Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Catlin, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 112ft / 34.1mTotal length
  • 77,875Total average daily traffic
  • 25,021Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Catlin
  • No street view available for this location

New bridges in Catlin, IL - historical statistics
  • New bridges - historical statistics
  • 21950-1959
  • 51960-1969
  • 31980-1989
  • 11990-1999
  • 22000-2009
  • 12010-2019
Average Bridge Daily Traffic in Catlin, IL
Average Bridge Truck Traffic in Catlin, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 28.6%Very good
  • 28.6%Good
  • 14.3%Satisfactory
  • 28.6%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 42.9%Very good
  • 14.3%Satisfactory
  • 14.3%Fair
  • 28.6%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 42.9%Very good
  • 42.9%Good
  • 14.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 11.1%Excellent
  • 22.2%Very good
  • 11.1%Good
  • 33.3%Satisfactory
  • 22.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Good
  • 25.0%Satisfactory
  • 50.0%Fair
Find on map >>   Show street view

Structure Number: 920051,  Location: W OF DANVILLE (Lat: 40.123400,  Lng: -87.711725),  Route carried "on" structure: US 150,  Year Built: 1960,  Status: Open,  Structure Length: 6.84m (22.44ft),  Average Daily Traffic: 4,400 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,673 (year 2032),  Design Load: HS 20,  Features Intersected: I-74
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 346.466,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.3m (66.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 920099,  Location: W OF DANVILLE (Lat: 40.119536,  Lng: -87.702294),  Route carried "on" structure: Other road ,  Year Built: 1962,  Status: Open,  Structure Length: 7.49m (24.57ft),  Average Daily Traffic: 1,050 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,386 (year 2032),  Design Load: HS 15,  Features Intersected: FAI 74,  Facility Carried by Structure: Batestown (FAU 700
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.706,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.6m (67.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 920138,  Location: W EDGE OF CATLIN (Lat: 40.065153,  Lng: -87.717439),  Route carried "on" structure: Other road ,  Year Built: 1952,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 2,950 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 3,081 (year 2032),  Design Load: HS 20,  Features Intersected: BUTLER CREEK,  Facility Carried by Structure: FAS 512(CH8)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.612,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.7m (15.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 922005,  Location: 3.5 MI E OF OAKWOOD (Lat: 40.119047,  Lng: -87.721617),  Route carried "on" structure: US 150,  Year Built: 1953,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Future Daily Traffic: 3,646 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 345.404,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 923326,  Location: 2.5 MI N CATLIN (Lat: 40.102056,  Lng: -87.714678),  Route carried "on" structure: Other road ,  Year Built: 1982,  Status: Open,  Structure Length: 9.29m (30.48ft),  Average Daily Traffic: 750 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 719 (year 2032),  Design Load: HS 20,  Features Intersected: VERMILION RIVER,  Facility Carried by Structure: FAS 507(TR 210)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.044,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 923373,  Location: 2.6 MI N OF CATLIN (Lat: 40.101981,  Lng: -87.715953),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 150 (year 2019),  Average Future Daily Traffic: 163 (year 2032),  Design Load: HS 20,  Features Intersected: BUTLER BRANCH,  Facility Carried by Structure: TR 297
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.931,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 923421,  Location: 0.5 MI NW OF CATLIN (Lat: 40.078728,  Lng: -87.713750),  Route carried "on" structure: County highway ,  Year Built: 1993,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 61 (year 2032),  Design Load: HS 20,  Features Intersected: BUTLER BRANCH,  Facility Carried by Structure: TR 216
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 923505,  Location: 4 MI S CATLIN (Lat: 40.009561,  Lng: -87.720089),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 1.41m (4.63ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 20%,  Average Future Daily Traffic: 77 (year 2032),  Design Load: HS 20,  Features Intersected: FAYETTE CREEK,  Facility Carried by Structure: TR 373
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.665,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.3m (43.6ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 923511,  Location: 4.5 mi SW Catlin (Lat: 40.003700,  Lng: -87.727769),  Route carried "on" structure: County highway ,  Year Built: 2018,  Status: Open,  Structure Length: 1.44m (4.72ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 50 (year 2042),  Design Load: HS 25 or greater,  Features Intersected: Fayette Creek,  Facility Carried by Structure: TR 222
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.688,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 925014,  Location: 2.5 MI NW OF CATLIN (Lat: 40.102553,  Lng: -87.721114),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 150 (year 2019),  Average Future Daily Traffic: 163 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB SALT FK VERM R,  Facility Carried by Structure: TR 297
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.416,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 92604,  Location: N. CATLIN (Lat: 40.075372,  Lng: -87.705636),  Route carried "on" structure: Other road ,  Year Built: 2007,  Status: Open,  Structure Length: 2.06m (6.76ft),  Average Daily Traffic: 725 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 668 (year 2032),  Design Load: HS 20,  Features Intersected: BUTLER BRANCH,  Facility Carried by Structure: FAU 7060
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.336,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.9m (65.3ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 920005,  Location: W OF HILLERY (Lat: 40.124797,  Lng: -87.714797),  Route carried "under" structure: Interstate 74,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 25,100 (year 2021),  Truck Traffic: 32%,  Features Intersected: I-74,  Facility Carried by Structure: PEORIA & EASTERN R
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 340.560,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 27.2m (89.2ft)

Find on map >>   Show street view

Structure Number: 920051,  Location: W OF DANVILLE (Lat: 40.123464,  Lng: -87.711578),  Route carried "under" structure: Interstate 74,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 21,200 (year 2021),  Truck Traffic: 38%,  Features Intersected: I-74,  Facility Carried by Structure: US 150(FAU 7052)
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 340.818,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.3m (66.6ft)

Find on map >>   Show street view

Structure Number: 920099,  Location: W OF DANVILLE (Lat: 40.119536,  Lng: -87.702294),  Route carried "under" structure: Interstate 74,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 21,200 (year 2021),  Truck Traffic: 38%,  Features Intersected: FAI 74,  Facility Carried by Structure: Batestown (FAU 700
Minimum Vertical Clearance: 5.59m (18.34ft),  Kilometerpoint: 341.735,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 20.6m (67.6ft)

Discuss Catlin, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.