Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Beechwood, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 49ft / 14.6mTotal length
  • 146,471Total average daily traffic
  • 6,037Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Beechwood
  • No street view available for this location

New bridges in Beechwood, MI - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11960-1969
  • 61970-1979
  • 21980-1989
  • 11990-1999
  • 12000-2009
  • 12010-2019
Average Bridge Daily Traffic in Beechwood, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Very good
  • 50.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Very good
  • 33.3%Good
  • 16.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 16.7%Very good
  • 83.3%Good
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 54.5%Very good
  • 27.3%Good
  • 18.2%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Very good
  • 16.7%Good
  • 16.7%Satisfactory
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 8696,  Location: 0.6 MI N OF I-196 BL (Lat: 42.804778,  Lng: -86.085011),  Route carried "on" structure: US 31,  Year Built: 1984,  Status: Open,  Structure Length: 3.61m (11.84ft),  Average Daily Traffic: 35,990 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 51,200 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: LAKEWOOD BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.191,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 74,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 30.8m (101.0ft),  Out-to-Out Width: 34.8m (114.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 88,  Location: SECTION 33 PARK TOWNSHIP (Lat: 42.769594,  Lng: -86.197003),  Route carried "on" structure: County highway 2014,  Year Built: 1900,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,920 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,470 (year 2040),  Features Intersected: MONTELLO PARK DRAIN,  Facility Carried by Structure: SOUTH SHORE DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.431,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8802,  Location: 0.75 MILES E OF 152ND AVE (Lat: 42.804742,  Lng: -86.142753),  Route carried "on" structure: County highway 2014,  Year Built: 1974,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 10,320 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,640 (year 2040),  Design Load: HS 20,  Features Intersected: PINE CREEK,  Facility Carried by Structure: LAKEWOOD BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.258,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8803,  Location: 0.4 MILES E OF BEELINE RD (Lat: 42.804725,  Lng: -86.095747),  Route carried "on" structure: County highway 2014,  Year Built: 1974,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 28,150 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 50,800 (year 2040),  Design Load: HS 20,  Features Intersected: COUNTY DRAIN NO 40,  Facility Carried by Structure: LAKEWOOD BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.172,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 73,  Subroute: 10),  Owner: County Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8822,  Location: 0.32 MILES SOUTH OF 144TH (Lat: 42.825264,  Lng: -86.132561),  Route carried "on" structure: County highway 2014,  Year Built: 1994,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 13,070 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 23,600 (year 2040),  Design Load: HS 20,  Features Intersected: PINE CREEK,  Facility Carried by Structure: BUTTERNUT DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.331,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 2.8m (9.2ft),  Right: 0.0m,  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8885,  Location: SECTION 18 HOLLAND TWP (Lat: 42.826661,  Lng: -86.127581),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 13,227 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 23,890 (year 2039),  Design Load: H 20,  Features Intersected: PINE CREEK,  Facility Carried by Structure: RILEY ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.813,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 50.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8887,  Location: SECTION 7 HOLLAND TWP (Lat: 42.841175,  Lng: -86.129525),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 6,970 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,590 (year 2040),  Design Load: H 20,  Features Intersected: PINE CREEK,  Facility Carried by Structure: QUINCY STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.404,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Wood or Timber,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8889,  Location: SECTION 18 HOLLAND TWP (Lat: 42.818175,  Lng: -86.137806),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 5,395 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,740 (year 2039),  Design Load: HS 20,  Features Intersected: PINE CREEK,  Facility Carried by Structure: 144TH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.393,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.0m (32.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 889,  Location: SECTION 6 HOLLAND TWP (Lat: 42.848008,  Lng: -86.138033),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 3,123 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,640 (year 2039),  Design Load: HS 20,  Features Intersected: HARLEM DRAIN,  Facility Carried by Structure: 144TH AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.706,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.8m (9.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 50.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 89,  Location: SECTION 31 OLIVE TWP (Lat: 42.870772,  Lng: -86.139253),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,526 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,560 (year 2039),  Design Load: H 20,  Features Intersected: CRANBERRY DRAIN,  Facility Carried by Structure: 144TH AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.238,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Wood or Timber,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8907,  Location: SECTION 24 PARK TWP (Lat: 42.811958,  Lng: -86.149878),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 6,280 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,340 (year 2040),  Design Load: H 20,  Features Intersected: PINE CREEK,  Facility Carried by Structure: JAMES ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.807,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 13266,  Location: PARK TWP SEC 33 (Lat: 42.767708,  Lng: -86.197447),  Route carried "on" structure: County highway 2014,  Year Built: 2002,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 1,500 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,710 (year 2039),  Design Load: HS 20,  Features Intersected: KELLY LAKE DRAIN,  Facility Carried by Structure: 32ND STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 8696,  Location: 0.6 MI N OF I-196 BL (Lat: 42.804778,  Lng: -86.085011),  Route carried "under" structure: County highway 2014,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 18,000 (year 1995),  Truck Traffic: 1%,  Features Intersected: LAKEWOOD BLVD,  Facility Carried by Structure: US-31
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 10.051,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.9m (117.8ft)

Discuss Beechwood, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.