Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Farmersville, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 108ft / 32.7mTotal length
  • $1,377,000Total costs
  • 81,758Total average daily traffic
  • 9,881Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Farmersville
  • No street view available for this location

New bridges in Farmersville, PA - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 11900-1909
  • 21950-1959
  • 41970-1979
  • 11980-1989
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Farmersville, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 11990-1999
Average Bridge Daily Traffic in Farmersville, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 16.7%Excellent
  • 33.3%Good
  • 50.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Excellent
  • 57.1%Good
  • 14.3%Satisfactory
  • 14.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 42.9%Good
  • 28.6%Satisfactory
  • 14.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 37.5%Good
  • 25.0%Satisfactory
  • 37.5%Fair
Find on map >>   Show street view

Structure Number: 21099,  Location: 1 MI. S.W. OF US 322 (Lat: 40.151892,  Lng: -76.163369),  Route carried "on" structure: State highway ,  Year Built: 1970,  Status: Open,  Structure Length: 7.59m (24.90ft),  Average Daily Traffic: 958 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,287 (year 2032),  Design Load: HS 20,  Features Intersected: 222NB 222SB,  Facility Carried by Structure: 1076;T664;Peach Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.30m (27.23ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $26,000,  Roadway Improvement Cost: $77,000,  Total Project Cost: $353,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 21205,  Location: 0.5 mi.S.E. of Hinkletown (Lat: 40.142289,  Lng: -76.109908),  Route carried "on" structure: US 322,  Year Built: 1954,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 9,320 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 12,498 (year 2032),  Design Load: HS 20,  Features Intersected: Trib to Conestoga River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.976,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 21386,  Location: 1.5 mi.W of Martindale (Lat: 40.156139,  Lng: -76.114447),  Route carried "on" structure: State highway ,  Year Built: 1952,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 4,017 (year 2022),  Truck Traffic: 14%,  Average Future Daily Traffic: 4,850 (year 2032),  Design Load: HS 20,  Features Intersected: Muddy Creek,  Facility Carried by Structure: Martindale Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.722,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.70m (21.98ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $37,000,  Roadway Improvement Cost: $109,000,  Total Project Cost: $500,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 21396,  Location: 1MI NOF FAIRMONT (Lat: 40.140450,  Lng: -76.151928),  Route carried "on" structure: State highway ,  Year Built: 1846,  Year Reconstructed: 1997,  Status: Posted for load,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 962 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 200 (year 2032),  Design Load: H 20,  Features Intersected: CONESTOGA RIVER,  Facility Carried by Structure: SR1013 CiderMillRd
Minimum Vertical Clearance: 3.61m (11.84ft),  Kilometerpoint: 16.443,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.5m (86.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 3.9m (12.8ft),  Out-to-Out Width: 4.0m (13.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 88.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 3.50m (11.48ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: March 2020,  Other Special Inspection Date: March 2021,  Bridge Improvement Cost: $39,000,  Roadway Improvement Cost: $114,000,  Total Project Cost: $524,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 21887,  Location: .45 MILES SOUTH OF SR1010 (Lat: 40.150672,  Lng: -76.103775),  Route carried "on" structure: City street ,  Year Built: 1973,  Status: Open,  Structure Length: 3.17m (10.40ft),  Average Daily Traffic: 680 (year 2012),  Truck Traffic: 5%,  Average Future Daily Traffic: 910 (year 2032),  Design Load: H 20,  Features Intersected: CONESTOGA RIVER,  Facility Carried by Structure: KURTZ ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.20m (10.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 41214,  Location: 0.5 mi.N.W. of Hinkletown (Lat: 40.153106,  Lng: -76.127636),  Route carried "on" structure: US 322,  Year Built: 2001,  Status: Open,  Structure Length: 7.99m (26.21ft),  Average Daily Traffic: 15,934 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 27,414 (year 2032),  Design Load: HL 93,  Features Intersected: Conestoga River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.987,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.90m (29.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 53875,  Location: 0.8 MI NW OF FARMERSVILLE (Lat: 40.134906,  Lng: -76.174114),  Route carried "on" structure: State highway ,  Year Built: 2018,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 2,044 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,840 (year 2032),  Design Load: HL 93,  Features Intersected: CONESTOGA RIVER,  Facility Carried by Structure: Farmersville Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.192,  Lanes on structure: 2,  Owner: State Highway Agency,  Maintenance Responsibility: Private,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 57596,  Location: NORTH OF CENTER SQUARE RD (Lat: 40.116308,  Lng: -76.188444),  Route carried "on" structure: City street ,  Year Built: 1901,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 100 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 200 (year 2040),  Features Intersected: GROFF CREEK,  Facility Carried by Structure: MAPLE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 0.3m (1.0ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 57598,  Location: NORTH OF CENTER SQUARE RD (Lat: 40.117092,  Lng: -76.177222),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 200 (year 2020),  Average Future Daily Traffic: 400 (year 2040),  Features Intersected: GROFF CREEK,  Facility Carried by Structure: BRETHREN CHURCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 21099,  Location: 1 MI. S.W. OF US 322 (Lat: 40.151892,  Lng: -76.163369),  Route carried "under" structure: US 222,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 23,942 (year 2020),  Truck Traffic: 13%,  Features Intersected: 222NB 222SB,  Facility Carried by Structure: 1076;T664;Peach Rd
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 62.924,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 21099,  Location: 1 MI. S.W. OF US 322 (Lat: 40.151892,  Lng: -76.163369),  Route carried "under" structure: US 222,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 23,601 (year 2020),  Truck Traffic: 14%,  Features Intersected: 222NB 222SB,  Facility Carried by Structure: 1076;T664;Peach Rd
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 62.985,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Discuss Farmersville, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.