Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Akron, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 46ft / 14.2mTotal length
  • $290,000Total costs
  • 8,195Total average daily traffic
  • 326Total average daily truck traffic
  • 12,116Total future (year 2018) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Akron
  • No street view available for this location

New bridges in Akron, MI - historical statistics
  • New bridges - historical statistics
  • 31960-1969
  • 41970-1979
  • 21980-1989
  • 11990-1999
  • 12000-2009
  • 32010-2019
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 22.2%Very good
  • 44.4%Good
  • 22.2%Satisfactory
  • 11.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 22.2%Very good
  • 44.4%Good
  • 11.1%Satisfactory
  • 22.2%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 22.2%Very good
  • 55.6%Good
  • 11.1%Satisfactory
  • 11.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.1%Very good
  • 42.9%Good
  • 28.6%Satisfactory
  • 21.4%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 40.0%Very good
  • 40.0%Good
  • 20.0%Satisfactory
Find on map >>   Show street view

Structure Number: 104,  Location: W LTS OF AKRON (Lat: 43.566258,  Lng: -83.523314),  Route carried "on" structure: State highway 138,  Year Built: 1968,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,678 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,642 (year 2018),  Design Load: HS 20,  Features Intersected: ALLEN DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.886,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 27,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 10401,  Location: 4.5 MI S OF M-25 (Lat: 43.590319,  Lng: -83.465056),  Route carried "on" structure: State highway 138,  Year Built: 1983,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 1,825 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,004 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: WISCOGGIN CREEK,  Facility Carried by Structure: M-24
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.807,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 27,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.2m (33.5ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 10474,  Location: SEC 6-7 ALMER TWP (Lat: 43.567203,  Lng: -83.453822),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 430 (year 2009),  Average Future Daily Traffic: 780 (year 2029),  Design Load: HS 20,  Features Intersected: WISCOGGIN DRAIN,  Facility Carried by Structure: AKRON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.502,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.7m (28.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 90.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 54.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10477,  Location: SEC 17-20 AKRON TWP (Lat: 43.609275,  Lng: -83.564761),  Route carried "on" structure: County highway 7986,  Year Built: 1971,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 1,300 (year 2009),  Average Future Daily Traffic: 2,350 (year 2029),  Design Load: HS 20,  Features Intersected: ALLEN DRAIN,  Facility Carried by Structure: DICKERSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.979,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.4m (27.6ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10478,  Location: SEC 17-20 AKRON TWP (Lat: 43.609397,  Lng: -83.554894),  Route carried "on" structure: County highway 7986,  Year Built: 2009,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 1,300 (year 2009),  Average Future Daily Traffic: 2,350 (year 2029),  Design Load: HS 20,  Features Intersected: LATIMER OR ALLEN RELIEF,  Facility Carried by Structure: DICKERSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.776,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 38.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10536,  Location: SEC 29-32 AKRON TWP (Lat: 43.580325,  Lng: -83.563858),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1992,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 225 (year 2009),  Average Future Daily Traffic: 410 (year 2029),  Design Load: HS 20,  Features Intersected: ALLEN DRAIN,  Facility Carried by Structure: ELMWOOD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.441,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 10539,  Location: SEC 20-29 AKRON TWP (Lat: 43.594900,  Lng: -83.554500),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 2016,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 72 (year 2009),  Average Future Daily Traffic: 130 (year 2029),  Design Load: H 15,  Features Intersected: LATIMER OR ALLEN RELIEF,  Facility Carried by Structure: CASS CITY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.371,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 94.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.34m (4.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $248,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $290,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1054,  Location: SEC 24-25 AKRON TWP (Lat: 43.595819,  Lng: -83.470581),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1984,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 78 (year 2009),  Average Future Daily Traffic: 140 (year 2029),  Design Load: HS 20,  Features Intersected: WISCOGGIN DRAIN,  Facility Carried by Structure: CASS CITY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.337,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.9m (32.5ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10543,  Location: SEC 32-33 AKRON TWP (Lat: 43.576264,  Lng: -83.544211),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 2014,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 175 (year 2014),  Truck Traffic: 3%,  Average Future Daily Traffic: 315 (year 2034),  Design Load: Greater than HL93,  Features Intersected: ALLEN EXT DRAIN,  Facility Carried by Structure: THOMAS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.266,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 42.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10544,  Location: SEC 18-19 ALMER TWP (Lat: 43.538136,  Lng: -83.457275),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1979,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 60 (year 2009),  Average Future Daily Traffic: 110 (year 2029),  Design Load: H 20,  Features Intersected: WISCOGGIN DRAIN,  Facility Carried by Structure: DARBEE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.548,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 10545,  Location: SEC 7-18 ALMER TWP (Lat: 43.552736,  Lng: -83.451311),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1979,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 70 (year 2009),  Average Future Daily Traffic: 120 (year 2029),  Design Load: H 20,  Features Intersected: WISCOGGIN DRAIN,  Facility Carried by Structure: DUTCHER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.031,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.5m (14.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 10554,  Location: SEC 31 COLUMBIA TWP (Lat: 43.581256,  Lng: -83.457350),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 2013,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 202 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 365 (year 2032),  Design Load: Greater than HL93,  Features Intersected: WISCOGGIN DRAIN,  Facility Carried by Structure: ELMWOOD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 17.047,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10587,  Location: SEC 3-4 FAIRGROVE TWP (Lat: 43.564908,  Lng: -83.524356),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1964,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 390 (year 2009),  Average Future Daily Traffic: 700 (year 2029),  Design Load: H 20,  Features Intersected: ALLEN EXTN DRAIN,  Facility Carried by Structure: RINGLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.015,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10588,  Location: SEC 3-4 FAIRGROVE TWP (Lat: 43.560700,  Lng: -83.524286),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1965,  Status: Open,  Structure Length: 0.92m (3.02ft),  Average Daily Traffic: 390 (year 2009),  Average Future Daily Traffic: 700 (year 2029),  Design Load: H 20,  Features Intersected: ALLEN EXTN DRAIN,  Facility Carried by Structure: RINGLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.548,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 50.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Discuss Akron, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.