Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Marco Island, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 607ft / 185mTotal length
  • $220,000Total costs
  • 99,605Total average daily traffic
  • 5,092Total average daily truck traffic
  • 163,816Total future (year 2041) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Marco Island
  • No street view available for this location

New bridges in Marco Island, FL - historical statistics
  • New bridges - historical statistics
  • 21960-1969
  • 41970-1979
  • 21980-1989
  • 32000-2009
  • 22010-2019
Average Bridge Daily Traffic in Marco Island, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.7%Very good
  • 61.5%Good
  • 7.7%Satisfactory
  • 23.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 76.9%Good
  • 23.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.7%Very good
  • 61.5%Good
  • 23.1%Satisfactory
  • 7.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 30.8%Very good
  • 61.5%Good
  • 7.7%Satisfactory
Find on map >>   Show street view

Structure Number: 30148,  Location: 7.0MI SOUTH OF US-41 (Lat: 25.963617,  Lng: -81.709683),  Route carried "on" structure: State highway 951,  Year Built: 1969,  Status: Open,  Structure Length: 48.62m (159.51ft),  Average Daily Traffic: 20,250 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 35,134 (year 2041),  Design Load: HS 20,  Features Intersected: BIG MARCO PASS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.194,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Navigation Control: Yes ( Vertical Clearance: 16.7m (54.8ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 16,  Length of Maximum Span: 36.9m (121.1ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 51.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.86m (15.94ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: March 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $220,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 30184,  Location: 6.5MI SOUTH OF US-41 (Lat: 25.932833,  Lng: -81.653528),  Route carried "on" structure: County highway 92,  Year Built: 1975,  Status: Open,  Structure Length: 56.10m (184.06ft),  Average Daily Traffic: 3,000 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,000 (year 2041),  Design Load: HS 20,  Features Intersected: MARCO CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.986,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Navigation Control: Yes ( Vertical Clearance: 16.5m (54.1ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 22,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 66.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Underwater Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 30207,  Location: 1.0 MI S/O CR-953 (Lat: 25.945581,  Lng: -81.732600),  Route carried "on" structure: City street 951,  Year Built: 1979,  Status: Open,  Structure Length: 2.48m (8.14ft),  Average Daily Traffic: 15,800 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 27,413 (year 2041),  Design Load: HS 20,  Features Intersected: CLAM BAY,  Facility Carried by Structure: N COLLIER BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.048,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.8m (58.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.4m (27.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 21.8m (71.5ft),  Out-to-Out Width: 25.8m (84.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 65.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 30293,  Location: 7.0 MI SOUTH OF US-41 (Lat: 25.963653,  Lng: -81.709878),  Route carried "on" structure: State highway 951,  Year Built: 2011,  Status: Open,  Structure Length: 48.77m (160.01ft),  Average Daily Traffic: 20,250 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 35,134 (year 2041),  Design Load: HL 93,  Features Intersected: BIG MARCO PASS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.194,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Navigation Control: Yes ( Vertical Clearance: 16.8m (55.1ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 44.9m (147.3ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 34113,  Location: 100ft. W/O HEATHWOOD (Lat: 25.923311,  Lng: -81.714325),  Route carried "on" structure: City street ,  Year Built: 1967,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 3,000 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,750 (year 2041),  Design Load: HS 20,  Features Intersected: SMOKEHOUSE CREEK,  Facility Carried by Structure: WINTERBERRY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.217,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 57.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 34119,  Location: 0.1 MI N/O SPINNAKER DR (Lat: 25.951111,  Lng: -81.743667),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,554 (year 2041),  Design Load: HS 20,  Features Intersected: CLAM BAY,  Facility Carried by Structure: BLACKMORE COURT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.2m (33.5ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 63.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3412,  Location: 0.1 MI N OF HERNANDO DR (Lat: 25.953597,  Lng: -81.741011),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 1,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,554 (year 2041),  Design Load: HS 20,  Features Intersected: COLLIER BAY,  Facility Carried by Structure: KENDALL DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 34126,  Location: 0.7MI S/O SR-92 (Lat: 25.927539,  Lng: -81.705619),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Posted for load-capacity,  Structure Length: 2.14m (7.02ft),  Average Daily Traffic: 620 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 775 (year 2041),  Design Load: HS 20,  Features Intersected: TIDAL CANAL,  Facility Carried by Structure: SANDHILL ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.1m (23.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.1m (23.3ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 39.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 34127,  Location: 200ft. N/O CR-92 (Lat: 25.937647,  Lng: -81.719547),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 2.58m (8.46ft),  Average Daily Traffic: 550 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,328 (year 2041),  Design Load: HS 20,  Features Intersected: TIDAL CANAL,  Facility Carried by Structure: SOUTH SEAS COURT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.4m (24.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.6m (28.2ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 61.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 36001,  Location: 0.3MI WEST OF CR-951 (Lat: 25.961569,  Lng: -81.722236),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 4.08m (13.39ft),  Average Daily Traffic: 500 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 625 (year 2041),  Design Load: HS 20,  Features Intersected: FACTORY BAY,  Facility Carried by Structure: N. BARFIELD DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.329,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.6m (44.6ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 50.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 36002,  Location: 1.3 MI N/O CR-92 (Lat: 25.949917,  Lng: -81.708167),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 7,500 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,375 (year 2041),  Design Load: HL 93,  Features Intersected: MARCO RIVER INLET,  Facility Carried by Structure: N. BARFIELD DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.182,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.9m (32.5ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 29.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 36003,  Location: 0.2 mi. W/O S Barfield Dr (Lat: 25.925917,  Lng: -81.702883),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 3.68m (12.07ft),  Average Daily Traffic: 1,275 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,594 (year 2041),  Design Load: HL 93,  Features Intersected: ROBERTS BAY,  Facility Carried by Structure: WINTERBERRY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.419,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.9m (32.5ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 30.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 36004,  Location: 0.4MI S OF CR-953 (Lat: 25.952033,  Lng: -81.730419),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 24,760 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 38,580 (year 2042),  Design Load: HL 93,  Features Intersected: SMOKEHOUSE BAY,  Facility Carried by Structure: COLLIER BLVD. SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.815,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.7m (113.8ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 0.0m,  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Critical Feature Inspection Date: January 2022,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Discuss Marco Island, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.