Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Barrington Hills, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 49ft / 14.6mTotal length
  • 84,725Total average daily traffic
  • 4,487Total average daily truck traffic
  • 93,480Total future (year 2032) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Barrington Hills
  • No street view available for this location

New bridges in Barrington Hills, IL - historical statistics
  • New bridges - historical statistics
  • 31920-1929
  • 11970-1979
  • 11980-1989
  • 11990-1999
  • 22000-2009
  • 22010-2019
Average Bridge Daily Traffic in Barrington Hills, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Good
  • 66.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 25.0%Good
  • 50.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Very good
  • 25.0%Good
  • 25.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 11.1%Very good
  • 33.3%Good
  • 33.3%Satisfactory
  • 22.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 33.3%Satisfactory
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 16058,  Location: 1.4 M W IL 59 (Lat: 42.120808,  Lng: -88.207481),  Route carried "on" structure: State highway 62,  Year Built: 1929,  Status: Posted for load,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 25,600 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,261 (year 2032),  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.654,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 161024,  Location: 4 M W IL 59 (Lat: 42.154275,  Lng: -88.211986),  Route carried "on" structure: Other road ,  Year Built: 1927,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 9,950 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,021 (year 2032),  Features Intersected: SPRING CREEK,  Facility Carried by Structure: LAKE COOK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.205,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.9m (16.1ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 30.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 162613,  Location: 0.1 M W IL 59 (Lat: 42.114142,  Lng: -88.179361),  Route carried "on" structure: State highway 62,  Year Built: 1997,  Status: Open,  Structure Length: 5.20m (17.06ft),  Average Daily Traffic: 31,300 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 34,402 (year 2032),  Features Intersected: RR - EJ&E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.192,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 4,  Length of Maximum Span: 19.4m (63.6ft),  Curb-To-Curb Width: 27.6m (90.6ft),  Out-to-Out Width: 29.6m (97.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162811,  Location: 1.8 M W IL 59 (Lat: 42.110333,  Lng: -88.211689),  Route carried "on" structure: State highway 68,  Year Built: 2009,  Status: Open,  Structure Length: 1.17m (3.84ft),  Average Daily Traffic: 6,950 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,137 (year 2032),  Design Load: HS 20,  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.198,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.8m (12.5ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2019,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 163275,  Location: 0.8 MI E BRINKER RD (Lat: 42.139781,  Lng: -88.151669),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 700 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 721 (year 2032),  Design Load: HS 20,  Features Intersected: FLINT CREEK,  Facility Carried by Structure: OTIS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.717,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 493057,  Location: 0.5M.N.LAKE COOK RD. (Lat: 42.163500,  Lng: -88.170469),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Future Daily Traffic: 278 (year 2032),  Design Load: HS 20,  Features Intersected: FLINT CREEK,  Facility Carried by Structure: OAK KNOLLS RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.274,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 493076,  Location: .1M E of Ridge Rd. (Lat: 42.165258,  Lng: -88.197350),  Route carried "on" structure: City street ,  Year Built: 1926,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 300 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,300 (year 2032),  Features Intersected: Flint Creek,  Facility Carried by Structure: Oak Knoll Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 6.2m (20.3ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 493077,  Location: 0.3 MI N LAKE-COOK R (Lat: 42.159225,  Lng: -88.150725),  Route carried "on" structure: Other road ,  Year Built: 1978,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,800 (year 2041),  Design Load: HS 20,  Features Intersected: FLINT CREEK TRIB,  Facility Carried by Structure: HART ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.044,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.5m (11.5ft),  Curb-To-Curb Width: 10.4m (34.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 496051,  Location: 0.25 Mi S OF US14 (Lat: 42.176131,  Lng: -88.185328),  Route carried "on" structure: Other road ,  Year Built: 2016,  Status: Open,  Structure Length: 1.17m (3.84ft),  Average Daily Traffic: 800 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,260 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Flint Creek,  Facility Carried by Structure: Cuba & Merry Oaks
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.175,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018
Find on map >>   Show street view

Structure Number: 563076,  Location: .25M W of Ridge Rd. (Lat: 42.168742,  Lng: -88.204475),  Route carried "on" structure: City street ,  Year Built: 2012,  Status: Open,  Structure Length: 0.93m (3.05ft),  Average Daily Traffic: 625 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,300 (year 2032),  Features Intersected: Spring Creek,  Facility Carried by Structure: Spring Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.265,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.9m (19.4ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 87.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 87.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Barrington Hills, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.