Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Herscher, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 26Number of bridges
  • 164ft / 50.2mTotal length
  • 11,300Total average daily traffic
  • 1,101Total average daily truck traffic
  • 15,472Total future (year 2032) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Herscher
  • No street view available for this location

New bridges in Herscher, IL - historical statistics
  • New bridges - historical statistics
  • 21960-1969
  • 61970-1979
  • 91980-1989
  • 41990-1999
  • 42000-2009
  • 12010-2019
Average Bridge Truck Traffic in Herscher, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.2%Very good
  • 83.3%Good
  • 8.3%Fair
  • 4.2%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 8.3%Very good
  • 79.2%Good
  • 4.2%Satisfactory
  • 4.2%Fair
  • 4.2%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.5%Very good
  • 41.7%Good
  • 20.8%Satisfactory
  • 20.8%Fair
  • 4.2%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.7%Very good
  • 11.5%Good
  • 57.7%Satisfactory
  • 23.1%Fair
Find on map >>   Show street view

Structure Number: 384809,  Location: 1.7 MI W CH8 ON CH37 (Lat: 40.997994,  Lng: -88.126111),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 450 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 417 (year 2032),  Design Load: HS 20,  Features Intersected: W BR. OF HORSE CRK,  Facility Carried by Structure: FAS 1322 (CH 37)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.499,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 460109,  Location: .5 MI W OF HERSCHER (Lat: 41.056369,  Lng: -88.125961),  Route carried "on" structure: State highway 115,  Year Built: 1982,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 2.76m (9.06ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 1,784 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: W BR OF HORSE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 74.816,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.9m (29.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 460133,  Location: 15.1 MI W OF US 45 (Lat: 41.057147,  Lng: -88.092575),  Route carried "on" structure: State highway 115,  Year Built: 2004,  Status: Open,  Structure Length: 3.00m (9.84ft),  Average Daily Traffic: 1,400 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 2,594 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 77.633,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 65.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 462013,  Location: 2 MI E BUCKINGHAM RD (Lat: 41.056019,  Lng: -88.137947),  Route carried "on" structure: State highway 115,  Year Built: 2003,  Status: Open,  Structure Length: 0.86m (2.82ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 1,784 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 73.802,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 46303,  Location: 3 MI EAST OF CABERY (Lat: 40.997344,  Lng: -88.142975),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 450 (year 2019),  Truck Traffic: 29%,  Average Future Daily Traffic: 426 (year 2032),  Design Load: HS 15,  Features Intersected: W.BR. HORSE CR.,  Facility Carried by Structure: CH-37
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.787,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 463044,  Location: 2.8 MI E HERSCHER (Lat: 41.050319,  Lng: -88.037150),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 75 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 108 (year 2032),  Design Load: HS 15,  Features Intersected: HORSE CR,  Facility Carried by Structure: TR 60
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.483,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 463302,  Location: 0.5 MI E HERSCHER (Lat: 41.042717,  Lng: -88.084592),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 225 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 270 (year 2032),  Design Load: HS 15,  Features Intersected: E BR HORSECREEK,  Facility Carried by Structure: TR 165A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463315,  Location: 1.25 MI W HERSCHER (Lat: 41.037386,  Lng: -88.132947),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 54 (year 2032),  Design Load: HS 15,  Features Intersected: W BR OF HORSE CR,  Facility Carried by Structure: TR 32
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.851,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463317,  Location: 1.5 MI SE OF HERSCHE (Lat: 41.028114,  Lng: -88.083453),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 54 (year 2032),  Design Load: HS 15,  Features Intersected: HORSE CR E. BR.,  Facility Carried by Structure: TR 173
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.904,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463327,  Location: 0.6 MI W HERSCHER (Lat: 41.041717,  Lng: -88.126342),  Route carried "on" structure: County highway ,  Year Built: 1976,  Status: Open,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 175 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 297 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: W BRANCH HORSE CREEK,  Facility Carried by Structure: TR 165
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.300,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463345,  Location: 2 M E OF HERSCHER (Lat: 41.047111,  Lng: -88.056319),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 81 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: TR 54
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.805,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Fair,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463351,  Location: 3 MI N HERSCHER (Lat: 41.099972,  Lng: -88.096244),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 1,850 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 1,946 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CR,  Facility Carried by Structure: CH 12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.899,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 463364,  Location: 3 MI N HERSCHER (Lat: 41.101156,  Lng: -88.095508),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 75 (year 2020),  Average Future Daily Traffic: 81 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CR,  Facility Carried by Structure: TR 119
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.752,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 46338,  Location: 1.5 MI NW HERSCHER (Lat: 41.071092,  Lng: -88.125425),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 54 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CREEK W BR,  Facility Carried by Structure: TR 147
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.460,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463381,  Location: 1 MI N HERSCHER (Lat: 41.071575,  Lng: -88.105622),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 54 (year 2032),  Design Load: HS 20,  Features Intersected: E BR HORSE CR,  Facility Carried by Structure: TR 147
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.134,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463406,  Location: 4 MI SW HERSCHER (Lat: 41.011997,  Lng: -88.138031),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 75 (year 2020),  Average Future Daily Traffic: 81 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CR WBR,  Facility Carried by Structure: TR 177
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.253,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463409,  Location: 2.5 MI NO.HERSCHER (Lat: 41.086283,  Lng: -88.104647),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 50 (year 2012),  Truck Traffic: 16%,  Average Future Daily Traffic: 108 (year 2032),  Design Load: HS 20,  Features Intersected: SO. BR.HORSE CREEK,  Facility Carried by Structure: TR 125
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.343,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463424,  Location: 2.25 MI N HERSCHER (Lat: 41.086428,  Lng: -88.100833),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 50 (year 2012),  Truck Traffic: 16%,  Average Future Daily Traffic: 108 (year 2032),  Design Load: HS 20,  Features Intersected: E BR HORSE CREEK,  Facility Carried by Structure: TR 125
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.665,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.3m (40.4ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463425,  Location: 2.5 MI SW HERSCHER (Lat: 41.026667,  Lng: -88.141469),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 54 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CREEK,  Facility Carried by Structure: TR 173
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.012,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463427,  Location: 1 MI. EASTHERSCHER (Lat: 41.049803,  Lng: -88.075661),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 75 (year 2021),  Average Future Daily Traffic: 81 (year 2032),  Design Load: HS 20,  Features Intersected: E.BR.HORSECREEK,  Facility Carried by Structure: TR 50
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.483,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463452,  Location: 1.5 MI N HERSCHER (Lat: 41.079344,  Lng: -88.086086),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 25 (year 2020),  Average Future Daily Traffic: 27 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CREEK,  Facility Carried by Structure: TR 135
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.1m (36.4ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463453,  Location: 3.5 MI S OF HERSHER (Lat: 41.006617,  Lng: -88.114000),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 25 (year 2021),  Average Future Daily Traffic: 27 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB. OF HORSE CREEK,  Facility Carried by Structure: TR36A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.301,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463474,  Location: .2 MI N HERSCHER (Lat: 41.060161,  Lng: -88.095147),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 4.22m (13.85ft),  Average Daily Traffic: 2,000 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,378 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CREEK,  Facility Carried by Structure: CH 12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.308,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 463475,  Location: 1.7 MI N OF HERSCHER (Lat: 41.080814,  Lng: -88.095722),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 2.57m (8.43ft),  Average Daily Traffic: 1,600 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 2,378 (year 2032),  Design Load: HS 20,  Features Intersected: HORSE CREEK,  Facility Carried by Structure: FAS 319/CH 12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.023,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.1m (82.3ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 463484,  Location: .75 MI N IL 115 (Lat: 41.065953,  Lng: -88.133600),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 2.34m (7.68ft),  Average Daily Traffic: 150 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 162 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB W BRANCH HORSE,  Facility Carried by Structure: TR 32
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.681,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 463499,  Location: 13700 W 7000 S (Lat: 41.012567,  Lng: -88.127525),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 1.51m (4.95ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 64 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: TRIB HORSE CREEK,  Facility Carried by Structure: TR 177 B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.7m (48.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels
Discuss Herscher, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.