  • National Bridge Inventory (NBI) Statistics
  • 19Number of bridges
  • 541ft / 165mTotal length
  • $1,594,000Total costs
  • 217,200Total average daily traffic
  • 33,415Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Fairmont City
  • No street view available for this location

New bridges in Fairmont City, IL - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 21930-1939
  • 11940-1949
  • 61960-1969
  • 51980-1989
  • 32010-2019
Reconstructed bridges in Fairmont City, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 11990-1999
Average Bridge Daily Traffic in Fairmont City, IL
Average Bridge Truck Traffic in Fairmont City, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Very good
  • 27.3%Good
  • 27.3%Satisfactory
  • 27.3%Fair
  • 9.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 18.2%Very good
  • 18.2%Good
  • 27.3%Satisfactory
  • 27.3%Fair
  • 9.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.2%Very good
  • 36.4%Good
  • 36.4%Satisfactory
  • 9.1%Serious
Find on map >>   Show street view

Structure Number: 600006,  Location: N OF FAIRMONT CITY (Lat: 38.662672,  Lng: -90.093108),  Route carried "on" structure: Interstate 55,  Year Built: 1961,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 25,850 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 24,857 (year 2032),  Design Load: HS 20,  Features Intersected: ILL 111,  Facility Carried by Structure: FAI 70 EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.074,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: September 2021,  Other Special Inspection Date: March 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 600007,  Location: N OF FAIRMONT CITY (Lat: 38.662669,  Lng: -90.092519),  Route carried "on" structure: Interstate 55,  Year Built: 1961,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 25,850 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 24,857 (year 2032),  Design Load: HS 20,  Features Intersected: ILL 111,  Facility Carried by Structure: FAI 70 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.106,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: September 2021,  Other Special Inspection Date: March 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 600208,  Location: .75 MI EAST ILL 111 (Lat: 38.662589,  Lng: -90.078131),  Route carried "on" structure: Interstate 55,  Year Built: 1980,  Status: Open,  Structure Length: 12.53m (41.11ft),  Average Daily Traffic: 25,850 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 24,857 (year 2032),  Design Load: HS 20,  Features Intersected: A&S RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.152,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 600209,  Location: .75 MI EAST ILL 111 (Lat: 38.662589,  Lng: -90.077983),  Route carried "on" structure: Interstate 55,  Year Built: 1980,  Status: Open,  Structure Length: 12.53m (41.11ft),  Average Daily Traffic: 25,850 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 24,857 (year 2032),  Design Load: HS 20,  Features Intersected: A&S RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.169,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 820024,  Location: 0.4 M E E ST LOUIS (Lat: 38.643161,  Lng: -90.130692),  Route carried "on" structure: Other road ,  Year Built: 1960,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 13.96m (45.80ft),  Average Daily Traffic: 7,600 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 10,251 (year 2032),  Design Load: HS 20,  Features Intersected: DRNG CANAL & I-55/70,  Facility Carried by Structure: RAMP TO IL 203 NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 10070040,  Subroute: 20),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 66.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 13.96m (45.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $1,141,000,  Roadway Improvement Cost: $114,000,  Total Project Cost: $1,255,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 820029,  Location: 0.1 M N OLD US 40 (Lat: 38.642747,  Lng: -90.127231),  Route carried "on" structure: State highway 203,  Year Built: 1960,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 4,000 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 4,132 (year 2032),  Design Load: HS 20,  Features Intersected: DRNG TO CAHOKIA CNL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.097,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 820031,  Location: 0.5 M E JCT ILL 203 (Lat: 38.641847,  Lng: -90.123997),  Route carried "on" structure: Other road ,  Year Built: 1947,  Status: Posted for load,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 3,600 (year 2018),  Truck Traffic: 17%,  Average Future Daily Traffic: 4,655 (year 2032),  Design Load: HS 20,  Features Intersected: SCHOENBERGER CK,  Facility Carried by Structure: COLLINSVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.274,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.98m (3.22ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2022,  Bridge Improvement Cost: $304,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $339,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 820098,  Location: N EDGE WASHINGTON PK (Lat: 38.645200,  Lng: -90.093181),  Route carried "on" structure: State highway 111,  Year Built: 1935,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 20.86m (68.44ft),  Average Daily Traffic: 3,050 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,079 (year 2032),  Design Load: HS 20,  Features Intersected: CONRAIL & B&O RR'S
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.166,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Serious,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 3 months,  Inspection Date: July 2021,  Other Special Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 820248,  Location: 1MI S MADISON CO LN (Lat: 38.643656,  Lng: -90.047053),  Route carried "on" structure: Interstate 255,  Year Built: 1985,  Status: Open,  Structure Length: 67.48m (221.39ft),  Average Daily Traffic: 21,700 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 24,215 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: BLACK LN/B&O/CONRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.804,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 18,  Length of Maximum Span: 40.2m (131.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 820328,  Location: 0.8 mi N of I-55/64 (Lat: 38.641692,  Lng: -90.154242),  Route carried "on" structure: Other road ,  Year Built: 2013,  Status: Open,  Structure Length: 5.16m (16.93ft),  Average Daily Traffic: 3,050 (year 2018),  Truck Traffic: 32%,  Average Future Daily Traffic: 1,402 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: RELOCATED I-70,  Facility Carried by Structure: REL IL 3 -Packers
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.205,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.9m (94.8ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 52.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 820329,  Location: 0.8 mi N of I-55/64 (Lat: 38.640803,  Lng: -90.155667),  Route carried "on" structure: Other road ,  Year Built: 2013,  Status: Open,  Structure Length: 12.03m (39.47ft),  Average Daily Traffic: 3,050 (year 2018),  Truck Traffic: 32%,  Average Future Daily Traffic: 1,870 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: ST CLAIR AV &TRRA RR,  Facility Carried by Structure: RELOCATED IL 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.366,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 43.2m (141.7ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 82201,  Location: 0.3 M N NATIONAL CTY (Lat: 38.643794,  Lng: -90.159208),  Route carried "on" structure: State highway 3,  Year Built: 1935,  Status: Open,  Structure Length: 1.45m (4.76ft),  Average Daily Traffic: 4,850 (year 2021),  Truck Traffic: 22%,  Average Future Daily Traffic: 6,590 (year 2032),  Features Intersected: CAHOKIA CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 237.694,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 82.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 600006,  Location: N OF FAIRMONT CITY (Lat: 38.662894,  Lng: -90.093036),  Route carried "under" structure: State highway 111,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 4,100 (year 2021),  Truck Traffic: 10%,  Features Intersected: ILL 111,  Facility Carried by Structure: FAI 70 EB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 7.371,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.2m (53.1ft)

Find on map >>   Show street view

Structure Number: 600007,  Location: N OF FAIRMONT CITY (Lat: 38.663061,  Lng: -90.092986),  Route carried "under" structure: State highway 111,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 4,100 (year 2021),  Truck Traffic: 10%,  Features Intersected: ILL 111,  Facility Carried by Structure: FAI 70 WB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 7.387,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.2m (53.1ft)

Find on map >>   Show street view

Structure Number: 820247,  Location: 1M S MADISON CO LINE (Lat: 38.643961,  Lng: -90.047072),  Route carried "under" structure: Other road ,  Year Built: 1985,  Structure Length: 0. m,  Average Daily Traffic: 2,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: BLACK LN-B&O-CONRAIL,  Facility Carried by Structure: FAI 255 SB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 1.625,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.2m (131.9ft)

Find on map >>   Show street view

Structure Number: 820248,  Location: 1MI S MADISON CO LN (Lat: 38.643656,  Lng: -90.047053),  Route carried "under" structure: Other road ,  Year Built: 1985,  Structure Length: 0. m,  Average Daily Traffic: 2,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: BLACK LN/B&O/CONRAIL,  Facility Carried by Structure: FAI 255 NB
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 1.641,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.2m (131.9ft)

Find on map >>   Show street view

Structure Number: 820328,  Location: 0.8 mi N of I-55/64 (Lat: 38.641914,  Lng: -90.154447),  Route carried "under" structure: Interstate 70,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 44,300 (year 2019),  Truck Traffic: 14%,  Features Intersected: RELOCATED I-70,  Facility Carried by Structure: REL IL 3 -Packers
Minimum Vertical Clearance: 6.20m (20.34ft),  Kilometerpoint: 2.591,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>   Show street view

Structure Number: 829903,  Location: E. ST. LOUIS (Lat: 38.637325,  Lng: -90.134300),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 2,900 (year 2018),  Truck Traffic: 13%,  Features Intersected: 9TH ST FAU 9213,  Facility Carried by Structure: TERMINAL R.R.
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 2.398,  Lanes under structure: 2,  Material/Design: Concrete,  Length of Maximum Span: 10.4m (34.1ft)

Find on map >>   Show street view

Structure Number: 829904,  Location: E. ST. LOUIS (Lat: 38.637778,  Lng: -90.133681),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 2,900 (year 2018),  Truck Traffic: 13%,  Features Intersected: FAU 9213 9TH ST,  Facility Carried by Structure: RAILROAD
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 2.478,  Lanes under structure: 2,  Material/Design: Concrete,  Length of Maximum Span: 13.1m (43.0ft)