 2021),  Average Future Daily Traffic: 150 (year 2042),  Design Load: H 20,  Features Intersected: STREAM,  Facility Carried by Structure: FM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.778,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.50m (8.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $43,000,  Roadway Improvement Cost: $15,000
Find on map >>   Show street view

Structure Number: 83241,  Location: 089103304 (Lat: 42.469581,  Lng: -92.041672),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 130 (year 2013),  Truck Traffic: 18%,  Average Future Daily Traffic: 130 (year 2040),  Design Load: HS 20,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: CARTER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.718,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.40m (17.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Bridge Improvement Cost: $92,000,  Roadway Improvement Cost: $30,000
Find on map >>   Show street view

Structure Number: 604895,  Location: 0.4 mi. W of jct. SR V65 (Lat: 42.449031,  Lng: -92.064164),  Route carried "on" structure: US 20,  Year Built: 1980,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 9,900 (year 2020),  Truck Traffic: 19%,  Average Future Daily Traffic: 9,900 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 362.653,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 6049,  Location: At Jct. US 20 & SR V65 (Lat: 42.448764,  Lng: -92.055569),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 8.17m (26.80ft),  Design Load: HS 20,  Features Intersected: US 20,  Facility Carried by Structure: FM V-65
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.357,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 604905,  Location: 6.0 MI. W OF JCT. 150 (Lat: 42.449842,  Lng: -92.006903),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 8.17m (26.80ft),  Average Daily Traffic: 450 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 450 (year 2041),  Design Load: H 20,  Features Intersected: US 20,  Facility Carried by Structure: V71
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.579,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 604965,  Location: 2.4 MI. W OF SR V65. (Lat: 42.449106,  Lng: -92.103089),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 8.17m (26.80ft),  Average Daily Traffic: 400 (year 2021),  Truck Traffic: 20%,  Average Future Daily Traffic: 400 (year 2041),  Design Load: H 20,  Features Intersected: US 20,  Facility Carried by Structure: FM CO V062
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.030,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 60497,  Location: 1.3 mi. W of jct. SR V65 (Lat: 42.449136,  Lng: -92.080800),  Route carried "on" structure: US 20,  Year Built: 1980,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 9,900 (year 2020),  Truck Traffic: 19%,  Average Future Daily Traffic: 9,900 (year 2042),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 361.285,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 604975,  Location: 0.9 mi. W of Jct. SR V65 (Lat: 42.448847,  Lng: -92.073783),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 8.14m (26.71ft),  Average Daily Traffic: 200 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2041),  Design Load: H 20,  Features Intersected: US 20,  Facility Carried by Structure: SPRING CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.587,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6049,  Location: At Jct. US 20 & SR V65 (Lat: 42.448764,  Lng: -92.055569),  Route carried "under" structure: US 20,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 8,700 (year 2020),  Truck Traffic: 20%,  Features Intersected: US 20,  Facility Carried by Structure: FM V-65
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 363.358,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 604905,  Location: 6.0 MI. W OF JCT. 150 (Lat: 42.449842,  Lng: -92.006903),  Route carried "under" structure: US 20,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 9,400 (year 2020),  Truck Traffic: 20%,  Features Intersected: US 20,  Facility Carried by Structure: V71
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 367.360,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 604965,  Location: 2.4 MI. W OF SR V65. (Lat: 42.449106,  Lng: -92.103089),  Route carried "under" structure: US 20,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 9,900 (year 2020),  Truck Traffic: 19%,  Features Intersected: US 20,  Facility Carried by Structure: FM CO V062
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 359.452,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 604975,  Location: 0.9 mi. W of Jct. SR V65 (Lat: 42.448847,  Lng: -92.073783),  Route carried "under" structure: US 20,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 9,900 (year 2020),  Truck Traffic: 19%,  Features Intersected: US 20,  Facility Carried by Structure: SPRING CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 361.855,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Discuss Jesup, Iowa (IA) on our hugely popular Iowa forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.