Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Algonac, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 135ft / 40.8mTotal length
  • $342,000Total costs
  • 58,651Total average daily traffic
  • 4,183Total average daily truck traffic
  • 94,229Total future (year 2010) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Algonac
  • No street view available for this location

New bridges in Algonac, MI - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 21950-1959
  • 41970-1979
  • 31980-1989
  • 21990-1999
  • 32010-2019
Reconstructed bridges in Algonac, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21990-1999
  • 02000-2009
  • 22010-2019
Average Bridge Daily Traffic in Algonac, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 25.0%Good
  • 37.5%Satisfactory
  • 12.5%Fair
  • 12.5%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 41.7%Good
  • 25.0%Satisfactory
  • 8.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 16.7%Very good
  • 33.3%Good
  • 41.7%Satisfactory
  • 8.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 18.8%Very good
  • 37.5%Good
  • 31.3%Satisfactory
  • 12.5%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 50.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 997,  Location: 2.5 MI S E OF SODUS (Lat: 42.035108,  Lng: -86.328244),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 268 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 500 (year 2027),  Design Load: HS 20,  Features Intersected: PIPESTONE CREEK,  Facility Carried by Structure: PARK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.385,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1025,  Location: 5.5 MI E OF SODUS (Lat: 42.049503,  Lng: -86.281008),  Route carried "on" structure: County highway ,  Year Built: 1924,  Status: Posted for load,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 4 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 10 (year 2027),  Design Load: H 15,  Features Intersected: PIPESTONE CREEK,  Facility Carried by Structure: BAILEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.160,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 4.6m (15.1ft),  Out-to-Out Width: 4.8m (15.7ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Poor,  Channel: Fair,  Operating Rating: 3.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 2.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of replacement,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.68m (5.51ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $250,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $300,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 386,  Location: 2 MI NW OF ONONDAGA (Lat: 42.465678,  Lng: -84.568028),  Route carried "on" structure: County highway ,  Year Built: 1952,  Status: Posted for load,  Structure Length: 4.14m (13.58ft),  Average Daily Traffic: 1,230 (year 2019),  Average Future Daily Traffic: 1,510 (year 2039),  Design Load: H 20,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: KINNEVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.686,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 23.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 14.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 4.14m (13.58ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2021,  Underwater Inspection Date: October 2021,  Bridge Improvement Cost: $11,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $32,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 6218,  Location: 2.5MI W OF GRATIOT US-25 (Lat: 42.718364,  Lng: -82.847797),  Route carried "on" structure: County highway 5060,  Year Built: 2012,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 11,617 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,175 (year 2031),  Design Load: Greater than HL93,  Features Intersected: DEER CREEK,  Facility Carried by Structure: 26 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.002,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 81,  Subroute: 2),  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6219,  Location: 0.5MI EAST OF GRATIOT AVE (Lat: 42.719561,  Lng: -82.785608),  Route carried "on" structure: County highway 5060,  Year Built: 1996,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 8,910 (year 2008),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,600 (year 2028),  Design Load: HS 25 or greater,  Features Intersected: SALT RIVER,  Facility Carried by Structure: 26 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 25.095,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 622,  Location: 1.3 MI E OF NEW HAVEN RD (Lat: 42.719961,  Lng: -82.767983),  Route carried "on" structure: County highway 5060,  Year Built: 2010,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 10,465 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 18,900 (year 2030),  Design Load: Greater than HL93,  Features Intersected: KIRKHAM DRAIN,  Facility Carried by Structure: 26 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 26.541,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 50.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 6221,  Location: 1.7 MI E OF NEW HAVEN RD (Lat: 42.720122,  Lng: -82.759469),  Route carried "on" structure: County highway 5060,  Year Built: 2010,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 10,465 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 18,900 (year 2030),  Design Load: Greater than HL93,  Features Intersected: BRANCH OF KIRKHAM DRAIN,  Facility Carried by Structure: 26 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 27.237,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 9673,  Location: IN MANISTIQUE (Lat: 45.953733,  Lng: -86.249308),  Route carried "on" structure: US 2,  Year Built: 1983,  Status: Open,  Structure Length: 20.73m (68.01ft),  Average Daily Traffic: 4,300 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 8,657 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: MANISTIQUE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.300,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 119,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 15.4m (50.5ft),  Skew: 9 degrees,  Navigation Control: Yes ( Vertical Clearance: 0.3m (1.0ft), Horizontal Clearance: 48.7m (159.8ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 48.8m (160.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 17.6m (57.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 75.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 997,  Location: IN ALGONAC (Lat: 42.626272,  Lng: -82.523911),  Route carried "on" structure: State highway 29,  Year Built: 1952,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 5,939 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,895 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: COX'S DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.777,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 450,  Subroute: 33),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.4m (24.3ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9971,  Location: IN ALGONAC (Lat: 42.630564,  Lng: -82.517219),  Route carried "on" structure: State highway 29,  Year Built: 1942,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 3,717 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,932 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: MARINE CITY DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.526,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 450,  Subroute: 33),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10156,  Location: PC 191-318 COTTRELLVILLE (Lat: 42.664008,  Lng: -82.529436),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 450 (year 1994),  Truck Traffic: 3%,  Average Future Daily Traffic: 550 (year 2014),  Design Load: HS 20+Mod,  Features Intersected: MARINE CITY DREDGE CUT,  Facility Carried by Structure: ROBERTS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.508,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.29m (7.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Roadway Improvement Cost: $9,000,  Total Project Cost: $10,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 10247,  Location: N E OF WILLARD INTERSECT (Lat: 42.611553,  Lng: -82.539417),  Route carried "on" structure: ServiceCity street ,  Year Built: 1978,  Year Reconstructed: 2010,  Status: Posted for load,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 250 (year 1993),  Truck Traffic: 3%,  Average Future Daily Traffic: 300 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: OREOLE CANAL,  Facility Carried by Structure: RUSKIN AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.356,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 10248,  Location: N OF RUSKIN INTERSECTION (Lat: 42.611556,  Lng: -82.536203),  Route carried "on" structure: ServiceCity street ,  Year Built: 1999,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 628 (year 1993),  Truck Traffic: 3%,  Average Future Daily Traffic: 750 (year 2010),  Design Load: HS 20,  Features Intersected: BATTEAUX CANAL,  Facility Carried by Structure: EDGEWATER DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.412,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.7m (38.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 10249,  Location: .1MI E OF ST CLAIR RIV DR (Lat: 42.624781,  Lng: -82.524992),  Route carried "on" structure: ServiceCity street ,  Year Built: 1977,  Year Reconstructed: 2010,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 66 (year 1993),  Average Future Daily Traffic: 100 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: CANAL PARALLEL TO M29,  Facility Carried by Structure: VENETIAN WAY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.050,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1025,  Location: .1MI E OF ST CLAIR RIV DR (Lat: 42.625694,  Lng: -82.523908),  Route carried "on" structure: ServiceCity street ,  Year Built: 1979,  Status: Posted for load,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 108 (year 1993),  Truck Traffic: 3%,  Average Future Daily Traffic: 150 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: CANAL PARALLEL TO M 29,  Facility Carried by Structure: CHANNELSYDE DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.056,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.8m (15.7ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 76.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10251,  Location: .1MI E OF ST CLAIR RIV DR (Lat: 42.626333,  Lng: -82.522497),  Route carried "on" structure: ServiceCity street ,  Year Built: 1979,  Status: Posted for load,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 234 (year 1993),  Truck Traffic: 3%,  Average Future Daily Traffic: 300 (year 2010),  Design Load: HS 20,  Features Intersected: CANAL PARALLEL TO M 29,  Facility Carried by Structure: ROSELAWN COURT
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.055,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous