Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Bardolph, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 30Number of bridges
  • 354ft / 108mTotal length
  • $6,431,000Total costs
  • 425,350Total average daily traffic
  • 50,683Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bardolph
  • No street view available for this location

New bridges in Bardolph, IL - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21930-1939
  • 11940-1949
  • 31950-1959
  • 61960-1969
  • 61970-1979
  • 11980-1989
  • 41990-1999
  • 42000-2009
  • 22010-2019
Reconstructed bridges in Bardolph, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 31990-1999
  • 22000-2009
Average Bridge Daily Traffic in Bardolph, IL
Average Bridge Truck Traffic in Bardolph, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 27.3%Very good
  • 31.8%Good
  • 18.2%Satisfactory
  • 18.2%Fair
  • 4.5%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 27.3%Very good
  • 31.8%Good
  • 13.6%Satisfactory
  • 22.7%Fair
  • 4.5%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 31.8%Very good
  • 27.3%Good
  • 18.2%Satisfactory
  • 22.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 41.2%Very good
  • 23.5%Good
  • 17.6%Satisfactory
  • 17.6%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Very good
  • 60.0%Good
  • 20.0%Serious
Find on map >>   Show street view

Structure Number: 60055,  Location: 3.8 MI W IL 26 (Lat: 41.266925,  Lng: -89.398478),  Route carried "on" structure: Interstate 180,  Year Built: 1968,  Status: Open,  Structure Length: 10.01m (32.84ft),  Average Daily Traffic: 1,250 (year 2021),  Truck Traffic: 22%,  Average Future Daily Traffic: 1,230 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: I-180 NB Ent Ramp
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 14.918,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 48.8m (160.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 60056,  Location: 3.6 MI W IL 26 (Lat: 41.265161,  Lng: -89.395689),  Route carried "on" structure: Interstate 180,  Year Built: 1968,  Status: Open,  Structure Length: 7.13m (23.39ft),  Average Daily Traffic: 1,250 (year 2021),  Truck Traffic: 22%,  Average Future Daily Traffic: 1,230 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: I-180NB/WB Exit Ramp
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 15.176,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 160001,  Location: 2.1 M SW US 45 (Lat: 41.759247,  Lng: -87.907917),  Route carried "on" structure: Interstate 55,  Year Built: 1962,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 8.40m (27.56ft),  Average Daily Traffic: 59,650 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 78,383 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: JOLIET RD EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 445.615,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 6 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.2m (92.5ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 85.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160129,  Location: 1.4 M NW IL 64 (Lat: 41.925619,  Lng: -87.684253),  Route carried "on" structure: Interstate 90,  Year Built: 1958,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 8.87m (29.10ft),  Average Daily Traffic: 180,000 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 294,992 (year 2032),  Design Load: HS 20,  Features Intersected: FULLERTON AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 143.051,  Lanes on structure: 10,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 52.5m (172.2ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.7m (120.4ft),  Curb-To-Curb Width: 52.5m (172.2ft),  Out-to-Out Width: 54.3m (178.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.78m (28.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $2,609,000,  Roadway Improvement Cost: $261,000,  Total Project Cost: $4,226,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160285,  Location: 0.6 M E IL 50 (Lat: 41.506081,  Lng: -87.742269),  Route carried "on" structure: US 30,  Year Built: 1966,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 7.99m (26.21ft),  Average Daily Traffic: 35,200 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 27,913 (year 2032),  Design Load: HS 20,  Features Intersected: I- 57
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 226.799,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.6m (87.3ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.0m (101.7ft),  Curb-To-Curb Width: 26.6m (87.3ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160309,  Location: 0.7 M N FOSTER AVE (Lat: 41.982650,  Lng: -87.806936),  Route carried "on" structure: State highway 43,  Year Built: 1958,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 7.16m (23.49ft),  Average Daily Traffic: 28,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 29,046 (year 2032),  Design Load: HS 20,  Features Intersected: I- 90 JFK & CTA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.364,  Lanes on structure: 5,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.1m (69.2ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.1m (82.3ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 21.1m (69.2ft),  Out-to-Out Width: 27.1m (88.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 79.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.01m (23.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $1,470,000,  Roadway Improvement Cost: $147,000,  Total Project Cost: $2,205,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160321,  Location: 0.1 S 95TH ST (Lat: 41.717383,  Lng: -87.798575),  Route carried "on" structure: State highway 43,  Year Built: 1961,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 7.71m (25.30ft),  Average Daily Traffic: 38,600 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 31,724 (year 2032),  Design Load: HS 20,  Features Intersected: RR - CSXT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.592,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 500163,  Location: 0.75 MI N OF US 34 (Lat: 41.565344,  Lng: -89.061992),  Route carried "on" structure: Interstate 39,  Year Built: 1977,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 10,100 (year 2019),  Truck Traffic: 38%,  Average Future Daily Traffic: 8,936 (year 2032),  Design Load: HS 20,  Features Intersected: B & N RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 118.235,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 500164,  Location: 0.76 MI N OF US 34 (Lat: 41.565486,  Lng: -89.062006),  Route carried "on" structure: Interstate 39,  Year Built: 1977,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 10,100 (year 2019),  Truck Traffic: 38%,  Average Future Daily Traffic: 8,936 (year 2032),  Design Load: HS 20,  Features Intersected: B & N RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 118.251,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 500165,  Location: INTCHG US 34 & 1-39 (Lat: 41.554250,  Lng: -89.060819),  Route carried "on" structure: US 34,  Year Built: 1977,  Status: Open,  Structure Length: 6.51m (21.36ft),  Average Daily Traffic: 2,150 (year 2021),  Truck Traffic: 64%,  Average Future Daily Traffic: 3,016 (year 2032),  Design Load: HS 20,  Features Intersected: I-39/US 51
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 224.079,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 500257,  Location: 2.2 MI E OF IL 251 (Lat: 41.554817,  Lng: -89.093642),  Route carried "on" structure: US 34,  Year Built: 2018,  Status: Open,  Structure Length: 2.46m (8.07ft),  Average Daily Traffic: 4,850 (year 2021),  Truck Traffic: 73%,  Average Future Daily Traffic: 5,800 (year 2042),  Design Load: HS 25 or greater,  Features Intersected: LITTLE VERMILION
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 221.424,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.6m (77.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 503093,  Location: E 4TH N 4345 (Lat: 41.561603,  Lng: -89.089336),  Route carried "on" structure: City street ,  Year Built: 1965,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 225 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 223 (year 2032),  Design Load: HS 15,  Features Intersected: L. VERMILLION CR,  Facility Carried by Structure: MS 6490 IN MENDOTA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 507002,  Location: 10TH ST W OF 1ST AVE (Lat: 41.552422,  Lng: -89.109364),  Route carried "on" structure: City street ,  Year Built: 1947,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 100 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 223 (year 2032),  Features Intersected: FIRST CR,  Facility Carried by Structure: 10TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.547,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Channel: Good,  Culverts: Serious,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 507004,  Location: 100 FT N BURLINGTON (Lat: 41.551753,  Lng: -89.121333),  Route carried "on" structure: City street ,  Year Built: 1916,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 100 (year 2020),  Average Future Daily Traffic: 223 (year 2032),  Features Intersected: MENDOTA CR,  Facility Carried by Structure: MS6240 (INDIANA AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.386,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Fair,  Channel: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 507013,  Location: 100FT W OF ORCHARD (Lat: 41.541531,  Lng: -89.124281),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 225 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 223 (year 2032),  Design Load: HS 20,  Features Intersected: MENDOTA CREEK,  Facility Carried by Structure: 1ST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 507014,  Location: 10TH AVE & 4TH ST (Lat: 41.545147,  Lng: -89.122981),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 50 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 195 (year 2032),  Design Load: HS 20,  Features Intersected: MENDOTA CREEK,  Facility Carried by Structure: 10TH AVE & 4TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 507015,  Location: S EDGE MENDOTA (Lat: 41.543939,  Lng: -89.124097),  Route carried "on" structure: City street ,  Year Built: 2006,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 375 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 670 (year 2032),  Design Load: HS 20,  Features Intersected: MENDOTA CR,  Facility Carried by Structure: 3RD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.4m (17.7ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.8m (5.9ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 507016,  Location: 1st ave & 9th St. (Lat: 41.551675,  Lng: -89.108586),  Route carried "on" structure: Other road ,  Year Built: 2018,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 1,100 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 1,800 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: First Creek,  Facility Carried by Structure: FAU-6011 (1st Ave.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.207,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 55302,  Location: SW-35-T7NR2W (Lat: 40.547150,  Lng: -90.594481),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 275 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 461 (year 2032),  Design Load: HS 15,  Features Intersected: FARMERS FORK,  Facility Carried by Structure: FAS 1436-CH 12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 553036,  Location: NW-13-T6NR2W (Lat: 40.509389,  Lng: -90.578197),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 150 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 179 (year 2032),  Features Intersected: E FORK LAMOINE RIVER,  Facility Carried by Structure: FAS 1437 - CH 2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.545,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 553058,  Location: CTR-20-T6NR1W (Lat: 40.491719,  Lng: -90.535111),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 425 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 717 (year 2032),  Design Load: HS 20,  Features Intersected: KEPPLE CREEK,  Facility Carried by Structure: FAS 1437-CH 2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.776,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 554705,  Location: NE-22-T6NR2W (Lat: 40.498989,  Lng: -90.603431),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 75 (year 2021),  Average Future Daily Traffic: 77 (year 2032),  Design Load: HS 20,  Features Intersected: E FORK LAMOINE RIVER,  Facility Carried by Structure: TR 350
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.835,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 554712,  Location: E.CTR-2-T6NR2W (Lat: 40.536722,  Lng: -90.579711),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 25 (year 2016),  Average Future Daily Traffic: 26 (year 2032),  Design Load: HS 20,  Features Intersected: TOWN FORK,  Facility Carried by Structure: TR 368
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.676,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Fair,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 554713,  Location: N.CTR-12-T6NR2W (Lat: 40.528219,  Lng: -90.568931),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.88m (6.17ft),  Average Daily Traffic: 25 (year 2016),  Average Future Daily Traffic: 26 (year 2032),  Design Load: HS 20,  Features Intersected: FARMER'S FORK,  Facility Carried by Structure: TR 95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.901,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 554816,  Location: NE-20-T6NR1W (Lat: 40.494344,  Lng: -90.524108),  Route carried "on" structure: County highway ,  Year Built: 2007,  Status: Open,  Structure Length: 1.88m (6.17ft),  Average Daily Traffic: 75 (year 2021),  Truck Traffic: 36%,  Average Future Daily Traffic: 102 (year 2032),  Design Load: HS 20,  Features Intersected: KEPPLE CREEK,  Facility Carried by Structure: TR 406
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.327,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 554818,  Location: SWCOR-6-T6NR1W (Lat: 40.528689,  Lng: -90.559281),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 25 (year 2016),  Average Future Daily Traffic: 26 (year 2032),  Design Load: HS 20,  Features Intersected: E FORK OF LAMOINE RV,  Facility Carried by Structure: TR 95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.722,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 554819,  Location: W.CTR-7-T6NR1W (Lat: 40.520944,  Lng: -90.559644),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 154 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: TR 390
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.720,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 160214,  Location: S OF 63RD ST P10 (Lat: 41.776439,  Lng: -87.814378),  Route carried "under" structure: State highway 171,  Year Built: 1939,  Structure Length: 0. m,  Average Daily Traffic: 25,900 (year 2021),  Truck Traffic: 9%,  Features Intersected: ILL 171(ARCHER AV),  Facility Carried by Structure: B&OCT RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 37.400,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Length of Maximum Span: 15.5m (50.9ft)

Find on map >>   Show street view

Structure Number: 500016,  Location: 0.51 MI S OF US 34 (Lat: 41.540839,  Lng: -89.127419),  Route carried "under" structure: US 52,  Year Built: 1936,  Structure Length: 0. m,  Average Daily Traffic: 4,750 (year 2021),  Truck Traffic: 59%,  Features Intersected: US 52 & ILL 251,  Facility Carried by Structure: B. N. RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 127.119,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 500165,  Location: INTCHG US 34 & 1-39 (Lat: 41.554250,  Lng: -89.060819),  Route carried "under" structure: Interstate 39,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 20,200 (year 2019),  Truck Traffic: 38%,  Features Intersected: I-39/US 51,  Facility Carried by Structure: US 34 FAP 587
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 117.060,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.3m (106.0ft)

Discuss Bardolph, Illinois (IL) on our hugely popular Illinois forum.