Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Avondale, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 240ft / 72.8mTotal length
  • $4,840,000Total costs
  • 39,459Total average daily traffic
  • 3,422Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Avondale
  • No street view available for this location

New bridges in Avondale, CO - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 31930-1939
  • 11940-1949
  • 71950-1959
  • 11990-1999
  • 22000-2009
Reconstructed bridges in Avondale, CO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 01940-1949
  • 01950-1959
  • 01960-1969
  • 01970-1979
  • 11980-1989
Average Bridge Daily Traffic in Avondale, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Good
  • 27.3%Satisfactory
  • 27.3%Fair
  • 36.4%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 27.3%Good
  • 18.2%Satisfactory
  • 54.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 36.4%Good
  • 36.4%Satisfactory
  • 27.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 33.3%Good
  • 33.3%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Satisfactory
  • 66.7%Fair
Find on map >>   Show street view

Structure Number: K-19-Q,  Location: 4.7 MI E OF JCT SH 231 S (Lat: 38.265811,  Lng: -104.373011),  Route carried "on" structure: US 50B,  Year Built: 1953,  Status: Open,  Structure Length: 9.31m (30.54ft),  Average Daily Traffic: 4,300 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 4,902 (year 2040),  Design Load: HS 20,  Features Intersected: CHICO CREEK,  Facility Carried by Structure: US 50 ML WBND
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 21.533,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 79.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: K-19-R,  Location: 1.9 MI E OF JCT SH 229 S (Lat: 38.258892,  Lng: -104.334272),  Route carried "on" structure: State highway 96B,  Year Built: 1939,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 1,600 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,856 (year 2040),  Design Load: H 15,  Features Intersected: ARROYO,  Facility Carried by Structure: SH 96 ML
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 3.069,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: K-19-S,  Location: 2.7 MI E OF JCT SH 229 S (Lat: 38.256711,  Lng: -104.319356),  Route carried "on" structure: State highway 96B,  Year Built: 1939,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 1,600 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,856 (year 2040),  Design Load: H 20,  Features Intersected: ARROYO,  Facility Carried by Structure: SH 96 ML
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 4.394,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: K-19-U,  Location: 0.4 MI W OF JCT SH 96 E (Lat: 38.265644,  Lng: -104.373069),  Route carried "on" structure: US 50B,  Year Built: 1953,  Status: Open,  Structure Length: 9.31m (30.54ft),  Average Daily Traffic: 4,300 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 4,902 (year 2040),  Design Load: HS 20,  Features Intersected: CHICO CREEK,  Facility Carried by Structure: US 50 ML EBND
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 21.543,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 79.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: K-19-V,  Location: 5.0 MI E OF JCT SH 231 S (Lat: 38.262919,  Lng: -104.369753),  Route carried "on" structure: City street ,  Year Built: 1953,  Status: Open,  Structure Length: 6.97m (22.87ft),  Average Daily Traffic: 8,400 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 560 (year 2034),  Design Load: HS 20,  Features Intersected: US 50 ML,  Facility Carried by Structure: ORDINANCE ROAD
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 64.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-19-W,  Location: ROAD TO PUEBLO ARMY DEPOT (Lat: 38.265989,  Lng: -104.368717),  Route carried "on" structure: ServiceUS 50B,  Year Built: 1953,  Status: Open,  Structure Length: 7.71m (25.30ft),  Average Daily Traffic: 8,600 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 9,804 (year 2040),  Design Load: HS 20,  Features Intersected: BNSF RR AR,  Facility Carried by Structure: US 50 SERVICE RD
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.349,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.6m (67.6ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 28.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-19-X,  Location: 0.5 MI E OF JCT US 50 E (Lat: 38.263828,  Lng: -104.358742),  Route carried "on" structure: State highway 96B,  Year Built: 1939,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 1,700 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,938 (year 2040),  Design Load: H 20,  Features Intersected: DRAW,  Facility Carried by Structure: SH 96 ML
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.855,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: L-19-A,  Location: 3.5 Mi E/ SH 231 VINELAND (Lat: 38.244467,  Lng: -104.395847),  Route carried "on" structure: US 50C,  Year Built: 1942,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 2,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,080 (year 2040),  Design Load: H 20,  Features Intersected: SIX MILE CREEK,  Facility Carried by Structure: US 50 BUSINESS
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 20.666,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 43.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: L-19-F,  Location: JUST E. OF AVONDALE (Lat: 38.236483,  Lng: -104.339725),  Route carried "on" structure: US 50C,  Year Built: 1927,  Year Reconstructed: 1937,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 840 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 882 (year 2040),  Design Load: H 15,  Features Intersected: DRAW,  Facility Carried by Structure: US 50 BUS. RT
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 25.951,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 5.5m (18.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.96m (12.99ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $2,601,000,  Roadway Improvement Cost: $260,000,  Total Project Cost: $2,861,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: L-19-H,  Location: 1.7 MI E OF N. AVONDALE (Lat: 38.245275,  Lng: -104.344764),  Route carried "on" structure: US 50B,  Year Built: 1955,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 12.38m (40.62ft),  Average Daily Traffic: 4,100 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 4,387 (year 2040),  Design Load: HS 20,  Features Intersected: ARKANSAS RIVER,  Facility Carried by Structure: US 50 ML
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 24.903,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 77.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: PUCO 0.04-409A,  Location: 1.2 MI S OF SANTE FE DR (Lat: 38.226794,  Lng: -104.404575),  Route carried "on" structure: County highway ,  Year Built: 1950,  Status: Open,  Structure Length: 2.00m (6.56ft),  Average Daily Traffic: 105 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 148 (year 2038),  Features Intersected: SIX MILE CREEK,  Facility Carried by Structure: Co RD 42/42nd LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.610,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 7.1m (23.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 34.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.80m (9.19ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Critical Feature Inspection Date: November 2020,  Bridge Improvement Cost: $1,583,000,  Roadway Improvement Cost: $158,000,  Total Project Cost: $1,979,000 ( Estimate for 2018),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: PUCO 0.06-303ER,  Location: 0.5 MI S OF OLSON RD (Lat: 38.206083,  Lng: -104.349200),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 199 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 280 (year 2038),  Design Load: HS 20,  Features Intersected: BESSEMER DITCH,  Facility Carried by Structure: CO RD 327/AVONDALE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.794,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.9m (29.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 71.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: PUCO 0.24-404AR,  Location: 0.24 MI S OF SH 50 (Lat: 38.248167,  Lng: -104.398956),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 132 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 186 (year 2038),  Design Load: HL 93,  Features Intersected: ARKANSAS RIVER,  Facility Carried by Structure: CR 442 (NYBERG RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.375,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.5m (126.3ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: PUCO 0.42-409BR,  Location: 0.3 MI S OF SH 50 (Lat: 38.242044,  Lng: -104.349103),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 8.88m (29.13ft),  Average Daily Traffic: 1,203 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,696 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: ARKANSAS RIVER,  Facility Carried by Structure: CR 327 (AVONDALE)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 42.4m (139.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: K-19-V,  Location: 5.0 MI E OF JCT SH 231 S (Lat: 38.262919,  Lng: -104.369753),  Route carried "under" structure: US 50B,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 380 (year 2018),  Truck Traffic: 12%,  Features Intersected: US 50 ML,  Facility Carried by Structure: ORDINANCE ROAD
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Discuss Avondale, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.