Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Gobles, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 25Number of bridges
  • 187ft / 57.4mTotal length
  • $575,000Total costs
  • 60,154Total average daily traffic
  • 4,149Total average daily truck traffic
  • 79,842Total future (year 1977) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Gobles
  • No street view available for this location

New bridges in Gobles, MI - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21930-1939
  • 11940-1949
  • 21950-1959
  • 31960-1969
  • 31970-1979
  • 11980-1989
  • 21990-1999
  • 82000-2009
  • 22010-2019
Reconstructed bridges in Gobles, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 12000-2009
  • 12010-2019
  • 12020-2022
Average Bridge Daily Traffic in Gobles, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.3%Excellent
  • 56.5%Good
  • 26.1%Satisfactory
  • 13.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 4.3%Excellent
  • 34.8%Very good
  • 17.4%Good
  • 30.4%Satisfactory
  • 8.7%Fair
  • 4.3%Critical
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 21.7%Very good
  • 39.1%Good
  • 26.1%Satisfactory
  • 8.7%Fair
  • 4.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 20.8%Very good
  • 41.7%Good
  • 29.2%Satisfactory
  • 8.3%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 452,  Location: 0.3 MI S OF US-23 (Lat: 44.001678,  Lng: -83.926900),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 235 (year 1998),  Average Future Daily Traffic: 150 (year 1977),  Design Load: HS 20+Mod,  Features Intersected: N BR PINE RIVER,  Facility Carried by Structure: FOCO ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.758,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1514,  Location: 6.8 MI N OF M-27 (Lat: 45.556233,  Lng: -84.620428),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 7.56m (24.80ft),  Average Daily Traffic: 110 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 180 (year 2007),  Design Load: H 15,  Features Intersected: I-75,  Facility Carried by Structure: INDIAN TRAIL RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.660,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1563,  Location: 4.8 MI S OF PARADISE (Lat: 46.556517,  Lng: -85.031383),  Route carried "on" structure: State highway 123,  Year Built: 1952,  Status: Open,  Structure Length: 8.53m (27.99ft),  Average Daily Traffic: 903 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,872 (year 2018),  Design Load: H 15,  Features Intersected: TAHQUAMENON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 51.507,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 317,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Navigation Control: Yes ( Vertical Clearance: 0.3m (1.0ft), Horizontal Clearance: 16.5m (54.1ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2020,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1565,  Location: 2.0 MI N OF M-28 (Lat: 46.371325,  Lng: -85.047797),  Route carried "on" structure: State highway 123,  Year Built: 1964,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 719 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 819 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: E BR TAHQUEMENON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 27.926,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 317,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.0m (29.5ft),  Curb-To-Curb Width: 23.4m (76.8ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 2209,  Location: 3 MI N OF NORWAY (Lat: 45.827181,  Lng: -87.897089),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 199 (year 2003),  Truck Traffic: 3%,  Average Future Daily Traffic: 245 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: PINE CREEK,  Facility Carried by Structure: DISTRICT 5 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.320,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4516,  Location: SOUTH OF JACKSON CITY LIM (Lat: 42.205075,  Lng: -84.405561),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 1,000 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,200 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: PROBERT ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.159,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4517,  Location: .5 MI N OF VANDERCOOK LAK (Lat: 42.207864,  Lng: -84.395664),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 1,577 (year 2004),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,800 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: PARK DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.275,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.7m (41.7ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4518,  Location: 1.5 MI S VANDERCOOK LAKE (Lat: 42.169083,  Lng: -84.383839),  Route carried "on" structure: County highway ,  Year Built: 2007,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 934 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,140 (year 2026),  Design Load: HS 20,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: DRAPER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.826,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 83.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4519,  Location: 0.4 MI. SOUTH OF JACKSON (Lat: 42.216469,  Lng: -84.365969),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 889 (year 2004),  Average Future Daily Traffic: 1,500 (year 2017),  Design Load: HS 20,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: S MERIDIAN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.230,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Inventory Rating: 60.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4521,  Location: 2.7 MI WEST OF JACKSON (Lat: 42.241497,  Lng: -84.488672),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,079 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,453 (year 2033),  Features Intersected: SANDSTONE CREEK,  Facility Carried by Structure: OBRIEN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.979,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4522,  Location: 0.6 MI NORTH OF CONCORD (Lat: 42.188778,  Lng: -84.661353),  Route carried "on" structure: County highway ,  Year Built: 1933,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 250 (year 2010),  Average Future Daily Traffic: 500 (year 2014),  Features Intersected: N BRANCH KALAMAZOO RIVER,  Facility Carried by Structure: CORNELL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.286,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Good,  Channel: Poor,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 62.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.00m (13.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $350,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $450,000 ( Estimate for 2014),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4523,  Location: 1.0 MI NORTH OF CONCORD (Lat: 42.196092,  Lng: -84.658889),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 150 (year 2014),  Average Future Daily Traffic: 200 (year 2034),  Design Load: Greater than HL93,  Features Intersected: N BRANCH KALAMAZOO RIVER,  Facility Carried by Structure: WARNER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.219,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4524,  Location: 1.4 MI EAST OF CONCORD (Lat: 42.176578,  Lng: -84.608639),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 726 (year 2008),  Average Future Daily Traffic: 886 (year 2028),  Design Load: H 20,  Features Intersected: N BR OF KALAMAZOO RIVER,  Facility Carried by Structure: PARSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.027,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 91.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4525,  Location: 2.5 MI S 1.8 MI W PULASKI (Lat: 42.077997,  Lng: -84.674978),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 100 (year 2002),  Average Future Daily Traffic: 150 (year 2022),  Design Load: HS 20,  Features Intersected: S BRANCH KALAMAZOO RIVER,  Facility Carried by Structure: GOOSE LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.896,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 58.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 41.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 4526,  Location: 2.5 M W & 1.0 M S PULASKI (Lat: 42.097942,  Lng: -84.691953),  Route carried "on" structure: County highway 3812,  Year Built: 1938,  Status: Closed,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 150 (year 2002),  Average Future Daily Traffic: 175 (year 2022),  Features Intersected: S BRANCH KALAMAZOO RIVER,  Facility Carried by Structure: HANOVER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.539,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Critical,  Substructure: Fair,  Channel: Poor,  Operating Rating: 19.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 11.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of replacement,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.13m (3.71ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $100,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $125,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 4528,  Location: 3 M S 1 M E VANDERCOOK LA (Lat: 42.153244,  Lng: -84.381617),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 150 (year 2004),  Average Future Daily Traffic: 75 (year 2022),  Design Load: HS 25 or greater,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: LOOMIS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.575,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.2m (66.3ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 83.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5101,  Location: 0.07 MI W OF SUMMIT AVE (Lat: 43.146481,  Lng: -85.564419),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 2,598 (year 2004),  Average Future Daily Traffic: 4,420 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: ROGUE RIVER,  Facility Carried by Structure: 12 MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.005,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5827,  Location: SEC 2 DEERFIELD TWP (Lat: 42.775864,  Lng: -83.833342),  Route carried "on" structure: County highway 4794,  Year Built: 1981,  Status: Open,  Structure Length: 2.43m (7.97ft),  Average Daily Traffic: 1,760 (year 2015),  Average Future Daily Traffic: 1,900 (year 2045),  Design Load: HS 20,  Features Intersected: NORTH ORE CREEK,  Facility Carried by Structure: BENNETT LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.153,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.0m (78.7ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5892,  Location: SEC 5-6 TYRONE TWP (Lat: 42.767100,  Lng: -83.785858),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 580 (year 2014),  Average Future Daily Traffic: 625 (year 2044),  Design Load: HS 20,  Features Intersected: RUNYAN CREEK,  Facility Carried by Structure: LINDEN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.578,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6196,  Location: 0.1 MI WEST OF UTICA RD (Lat: 42.566672,  Lng: -82.970731),  Route carried "on" structure: County highway 2058,  Year Built: 1969,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 5.87m (19.26ft),  Average Daily Traffic: 21,115 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 28,442 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: RED RUN DRAIN,  Facility Carried by Structure: WB METRO PARKWAY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.545,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 80,  Subroute: 2),  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.6m (57.7ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: August 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6197,  Location: 0.75 MI WEST OF M-97 (Lat: 42.568606,  Lng: -82.928725),  Route carried "on" structure: County highway 2058,  Year Built: 1952,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 16,440 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 22,145 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: HARRINGTON DRAIN,  Facility Carried by Structure: EB METRO PARKWAY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.170,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 80,  Subroute: 8),  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.2m (33.5ft),  Curb-To-Curb Width: 15.3m (50.2ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 91.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 654,  Location: 6 MILES S OF GREENWOOD (Lat: 46.397728,  Lng: -87.768856),  Route carried "on" structure: County highway 5231,  Year Built: 2008,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 1,360 (year 2007),  Average Future Daily Traffic: 1,660 (year 2027),  Design Load: HS 20,  Features Intersected: M BR ESCANABA RIVER,  Facility Carried by Structure: COUNTY RD 581
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.448,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 49.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 655,  Location: 4.5 MI N OF US41 (Lat: 46.581900,  Lng: -87.997461),  Route carried "on" structure: County highway 5210,  Year Built: 1926,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 200 (year 2001),  Average Future Daily Traffic: 200 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: PESHEKEE RIVER,  Facility Carried by Structure: COUNTY HWY 607
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.027,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10727,  Location: 1.6 MI W OF M-40 (Lat: 42.302792,  Lng: -85.918019),  Route carried "on" structure: State highway 43,  Year Built: 1948,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 6,722 (year 2014),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,730 (year 2034),  Design Load: HS 20,  Features Intersected: BRANDYWINE CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 33.064,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 57,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 13331,  Location: WAVERLY TWP SEC 3/10 (Lat: 42.317350,  Lng: -85.919303),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 208 (year 2005),  Average Future Daily Traffic: 375 (year 2025),  Design Load: HS 20,  Features Intersected: BRANDWINE CREEK,  Facility Carried by Structure: 28TH AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.738,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.6m (21.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Gobles, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.