  • 17Number of bridges
  • 89ft / 27.4mTotal length
  • $2,193,000Total costs
  • 81,759Total average daily traffic
  • 4,243Total average daily truck traffic
  • 109,527Total future (year 2022) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Cheyney University
  • No street view available for this location

New bridges in Cheyney University, PA - historical statistics
  • New bridges - historical statistics
  • 31910-1919
  • 11920-1929
  • 11930-1939
  • 21960-1969
  • 21970-1979
  • 11980-1989
  • 31990-1999
  • 42000-2009
Reconstructed bridges in Cheyney University, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 11980-1989
  • 11990-1999
  • 22000-2009
Average Bridge Daily Traffic in Cheyney University, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.7%Very good
  • 61.5%Good
  • 15.4%Satisfactory
  • 7.7%Fair
  • 7.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 31.3%Very good
  • 37.5%Good
  • 12.5%Satisfactory
  • 6.3%Fair
  • 6.3%Poor
  • 6.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.5%Very good
  • 37.5%Good
  • 37.5%Satisfactory
  • 6.3%Fair
  • 6.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.3%Very good
  • 6.3%Good
  • 18.8%Satisfactory
  • 50.0%Fair
  • 18.8%Poor
Find on map >>   Show street view

Structure Number: 9925,  Location: NEAR WEST CHESTER 32K9 (Lat: 39.965556,  Lng: -75.544664),  Route carried "on" structure: State highway 3,  Year Built: 1960,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 25,960 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 34,646 (year 2032),  Design Load: HS 20,  Features Intersected: EAST BR.CHESTER CREEK,  Facility Carried by Structure: WEST CHESTER PIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.924,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 23 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10285,  Location: NR.CONRAIL BRIDGE 41J03 (Lat: 39.931600,  Lng: -75.550758),  Route carried "on" structure: State highway 926,  Year Built: 1911,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 9,266 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,469 (year 2032),  Design Load: H 15,  Features Intersected: BRANCH CHESTER CREEK,  Facility Carried by Structure: STREET ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.354,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Masonry,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 6.3m (20.7ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.80m (5.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $11,000,  Roadway Improvement Cost: $31,000,  Total Project Cost: $144,000
Find on map >>   Show street view

Structure Number: 10286,  Location: WESTTOWN STATION 41J3 (Lat: 39.932097,  Lng: -75.549597),  Route carried "on" structure: State highway 926,  Year Built: 1987,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 9,266 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,469 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: WEST CHESTER RR (SEPTA),  Facility Carried by Structure: STREET ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.354,  Lanes on structure: 2,  Owner: Railroad,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.80m (5.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10287,  Location: WEST OF TR-352 41G11 (Lat: 39.936047,  Lng: -75.541103),  Route carried "on" structure: State highway 926,  Year Built: 2004,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 10,617 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,541 (year 2032),  Design Load: HL 93,  Features Intersected: CHESTER CREEK,  Facility Carried by Structure: STREET ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.432,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.20m (10.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $67,000,  Roadway Improvement Cost: $197,000,  Total Project Cost: $902,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10784,  Location: 0.5 Mi N of PA-3 3584-C5 (Lat: 39.972883,  Lng: -75.548731),  Route carried "on" structure: City street ,  Year Built: 1920,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 1,575 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,800 (year 2035),  Features Intersected: TRIB TO CHESTER CREEK,  Facility Carried by Structure: RESERVOIR ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 5.8m (19.0ft),  Curb-To-Curb Width: 4.7m (15.4ft),  Out-to-Out Width: 5.7m (18.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Fair,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.80m (2.62ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $12,000,  Roadway Improvement Cost: $36,000,  Total Project Cost: $165,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10785,  Location: 0.4 MI S SR 3, 3584-C7 (Lat: 39.960544,  Lng: -75.545622),  Route carried "on" structure: City street ,  Year Built: 1916,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 2,300 (year 2010),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,700 (year 2030),  Design Load: HS 20,  Features Intersected: EAST BRANCH CHESTER CRK.,  Facility Carried by Structure: WESTTOWN WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $18,000,  Roadway Improvement Cost: $52,000,  Total Project Cost: $238,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10861,  Location: .5 Mi N PA-3 3585-B5 (Lat: 39.972181,  Lng: -75.492167),  Route carried "on" structure: City street ,  Year Built: 1930,  Year Reconstructed: 1993,  Status: Posted for load,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 500 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 550 (year 2035),  Design Load: H 20,  Features Intersected: RIDLEY CREEK,  Facility Carried by Structure: GARRETT MILL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 4.0m (13.1ft),  Out-to-Out Width: 4.4m (14.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 20.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: August 2019,  Critical Feature Inspection Date: August 2020,  Other Special Inspection Date: August 2020,  Bridge Improvement Cost: $4,000,  Roadway Improvement Cost: $31,000,  Total Project Cost: $53,000,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 15358,  Location: CONCORD;THORNBURY 32A09 (Lat: 39.894719,  Lng: -75.536444),  Route carried "on" structure: State highway ,  Year Built: 1973,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 984 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 875 (year 2032),  Design Load: HS 20,  Features Intersected: WEST BRANCH CHESTER CR.,  Facility Carried by Structure: MILL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Operating Rating: 84.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15361,  Location: 1MI.S.CHEYNEY COL. 32C03 (Lat: 39.929519,  Lng: -75.523231),  Route carried "on" structure: State highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 3,064 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,430 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: CHESTER CREEK,  Facility Carried by Structure: CHEYNEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.133,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 97.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 15362,  Location: 1MI.S.CHEYNEY COL. 32C03 (Lat: 39.929856,  Lng: -75.523431),  Route carried "on" structure: State highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 3,064 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,430 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: BR.CHESTER CK.(FLD.PLN.),  Facility Carried by Structure: CHEYNEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.133,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 97.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 15366,  Location: 1MI.N.US 1 32A09/3694-D7 (Lat: 39.895942,  Lng: -75.538325),  Route carried "on" structure: State highway ,  Year Built: 1969,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 7,663 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,604 (year 2032),  Design Load: HL 93,  Features Intersected: WEST BR OF CHESTER CREEK,  Facility Carried by Structure: BRINTON LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.228,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 15385,  Location: .8MI.SOUTH PA-926 17-D4 (Lat: 39.932697,  Lng: -75.516933),  Route carried "on" structure: County highway ,  Year Built: 1914,  Status: Posted for load,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 272 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 340 (year 2032),  Design Load: H 20,  Features Intersected: CHESTER CREEK,  Facility Carried by Structure: STATION ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Fair,  Superstructure: Serious,  Substructure: Poor,  Channel: Poor,  Operating Rating: 6.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 3.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 2.90m (9.51ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: November 2019,  Other Special Inspection Date: August 2021,  Bridge Improvement Cost: $51,000,  Roadway Improvement Cost: $151,000,  Total Project Cost: $691,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 40738,  Location: WESTTOWN 41H2 (Lat: 39.934881,  Lng: -75.558267),  Route carried "on" structure: State highway ,  Year Built: 1999,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 2,169 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,397 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: CHESTER CREEK,  Facility Carried by Structure: WESTBOURNE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.257,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Poor,  Operating Rating: 98.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.00m (6.56ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42622,  Location: WESTTOWN 32K12 (Lat: 39.952233,  Lng: -75.548664),  Route carried "on" structure: State highway ,  Year Built: 2004,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 1,823 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 3,926 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: EAST BR CHESTER CREEK,  Facility Carried by Structure: WESTTOWN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.613,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Superstructure: Good,  Substructure: Very good,  Channel: Fair,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.70m (12.14ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 4405,  Location: THORNBURY TOWNSHIP 41K3 (Lat: 39.930706,  Lng: -75.545386),  Route carried "on" structure: State highway ,  Year Built: 2007,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 2,419 (year 2022),  Truck Traffic: 9%,  Average Future Daily Traffic: 2,452 (year 2032),  Design Load: H 15,  Features Intersected: BRANCH CHESTER CREEK,  Facility Carried by Structure: THORNTON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.384,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Superstructure: Good,  Substructure: Very good,  Channel: Fair,  Operating Rating: 85.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 60.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 45266,  Location: 2.5 Mi. SE PA-926 17-F5 (Lat: 39.931019,  Lng: -75.504639),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 2.23m (7.32ft),  Average Daily Traffic: 617 (year 2017),  Truck Traffic: 11%,  Average Future Daily Traffic: 678 (year 2022),  Design Load: HL 93,  Features Intersected: CHESTER CREEK,  Facility Carried by Structure: LOCKSLEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 54889,  Location: NE OF VALLEY RD (Lat: 39.957300,  Lng: -75.487900),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 200 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 220 (year 2028),  Design Load: HS 20,  Features Intersected: BR. OF RIDLEY CREEK,  Facility Carried by Structure: STACKHOUSE MILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020