Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Holiday Valley, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 180ft / 55.2mTotal length
  • 219,257Total average daily traffic
  • 40,894Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Holiday Valley
  • No street view available for this location

New bridges in Holiday Valley, OH - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11930-1939
  • 11950-1959
  • 11960-1969
  • 51970-1979
  • 11990-1999
Reconstructed bridges in Holiday Valley, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 21990-1999
  • 02000-2009
  • 22010-2019
Average Bridge Daily Traffic in Holiday Valley, OH
Average Bridge Truck Traffic in Holiday Valley, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 62.5%Good
  • 12.5%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 37.5%Very good
  • 50.0%Good
  • 12.5%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.0%Very good
  • 62.5%Good
  • 12.5%Satisfactory
Find on map >>   Show street view

Structure Number: 1206567,  Location: JCT. IR-675 AND IR-70 (Lat: 39.864981,  Lng: -83.994011),  Route carried "on" structure: Interstate 675,  Year Built: 1975,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 9.42m (30.91ft),  Average Daily Traffic: 20,000 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 23,000 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: IR 70
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.010,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1206575,  Location: JCT. IR-675 AND IR-70 (Lat: 39.865061,  Lng: -83.993569),  Route carried "on" structure: Interstate 675,  Year Built: 1975,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 9.51m (31.20ft),  Average Daily Traffic: 20,000 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 23,000 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: IR 70
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 90.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1252003,  Location: 1/2MI EAST ST RT 675 (Lat: 39.847911,  Lng: -83.986239),  Route carried "on" structure: County highway C0333,  Year Built: 1952,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 10,558 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,655 (year 2035),  Design Load: H 15,  Features Intersected: DAYTON RD & MUD RUN,  Facility Carried by Structure: C-333
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 125207,  Location: .75 MI. E. I-675 (Lat: 39.849169,  Lng: -83.983161),  Route carried "on" structure: County highway C0333,  Year Built: 1939,  Year Reconstructed: 1990,  Status: Posted for load,  Structure Length: 23.38m (76.71ft),  Average Daily Traffic: 10,558 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,655 (year 2035),  Design Load: H 15,  Features Intersected: DAYTON RD O CONRAIL RR,  Facility Carried by Structure: C-333
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.547,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Critical Feature Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1252305,  Location: 1/2MI SO UNION RD (Lat: 39.870039,  Lng: -83.993431),  Route carried "on" structure: County highway C0335,  Year Built: 1975,  Status: Open,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 9,442 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 13,105 (year 2035),  Features Intersected: SPANGLER RD & BR SMITH D,  Facility Carried by Structure: C-335
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1252453,  Location: 1/2 MILE N DAYTON SP RD. (Lat: 39.865731,  Lng: -83.966411),  Route carried "on" structure: County highway T0151,  Year Built: 1929,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 910 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,263 (year 2035),  Design Load: HS 20,  Features Intersected: SNIDER RD OV SMITH DITCH,  Facility Carried by Structure: T 151
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.483,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1253751,  Location: .5 MI.SO.DAYTON SPLFD.RD. (Lat: 39.857581,  Lng: -83.965061),  Route carried "on" structure: County highway T0001,  Year Built: 1998,  Status: Open,  Structure Length: 3.02m (9.91ft),  Average Daily Traffic: 261 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 362 (year 2035),  Design Load: HS 20,  Features Intersected: HAHN AVE OV. MUD RUN,  Facility Carried by Structure: HAHN AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.150,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 1253808,  Location: 1/2MI SO DAYTON SPLFD RD (Lat: 39.854689,  Lng: -83.967081),  Route carried "on" structure: County highway T1479,  Year Built: 1968,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 1,949 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,705 (year 2035),  Design Load: H 20,  Features Intersected: WESTCOTT AVE O MUD RUN,  Facility Carried by Structure: T-1479
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.515,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1206567,  Location: JCT. IR-675 AND IR-70 (Lat: 39.864981,  Lng: -83.994011),  Route carried "under" structure: Interstate 70,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 64,894 (year 2016),  Truck Traffic: 26%,  Features Intersected: IR-675,  Facility Carried by Structure: IR-675
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 4.989,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 1206575,  Location: JCT. IR-675 AND IR-70 (Lat: 39.865061,  Lng: -83.993569),  Route carried "under" structure: Interstate 70,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 80,685 (year 2016),  Truck Traffic: 23%,  Features Intersected: IR-675,  Facility Carried by Structure: IR-675
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 5.021,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Discuss Holiday Valley, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.