Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Chalfont, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 69ft / 21.3mTotal length
  • $1,080,000Total costs
  • 171,129Total average daily traffic
  • 15,469Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Chalfont
  • No street view available for this location

New bridges in Chalfont, PA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21950-1959
  • 11970-1979
  • 11980-1989
  • 22000-2009
  • 42010-2019
Reconstructed bridges in Chalfont, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 11990-1999
Average Bridge Daily Traffic in Chalfont, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 75.0%Good
  • 12.5%Satisfactory
  • 12.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 37.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.5%Very good
  • 50.0%Good
  • 37.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 16.7%Very good
  • 33.3%Good
  • 16.7%Satisfactory
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 6906,  Location: 2.5MI.LR-09060 27K03 (Lat: 40.287708,  Lng: -75.209281),  Route carried "on" structure: State highway 152,  Year Built: 1912,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 16,567 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 20,603 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SEPTA(DOYLESTOWN LINE),  Facility Carried by Structure: MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.169,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Inventory Rating: 86.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7114,  Location: CHALFONT BOROUGH 27K02 (Lat: 40.291408,  Lng: -75.205728),  Route carried "on" structure: State highway ,  Year Built: 1970,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 5,070 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 6,763 (year 2032),  Design Load: H 20,  Features Intersected: NORTH BR NESHAMINY CREEK,  Facility Carried by Structure: FERRY RD./PARK AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.934,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.3m (73.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 5.60m (18.37ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Bridge Improvement Cost: $20,000,  Roadway Improvement Cost: $58,000,  Total Project Cost: $265,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 7495,  Location: WARRINGTON TWP. 28D07 (Lat: 40.263297,  Lng: -75.182597),  Route carried "on" structure: City street ,  Year Built: 2004,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 1,000 (year 2005),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,000 (year 2011),  Design Load: HL 93,  Features Intersected: MILL CREEK,  Facility Carried by Structure: PICKERTOWN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 96.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 3.10m (10.17ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $60,000,  Roadway Improvement Cost: $199,000,  Total Project Cost: $815,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7546,  Location: NEW BRITAIN TWP. 21J13 (Lat: 40.305500,  Lng: -75.211200),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 500 (year 2001),  Average Future Daily Traffic: 700 (year 2011),  Features Intersected: NORTH BR NESHAMINY CREEK,  Facility Carried by Structure: CREEK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Inventory Rating: 70.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.70m (8.86ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 28179,  Location: SOUTH OF FORT WASHINGTON (Lat: 40.293333,  Lng: -75.225000),  Route carried "on" structure: Interstate 276,  Year Built: 1954,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 2.23m (7.32ft),  Average Daily Traffic: 74,921 (year 2001),  Truck Traffic: 14%,  Average Future Daily Traffic: 103,041 (year 2030),  Design Load: HS 20,  Features Intersected: SR 0073
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 35 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 31.8m (104.3ft),  Out-to-Out Width: 33.5m (109.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.90m (9.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 44413,  Location: Peace Valley Park 21K12 (Lat: 40.312300,  Lng: -75.207575),  Route carried "on" structure: State highway ,  Year Built: 2005,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 5,694 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 8,703 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: North BR Neshaminy Creek,  Facility Carried by Structure: Callowhill Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.884,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 47587,  Location: .75MI E PA152 28C6/3033K7 (Lat: 40.272733,  Lng: -75.189278),  Route carried "on" structure: State highway ,  Year Built: 2012,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 4,038 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 376 (year 2032),  Design Load: HL 93,  Features Intersected: U.S. 202 PARKWAY,  Facility Carried by Structure: PICKERTOWN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 47702,  Location: 1 MI. E. PA152 3034A07 (Lat: 40.275292,  Lng: -75.185922),  Route carried "on" structure: US 202,  Year Built: 2012,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 15,724 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 22,856 (year 2037),  Design Load: HL 93,  Features Intersected: UNNAMED BR. NESH & WETLA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.050,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.0m

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 48473,  Location: .5 MI. S. PA152 3033G05 (Lat: 40.284800,  Lng: -75.208958),  Route carried "on" structure: State highway 152,  Year Built: 2014,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 16,864 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 23,546 (year 2032),  Design Load: HL 93,  Features Intersected: W. BR. NESHAMINY CREEK,  Facility Carried by Structure: BUTLER AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.913,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 28179,  Location: SOUTH OF FORT WASHINGTON (Lat: 40.293333,  Lng: -75.225000),  Route carried "under" structure: State highway 73,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 15,027 (year 2020),  Truck Traffic: 3%,  Features Intersected: SR 0073,  Facility Carried by Structure: PA TPK (I-276)
Minimum Vertical Clearance: 4.09m (13.42ft),  Kilometerpoint: 39.920,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Frame,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 47587,  Location: .75MI E PA152 28C6/3033K7 (Lat: 40.272733,  Lng: -75.189278),  Route carried "under" structure: US 202,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 15,724 (year 2020),  Truck Traffic: 8%,  Features Intersected: U.S. 202 PARKWAY,  Facility Carried by Structure: PICKERTOWN ROAD
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 2.813,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 21.9m (71.9ft)

Discuss Chalfont, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.