Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Altona, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 108ft / 32.7mTotal length
  • 22,560Total average daily traffic
  • 7,272Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Altona
  • No street view available for this location

New bridges in Altona, IL - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 11920-1929
  • 11930-1939
  • 31960-1969
  • 21980-1989
  • 31990-1999
  • 32010-2019
Reconstructed bridges in Altona, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 11980-1989
Average Bridge Daily Traffic in Altona, IL
Average Bridge Truck Traffic in Altona, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 36.4%Very good
  • 18.2%Good
  • 18.2%Satisfactory
  • 18.2%Fair
  • 9.1%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 36.4%Very good
  • 18.2%Good
  • 18.2%Satisfactory
  • 18.2%Fair
  • 9.1%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 45.5%Very good
  • 18.2%Good
  • 18.2%Satisfactory
  • 18.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.7%Excellent
  • 15.4%Very good
  • 15.4%Good
  • 61.5%Satisfactory
Find on map >>   Show street view

Structure Number: 380135,  Location: CLIFTON INTER (Lat: 40.928839,  Lng: -87.928719),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Open,  Structure Length: 7.99m (26.21ft),  Average Daily Traffic: 900 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 1,565 (year 2032),  Design Load: HS 20,  Features Intersected: I-57,  Facility Carried by Structure: FAS 321 (CH 4)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.604,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 480038,  Location: 1 MI SW OF ALTONA (Lat: 41.107681,  Lng: -90.171317),  Route carried "on" structure: US 34,  Year Built: 1921,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 2,200 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 2,505 (year 2032),  Design Load: HS 20,  Features Intersected: WALNUT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 97.137,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Other Special Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 483131,  Location: N1/2-17-T13NR3E (Lat: 41.119158,  Lng: -90.183392),  Route carried "on" structure: County highway ,  Year Built: 1900,  Year Reconstructed: 1973,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 50 (year 2017),  Average Future Daily Traffic: 50 (year 2032),  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: TR 210
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.621,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 37.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 483142,  Location: NE-22-T13NR3E (Lat: 41.101667,  Lng: -90.135197),  Route carried "on" structure: County highway ,  Year Built: 1966,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 50 (year 2017),  Average Future Daily Traffic: 50 (year 2032),  Design Load: HS 15,  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: TR 244
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.456,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: March 2021,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 483237,  Location: NW-21-T13NR3E (Lat: 41.105375,  Lng: -90.174128),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 50 (year 2017),  Average Future Daily Traffic: 50 (year 2032),  Design Load: HS 20,  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: TR 39
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.412,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 483274,  Location: NE-14-T13NR3E (Lat: 41.118581,  Lng: -90.115911),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 25 (year 2017),  Average Future Daily Traffic: 25 (year 2032),  Design Load: HS 20,  Features Intersected: MUD RUN CREEK,  Facility Carried by Structure: TR 254
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.044,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 483307,  Location: NE-21-T13NR3E (Lat: 41.104253,  Lng: -90.161925),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 3.67m (12.04ft),  Average Daily Traffic: 275 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 276 (year 2032),  Design Load: HS 20,  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: FAS 394-CH 12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.127,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 483347,  Location: E.CTR-14-T13NR3E (Lat: 41.113850,  Lng: -90.121353),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 1.85m (6.07ft),  Average Daily Traffic: 450 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 651 (year 2032),  Design Load: HS 20,  Features Intersected: MUD RUN CREEK,  Facility Carried by Structure: FAS 393-CH 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.060,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 483371,  Location: CTR-9-T13NR3E (Lat: 41.129153,  Lng: -90.161483),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 75 (year 2017),  Average Future Daily Traffic: 75 (year 2032),  Design Load: HS 20,  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: TR 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.460,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 483393,  Location: E.CTR-17-T13NR3E (Lat: 41.114714,  Lng: -90.176208),  Route carried "on" structure: County highway ,  Year Built: 2019,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 300 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 333 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: FAS 393 - CH 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.442,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 483403,  Location: NE-23-T13NR3E (Lat: 41.106550,  Lng: -90.131139),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 10 (year 2017),  Average Future Daily Traffic: 25 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: Mud Run Creek,  Facility Carried by Structure: TR 29
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 485011,  Location: CTR-17-T13NR3E (Lat: 41.114869,  Lng: -90.185767),  Route carried "on" structure: County highway ,  Year Built: 1934,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 300 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 301 (year 2032),  Features Intersected: WALNUT CREEK,  Facility Carried by Structure: FAS 393-CH 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.637,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 485013,  Location: SW-7-T13NR3E (Lat: 41.125500,  Lng: -90.202689),  Route carried "on" structure: County highway ,  Year Built: 1900,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 25 (year 2017),  Average Future Daily Traffic: 25 (year 2032),  Features Intersected: WALNUT CR,  Facility Carried by Structure: TR 192
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.945,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 485037,  Location: E.CTR-16-T13NR3E (Lat: 41.114278,  Lng: -90.154453),  Route carried "on" structure: County highway ,  Year Built: 2015,  Status: Open,  Structure Length: 1.11m (3.64ft),  Average Daily Traffic: 450 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 870 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: Walnut Creek Trib,  Facility Carried by Structure: Main St / FAS 393
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.276,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 380135,  Location: CLIFTON INTER (Lat: 40.928839,  Lng: -87.928719),  Route carried "under" structure: Interstate 57,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 17,400 (year 2021),  Truck Traffic: 39%,  Features Intersected: I-57,  Facility Carried by Structure: FAS 321 (CH 4)
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 477.399,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)