Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Milton, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 210ft / 63.7mTotal length
  • 165,500Total average daily traffic
  • 12,254Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Milton
  • No street view available for this location

New bridges in Milton, FL - historical statistics
  • New bridges - historical statistics
  • 31950-1959
  • 11960-1969
  • 11970-1979
  • 11980-1989
  • 11990-1999
  • 22000-2009
  • 32010-2019
Average Bridge Daily Traffic in Milton, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.1%Very good
  • 66.7%Good
  • 22.2%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Very good
  • 44.4%Good
  • 11.1%Satisfactory
  • 11.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 22.2%Very good
  • 22.2%Good
  • 22.2%Satisfactory
  • 22.2%Fair
  • 11.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 22.2%Very good
  • 55.6%Good
  • 22.2%Satisfactory
Find on map >>   Show street view

Structure Number: 580011,  Location: 1.0mi West of SR89 (Lat: 30.607628,  Lng: -87.061853),  Route carried "on" structure: US 90,  Year Built: 1950,  Status: Open,  Structure Length: 11.09m (36.38ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 29,495 (year 2042),  Design Load: HS 20,  Features Intersected: Pond Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.216,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Underwater Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 58003,  Location: 0.75Mi North of I-10W (Lat: 30.602108,  Lng: -87.007608),  Route carried "on" structure: County highway 89,  Year Built: 1950,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 4,600 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 7,981 (year 2042),  Design Load: HS 20,  Features Intersected: Pelican Bayou
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.080,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 4.6m (15.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 58005,  Location: 0.9mi. North of US90 (Lat: 30.628528,  Lng: -87.056194),  Route carried "on" structure: State highway 89,  Year Built: 1963,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 18,100 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 31,404 (year 2042),  Design Load: HS 20,  Features Intersected: Branch
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.427,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 12 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 2.5m (8.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 580066,  Location: 1.0mi West of SR89 (Lat: 30.607533,  Lng: -87.061769),  Route carried "on" structure: US 90,  Year Built: 1958,  Status: Open,  Structure Length: 11.09m (36.38ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 29,495 (year 2042),  Design Load: H 20,  Features Intersected: Pond Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.216,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 43.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Underwater Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 580093,  Location: 0.3mi North of US90 SR10 (Lat: 30.626472,  Lng: -87.043167),  Route carried "on" structure: State highway 87,  Year Built: 1976,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 29,495 (year 2042),  Design Load: HS 20,  Features Intersected: Wright Basin
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.531,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 580098,  Location: 0.5 Miles East Of SR87 (Lat: 30.623906,  Lng: -87.035158),  Route carried "on" structure: US 90,  Year Built: 1986,  Status: Open,  Structure Length: 18.29m (60.01ft),  Average Daily Traffic: 21,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 37,302 (year 2042),  Design Load: HS 20,  Features Intersected: Blackwater River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.500,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Number Of Approach Spans: 15,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Underwater Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580175,  Location: 1.4 Miles East of SR87N (Lat: 30.625997,  Lng: -87.022856),  Route carried "on" structure: US 90,  Year Built: 2003,  Status: Open,  Structure Length: 4.90m (16.08ft),  Average Daily Traffic: 21,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 37,302 (year 2042),  Design Load: HS 15,  Features Intersected: FG&A RR & Old Spanish Tr
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.986,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 24 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.5m (80.4ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 22.8m (74.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 67.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580186,  Location: 0.84Mi North WB I10 (Lat: 30.569444,  Lng: -87.086944),  Route carried "on" structure: State highway 281,  Year Built: 2014,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 24,500 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,508 (year 2042),  Design Load: HL 93,  Features Intersected: FG&A RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.025,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 29.3m (96.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580209,  Location: 0.5Mi E of CR191 (Lat: 30.627806,  Lng: -87.029500),  Route carried "on" structure: US 90,  Year Built: 2015,  Status: Open,  Structure Length: 9.02m (29.59ft),  Average Daily Traffic: 21,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 37,302 (year 2042),  Design Load: HL 93,  Features Intersected: Marquis Bayou
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.278,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 17.6m (57.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 584238,  Location: 0.11Mi N of Berryhill Rd. (Lat: 30.625750,  Lng: -87.037472),  Route carried "on" structure: City street 191,  Year Built: 2019,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 2,100 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,644 (year 2042),  Features Intersected: Collins Mill Creek,  Facility Carried by Structure: Broad Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.314,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Inventory Rating: 80.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Underwater Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 585001,  Location: 0.08 Mi N of Berryhill St (Lat: 30.625806,  Lng: -87.038306),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Posted for load,  Structure Length: 1.30m (4.27ft),  Average Daily Traffic: 500 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 868 (year 2042),  Features Intersected: Collins Creek,  Facility Carried by Structure: Conecuh Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.140,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.5m (14.8ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 23.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: June 2020,  Other Special Inspection Date: June 2021,  Deck Structure Type: Wood or Timber
Find on map >>   Show street view

Structure Number: 580175,  Location: 1.4 Miles East of SR87N (Lat: 30.625997,  Lng: -87.022856),  Route carried "under" structure: City street ,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 200 (year 2004),  Truck Traffic: 1%,  Features Intersected: FG&A RR & Old Spanish Tr,  Facility Carried by Structure: US90 SR10
Minimum Vertical Clearance: 5.52m (18.11ft),  Kilometerpoint: 0.002,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.5m (80.4ft)

Discuss Milton, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.