Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Arroyo Grande, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 27Number of bridges
  • 236ft / 72.2mTotal length
  • 357,894Total average daily traffic
  • 28,290Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Arroyo Grande
  • No street view available for this location

New bridges in Arroyo Grande, CA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21920-1929
  • 31930-1939
  • 121950-1959
  • 31960-1969
  • 11970-1979
  • 21980-1989
  • 11990-1999
  • 12010-2019
  • 12020-2022
Reconstructed bridges in Arroyo Grande, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 11940-1949
Average Bridge Daily Traffic in Arroyo Grande, CA
Average Bridge Truck Traffic in Arroyo Grande, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Good
  • 20.0%Satisfactory
  • 30.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 71.4%Good
  • 4.8%Satisfactory
  • 23.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Good
  • 9.5%Satisfactory
  • 23.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 5.6%Excellent
  • 16.7%Very good
  • 44.4%Good
  • 16.7%Satisfactory
  • 5.6%Poor
  • 11.1%Serious
Find on map >>   Show street view

Structure Number: 49 0022,  Location: 05-SLO-001-10.35 (Lat: 35.097881,  Lng: -120.581631),  Route carried "on" structure: State highway 1,  Year Built: 1952,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 6,200 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,860 (year 2039),  Design Load: HS 20,  Features Intersected: LOS BERROS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.350,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49 011,  Location: 05-SLO-227-1.43-ARGD (Lat: 35.134206,  Lng: -120.570103),  Route carried "on" structure: State highway 227,  Year Built: 1914,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 3,350 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,081 (year 2042),  Features Intersected: CORBETT CANYON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.430,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.7m (28.5ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 38.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49 0151L,  Location: 05-SLO-101-45.72-ATAS (Lat: 35.486447,  Lng: -120.667222),  Route carried "on" structure: US 101,  Year Built: 1956,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 30,000 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 36,639 (year 2043),  Design Load: HS 20,  Features Intersected: ATASCADERO CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.720,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 16.9m (55.4ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Channel: Very good,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49 0154,  Location: 05-SLO-101-13.75-ARGD (Lat: 35.124319,  Lng: -120.593014),  Route carried "on" structure: US 101,  Year Built: 1956,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 56,000 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 105,161 (year 2044),  Design Load: HS 20,  Features Intersected: BRISCO RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.750,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 31.7m (104.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 31.7m (104.0ft),  Out-to-Out Width: 32.6m (107.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 49 017,  Location: 05-SLO-058-R29.92 (Lat: 35.425383,  Lng: -120.226592),  Route carried "on" structure: State highway 58,  Year Built: 1984,  Status: Open,  Structure Length: 2.39m (7.84ft),  Average Daily Traffic: 495 (year 2009),  Truck Traffic: 17%,  Average Future Daily Traffic: 1,392 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: NAVAJO CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.920,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49 0173R,  Location: 05-SLO-101-12.52-ARGD (Lat: 35.116736,  Lng: -120.573842),  Route carried "on" structure: US 101,  Year Built: 1959,  Status: Open,  Structure Length: 6.67m (21.88ft),  Average Daily Traffic: 25,500 (year 2009),  Truck Traffic: 8%,  Average Future Daily Traffic: 51,674 (year 2044),  Design Load: HS 20,  Features Intersected: BRIDGE ST-S101 ON RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.520,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Other Special Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 49 0174,  Location: 05-SLO-101-12.80-ARGD (Lat: 35.118808,  Lng: -120.578011),  Route carried "on" structure: City street Z881,  Year Built: 1959,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 7,000 (year 2009),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,532 (year 2044),  Design Load: HS 20,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: FAIR OAKS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 84.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 49 0175L,  Location: 05-SLO-101-13.02-ARGD (Lat: 35.120511,  Lng: -120.581133),  Route carried "on" structure: US 101,  Year Built: 1959,  Status: Open,  Structure Length: 5.24m (17.19ft),  Average Daily Traffic: 24,000 (year 2012),  Truck Traffic: 9%,  Average Future Daily Traffic: 47,751 (year 2044),  Design Load: HS 20,  Features Intersected: ARROYO GRANDE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.020,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49 0175R,  Location: 05-SLO-101-13.02-ARGD (Lat: 35.120692,  Lng: -120.581033),  Route carried "on" structure: US 101,  Year Built: 1959,  Status: Open,  Structure Length: 5.24m (17.19ft),  Average Daily Traffic: 24,000 (year 2012),  Truck Traffic: 8%,  Average Future Daily Traffic: 44,805 (year 2044),  Design Load: HS 20,  Features Intersected: ARROYO GRANDE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.020,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Serious,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49 0176,  Location: 05-SLO-101-13.17-ARGD (Lat: 35.121247,  Lng: -120.583833),  Route carried "on" structure: City street ,  Year Built: 1959,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 16,200 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,661 (year 2044),  Design Load: HS 20,  Features Intersected: US HWY 101 (@PM 13.17),  Facility Carried by Structure: GRAND AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.0m (65.6ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0119,  Location: 6.9 MI N OF SR 101 (Lat: 35.173089,  Lng: -120.528358),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Posted for load,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 100 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 81 (year 2041),  Features Intersected: ARROYO GRANDE CREEK,  Facility Carried by Structure: GREIB RANCH WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 5.8m (19.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 12.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 5.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0124,  Location: 0.04 MI SE LOPEZ DR (Lat: 35.139233,  Lng: -120.546972),  Route carried "on" structure: County highway ,  Year Built: 1923,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 966 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,164 (year 2041),  Features Intersected: ARROYO GRANDE CREEK,  Facility Carried by Structure: HUASNA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Serious,  Operating Rating: 26.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49C0191,  Location: 2.4 MI E SANTA MARG RD (Lat: 35.349472,  Lng: -120.502103),  Route carried "on" structure: County highway ,  Year Built: 1930,  Year Reconstructed: 1954,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 189 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 575 (year 2040),  Design Load: H 10,  Features Intersected: PILITAS CREEK,  Facility Carried by Structure: LAS PILITAS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.9m (19.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49C0196,  Location: 0.1 MI S OF STATE RTE 227 (Lat: 35.122361,  Lng: -120.578472),  Route carried "on" structure: City street ,  Year Built: 2021,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 4,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,200 (year 2041),  Design Load: HL 93,  Features Intersected: ARROYO GRANDE CREEK,  Facility Carried by Structure: BRIDGE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 30.9m (101.4ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0201,  Location: 0.1 MI S OF SR 227 (Lat: 35.123722,  Lng: -120.576056),  Route carried "on" structure: City street ,  Year Built: 1926,  Status: Open,  Structure Length: 5.12m (16.80ft),  Average Daily Traffic: 5,546 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,993 (year 2038),  Design Load: HS 20,  Features Intersected: ARROYO GRANDE CREEK,  Facility Carried by Structure: MASON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Operating Rating: 29.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49C031,  Location: AT ASUNCION RD (Lat: 35.428617,  Lng: -120.605603),  Route carried "on" structure: County highway ,  Year Built: 1930,  Year Reconstructed: 1937,  Status: Open,  Structure Length: 2.47m (8.10ft),  Average Daily Traffic: 5,046 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,832 (year 2040),  Design Load: H 15,  Features Intersected: SANTA MARGARITA CREEK,  Facility Carried by Structure: EL CAMINO REAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.2m (33.5ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 4.9m (16.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Critical Feature Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49C0318,  Location: ARROYO GRANDE (Lat: 35.122186,  Lng: -120.580522),  Route carried "on" structure: City street ,  Year Built: 1932,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 9,600 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,304 (year 2040),  Design Load: H 15,  Features Intersected: ARROYO GRANDE CREEK,  Facility Carried by Structure: TRAFFIC WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0352,  Location: 0.4 MI N SR 1 (Lat: 35.103494,  Lng: -120.581492),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 5,167 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,728 (year 2040),  Design Load: H 20,  Features Intersected: LOS BERROS CRK DIV CHNL,  Facility Carried by Structure: VALLEY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 41.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C04,  Location: ARROYO GRANDE (Lat: 35.112633,  Lng: -120.587828),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 8,945 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,461 (year 2040),  Features Intersected: ARROYO GRANDE CREEK,  Facility Carried by Structure: FAIR OAKS BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.3m (99.4ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0425,  Location: JEO LOS BANOS RD (Lat: 35.102947,  Lng: -120.578661),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 2.00m (6.56ft),  Average Daily Traffic: 250 (year 2001),  Truck Traffic: 1%,  Average Future Daily Traffic: 312 (year 2036),  Features Intersected: LOS BERROS CREEK,  Facility Carried by Structure: CENTURY LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.5m (31.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2018
Find on map >>   Show street view

Structure Number: 49C0459,  Location: 0.2 MI S OF HUASNA ROAD (Lat: 35.131722,  Lng: -120.542806),  Route carried "on" structure: County highway ,  Year Built: 2015,  Status: Open,  Structure Length: 3.27m (10.73ft),  Average Daily Traffic: 1,240 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,500 (year 2039),  Design Load: HL 93,  Features Intersected: TAR SPRING CREEK,  Facility Carried by Structure: BRANCH MILL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.3m (99.4ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C046,  Location: JEO ALYSSUM CT (Lat: 35.248239,  Lng: -120.639050),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 1,100 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,000 (year 2041),  Features Intersected: E FK SAN LUIS OBISPO CRK,  Facility Carried by Structure: POINSETTIA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.5m (24.6ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 49 0154,  Location: 05-SLO-101-13.75-ARGD (Lat: 35.124319,  Lng: -120.593014),  Route carried "under" structure: ServiceCity street ,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2009),  Truck Traffic: 8%,  Features Intersected: BRISCO RD,  Facility Carried by Structure: U.S. HIGHWAY 101
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Frame,  Length of Maximum Span: 12.2m (40.0ft)

Find on map >>   Show street view

Structure Number: 49 0173R,  Location: 05-SLO-101-12.52-ARGD (Lat: 35.116736,  Lng: -120.573842),  Route carried "under" structure: Ramp US 101,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 2,800 (year 2014),  Truck Traffic: 10%,  Features Intersected: BRIDGE ST-S101 ON RAMP
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 12.520,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 49 0174,  Location: 05-SLO-101-12.80-ARGD (Lat: 35.118808,  Lng: -120.578011),  Route carried "under" structure: US 101,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 48,000 (year 2009),  Truck Traffic: 9%,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: FAIR OAKS AVE
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 12.800,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 18.9m (62.0ft)

Find on map >>   Show street view

Structure Number: 49 0176,  Location: 05-SLO-101-13.17-ARGD (Lat: 35.121247,  Lng: -120.583833),  Route carried "under" structure: US 101,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 48,000 (year 2009),  Truck Traffic: 9%,  Features Intersected: US HWY 101 (@PM 13.17),  Facility Carried by Structure: GRAND AVE
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 13.170,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 49C0469,  Location: .06 MI SW OF HUASNA RD (Lat: 35.126564,  Lng: -120.570575),  Route carried "under" structure: State highway 227,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 16,200 (year 2006),  Truck Traffic: 6%,  Features Intersected: STATE ROUTE 227,  Facility Carried by Structure: PEDESTRIAN WALKWAY
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.870,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Discuss Arroyo Grande, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.