Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Hennepin, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 449ft / 137mTotal length
  • 23,000Total average daily traffic
  • 7,062Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Hennepin
  • No street view available for this location

New bridges in Hennepin, IL - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11950-1959
  • 71960-1969
  • 11970-1979
  • 21990-1999
  • 22000-2009
  • 12010-2019
Average Bridge Daily Traffic in Hennepin, IL
Average Bridge Truck Traffic in Hennepin, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 8.3%Excellent
  • 8.3%Very good
  • 16.7%Good
  • 33.3%Satisfactory
  • 8.3%Fair
  • 8.3%Poor
  • 8.3%Serious
  • 8.3%Critical
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 8.3%Very good
  • 50.0%Good
  • 8.3%Satisfactory
  • 8.3%Fair
  • 8.3%Poor
  • 8.3%Serious
  • 8.3%Critical
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.0%Very good
  • 16.7%Good
  • 33.3%Satisfactory
  • 16.7%Fair
  • 8.3%Critical
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 18.2%Very good
  • 18.2%Good
  • 45.5%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
Find on map >>   Show street view

Structure Number: 780001,  Location: 1.82 MI E OF ILL 26 (Lat: 41.262183,  Lng: -89.353650),  Route carried "on" structure: Interstate 180,  Year Built: 1969,  Status: Open,  Structure Length: 93.98m (308.33ft),  Average Daily Traffic: 2,250 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 2,896 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ILLINOIS RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.263,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 30 degrees,  Navigation Control: Yes ( Vertical Clearance: 12.8m (42.0ft), Horizontal Clearance: 106.7m (350.1ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 12,  Length of Maximum Span: 114.3m (375.0ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Excellent,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Underwater Inspection Date: August 2021,  Other Special Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 78001,  Location: JCT I 180 AND ILL 26 (Lat: 41.256781,  Lng: -89.328119),  Route carried "on" structure: Other road ,  Year Built: 1969,  Status: Open,  Structure Length: 8.35m (27.40ft),  Average Future Daily Traffic: 1,128 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: I-180/IL 71,  Facility Carried by Structure: IL 26 & OR 26
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.113,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.2m (99.1ft),  Curb-To-Curb Width: 21.5m (70.5ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 780018,  Location: 4.75 MI S OF ILL 71 (Lat: 41.189703,  Lng: -89.308831),  Route carried "on" structure: State highway 26,  Year Built: 1956,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 1,050 (year 2021),  Truck Traffic: 30%,  Average Future Daily Traffic: 820 (year 2032),  Design Load: HS 15,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.820,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Fair,  Channel: Poor,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 780022,  Location: 0.17 MI N OF ILL 26 (Lat: 41.258981,  Lng: -89.339831),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 7.67m (25.16ft),  Average Daily Traffic: 300 (year 2018),  Truck Traffic: 24%,  Average Future Daily Traffic: 769 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: FAI-180,  Facility Carried by Structure: CH 1
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 3.717,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 780032,  Location: 5.14 MI W OF ILL 89 (Lat: 41.256758,  Lng: -89.300497),  Route carried "on" structure: State highway 71,  Year Built: 1977,  Year Reconstructed: 2021,  Status: Open,  Structure Length: 2.24m (7.35ft),  Average Daily Traffic: 3,700 (year 2021),  Truck Traffic: 28%,  Average Future Daily Traffic: 3,700 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: COFFEE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.301,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Critical,  Superstructure: Critical,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of replacement,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 780035,  Location: 0.6mi E of IL 26 (Lat: 41.256831,  Lng: -89.315589),  Route carried "on" structure: State highway 71,  Year Built: 1993,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 3,400 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 3,229 (year 2032),  Design Load: HS 20,  Features Intersected: COFFEE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.014,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 75.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 780037,  Location: 3.76 MI S OF IL 71 (Lat: 41.203994,  Lng: -89.308844),  Route carried "on" structure: State highway 26,  Year Built: 2001,  Status: Open,  Structure Length: 3.25m (10.66ft),  Average Daily Traffic: 1,050 (year 2021),  Truck Traffic: 30%,  Average Future Daily Traffic: 820 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO ILL RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.413,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 780046,  Location: 1.21 MI S OF IL 71 (Lat: 41.239892,  Lng: -89.330069),  Route carried "on" structure: State highway 26,  Year Built: 2009,  Status: Open,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 1,200 (year 2021),  Truck Traffic: 25%,  Average Future Daily Traffic: 1,025 (year 2032),  Design Load: HS 20,  Features Intersected: COFFEE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 64.903,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 70.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 782002,  Location: 0.1 MI E OF ILL 26S (Lat: 41.256708,  Lng: -89.322456),  Route carried "on" structure: State highway 71,  Year Built: 1968,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 3,400 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 3,229 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 12 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: 783009,  Location: 1055N, 875E (Lat: 41.257761,  Lng: -89.304200),  Route carried "on" structure: County highway ,  Year Built: 1966,  Status: Posted for load,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 150 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 666 (year 2032),  Design Load: HS 15,  Features Intersected: COFFEE CREEK,  Facility Carried by Structure: TR 36
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.189,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Critical,  Channel: Fair,  Operating Rating: 20.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 2.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of replacement,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: March 2020,  Other Special Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 78302,  Location: 970N, 780E (Lat: 41.247897,  Lng: -89.322725),  Route carried "on" structure: County highway ,  Year Built: 1939,  Year Reconstructed: 2000,  Status: Posted for load,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 175 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 179 (year 2032),  Design Load: HS 20,  Features Intersected: COFFEE CR,  Facility Carried by Structure: CH 10
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.642,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 84.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 783111,  Location: 1250N, 950E (Lat: 41.286761,  Lng: -89.290608),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 4.06m (13.32ft),  Average Daily Traffic: 125 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 256 (year 2032),  Design Load: HS 20,  Features Intersected: ALLFORKS CREEK,  Facility Carried by Structure: TR 7
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.430,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.0m (78.7ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 783115,  Location: NE1/4-11-T32NR2W (Lat: 41.258556,  Lng: -89.311286),  Route carried "on" structure: County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 1,700 (year 2021),  Truck Traffic: 74%,  Average Future Daily Traffic: 766 (year 2032),  Design Load: HS 20,  Features Intersected: COFFEE CREEK,  Facility Carried by Structure: TR 36A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.055,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 78001,  Location: JCT I 180 AND ILL 26 (Lat: 41.256786,  Lng: -89.328317),  Route carried "under" structure: Interstate 180,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 2,250 (year 2021),  Truck Traffic: 35%,  Features Intersected: I-180/IL 71,  Facility Carried by Structure: IL 26 & OR 26
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 21.211,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.2m (99.1ft)

Find on map >>   Show street view

Structure Number: 780022,  Location: 0.17 MI N OF ILL 26 (Lat: 41.258981,  Lng: -89.339831),  Route carried "under" structure: Interstate 180,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 2,250 (year 2021),  Truck Traffic: 35%,  Features Intersected: FAI-180,  Facility Carried by Structure: CH 1
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 20.197,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Discuss Hennepin, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.