Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Rocklin, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 21Number of bridges
  • 200ft / 61.0mTotal length
  • 748,422Total average daily traffic
  • 85,528Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rocklin
  • No street view available for this location

New bridges in Rocklin, CA - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 31950-1959
  • 21960-1969
  • 21970-1979
  • 31980-1989
  • 11990-1999
  • 52000-2009
  • 42010-2019
Average Bridge Daily Traffic in Rocklin, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 58.3%Good
  • 16.7%Satisfactory
  • 25.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 75.0%Good
  • 16.7%Satisfactory
  • 8.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 75.0%Good
  • 16.7%Satisfactory
  • 8.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 16.7%Good
  • 50.0%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 19 009,  Location: 03-PLA-080-34.99 (Lat: 39.121611,  Lng: -120.940878),  Route carried "on" structure: Interstate 80,  Year Built: 1958,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 29,000 (year 2004),  Truck Traffic: 13%,  Average Future Daily Traffic: 48,944 (year 2041),  Design Load: HS 20,  Features Intersected: CARPENTER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.990,  Lanes on structure: 4,  Lanes under structure: 1,  Base Highway Network: Yes (,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 18.4m (60.4ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 18.4m (60.4ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 75.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 19 0094,  Location: 03-PLA-080-6.06-ROC (Lat: 38.788436,  Lng: -121.222522),  Route carried "on" structure: Interstate 80,  Year Built: 1959,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 92,000 (year 2009),  Truck Traffic: 8%,  Average Future Daily Traffic: 156,111 (year 2039),  Design Load: HS 20,  Features Intersected: ROCKLIN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.060,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 34.1m (111.9ft),  Skew: 34 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 34.1m (111.9ft),  Out-to-Out Width: 35.8m (117.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 19 0136L,  Location: 03-PLA-065-R8.76 (Lat: 38.805317,  Lng: -121.300411),  Route carried "on" structure: State highway 65,  Year Built: 1971,  Status: Open,  Structure Length: 3.98m (13.06ft),  Average Daily Traffic: 35,000 (year 2010),  Truck Traffic: 14%,  Average Future Daily Traffic: 37,368 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: PLEASANT GROVE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.760,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19 0137,  Location: 03-PLA-065-M8.59 (Lat: 38.802719,  Lng: -121.300028),  Route carried "on" structure: State highway 65,  Year Built: 1971,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 70,000 (year 2010),  Truck Traffic: 14%,  Average Future Daily Traffic: 74,736 (year 2043),  Features Intersected: LITTLE PLEASANT GROVE CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.590,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 19 0153S,  Location: 03-PLA-065-M8.15 (Lat: 38.796589,  Lng: -121.298411),  Route carried "on" structure: Ramp State highway 65,  Year Built: 1987,  Status: Open,  Structure Length: 6.28m (20.60ft),  Average Daily Traffic: 3,240 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,438 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 65
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.150,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.2m (102.4ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19 0174,  Location: 03-PLA-065-M8.07-ROC (Lat: 38.795478,  Lng: -121.297564),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 7.30m (23.95ft),  Average Daily Traffic: 10,000 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,820 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 65,  Facility Carried by Structure: BLUE OAKS BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 24.0m (78.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.8m (127.3ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 24.0m (78.7ft),  Out-to-Out Width: 26.4m (86.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19 0175,  Location: 03-PLA-065-M8.08-ROC (Lat: 38.795800,  Lng: -121.295694),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 3.16m (10.37ft),  Average Daily Traffic: 10,000 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,456 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: N65-BLUE OAKS OFF-RAMP,  Facility Carried by Structure: BLUE OAKS BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.0m (98.4ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 23.1m (75.8ft),  Out-to-Out Width: 25.4m (83.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19 0202,  Location: 03-PLA-065-R9.60 (Lat: 38.817147,  Lng: -121.300761),  Route carried "on" structure: City street ,  Year Built: 2011,  Status: Open,  Structure Length: 10.23m (33.56ft),  Average Daily Traffic: 1,200 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,842 (year 2039),  Design Load: HL 93,  Features Intersected: STATE ROUTE 65,  Facility Carried by Structure: SUNSET BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 50.9m (167.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 34.6m (113.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19 0204,  Location: 03-PLA-065-R10.57 (Lat: 38.831556,  Lng: -121.300500),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 9.66m (31.69ft),  Average Daily Traffic: 1,000 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 1,500 (year 2039),  Design Load: HL 93,  Features Intersected: STATE ROUTE 65,  Facility Carried by Structure: WHITNEY RANCH PRKY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 48.0m (157.5ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19C0006,  Location: 6.2 MI N OF SACTO CO.LINE (Lat: 38.796875,  Lng: -121.205547),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 10,106 (year 2010),  Truck Traffic: 8%,  Average Future Daily Traffic: 14,330 (year 2042),  Features Intersected: SECRET RAVINE,  Facility Carried by Structure: SIERRA COLLEGE BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 19C0051,  Location: 1.1 MI N DOUGLAS BLVD (Lat: 38.757392,  Lng: -121.163928),  Route carried "on" structure: County highway ,  Year Built: 1930,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 17,248 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 20,000 (year 2037),  Features Intersected: MINERS RAVINE,  Facility Carried by Structure: AUBURN FOLSOM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 19C0058,  Location: NEAR PACIFIC ST. (Lat: 38.782389,  Lng: -121.243578),  Route carried "on" structure: City street ,  Year Built: 1961,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 30,058 (year 2016),  Truck Traffic: 8%,  Average Future Daily Traffic: 40,943 (year 2042),  Design Load: HS 20,  Features Intersected: UP RR, BNSF RY, & AMTRAK,  Facility Carried by Structure: SUNSET BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.5m (54.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.3m (50.2ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19C0072,  Location: 0.3 MI E OF I-80 (Lat: 38.788339,  Lng: -121.220456),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 5,700 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 13,495 (year 2036),  Design Load: HS 20,  Features Intersected: SECRET RAVINE,  Facility Carried by Structure: ROCKLIN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 27.4m (89.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 94.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19C0273,  Location: 0.1 MI S OF ROCKLIN RD (Lat: 38.787428,  Lng: -121.220483),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 5.87m (19.26ft),  Average Daily Traffic: 1,170 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,500 (year 2037),  Design Load: HS 20,  Features Intersected: SECRET RAVINE,  Facility Carried by Structure: CHINA GARDEN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 19 0094,  Location: 03-PLA-080-6.06-ROC (Lat: 38.788436,  Lng: -121.222522),  Route carried "under" structure: City street ,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 1998),  Truck Traffic: 2%,  Features Intersected: ROCKLIN ROAD,  Facility Carried by Structure: INTERSTATE 80
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 19 0153S,  Location: 03-PLA-065-M8.15 (Lat: 38.796589,  Lng: -121.298411),  Route carried "under" structure: State highway 65,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 100,000 (year 2010),  Truck Traffic: 15%,  Features Intersected: STATE ROUTE 65
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 8.150,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 31.2m (102.4ft)

Find on map >>   Show street view

Structure Number: 19 0174,  Location: 03-PLA-065-M8.07-ROC (Lat: 38.795478,  Lng: -121.297564),  Route carried "under" structure: State highway 65,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 105,000 (year 2009),  Truck Traffic: 15%,  Features Intersected: STATE ROUTE 65,  Facility Carried by Structure: BLUE OAKS BLVD
Minimum Vertical Clearance: 5.91m (19.39ft),  Kilometerpoint: 8.070,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 38.8m (127.3ft)

Find on map >>   Show street view

Structure Number: 19 0175,  Location: 03-PLA-065-M8.08-ROC (Lat: 38.795800,  Lng: -121.295694),  Route carried "under" structure: Ramp State highway 65,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 20,000 (year 2003),  Truck Traffic: 5%,  Features Intersected: N65-BLUE OAKS OFF-RAMP,  Facility Carried by Structure: BLUE OAKS BLVD
Minimum Vertical Clearance: 5.35m (17.55ft),  Kilometerpoint: 8.080,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 30.0m (98.4ft)

Find on map >>   Show street view

Structure Number: 19 018,  Location: 03-PLA-080-7.10 (Lat: 38.803381,  Lng: -121.205581),  Route carried "under" structure: Interstate 80,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 92,000 (year 2009),  Truck Traffic: 8%,  Features Intersected: INTERSTATE 80,  Facility Carried by Structure: SIERRA COLLEGE BL
Minimum Vertical Clearance: 5.75m (18.86ft),  Kilometerpoint: 7.100,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 52.4m (171.9ft)

Find on map >>   Show street view

Structure Number: 19 0202,  Location: 03-PLA-065-R9.60 (Lat: 38.817147,  Lng: -121.300761),  Route carried "under" structure: State highway 65,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 50,500 (year 2009),  Truck Traffic: 13%,  Features Intersected: STATE ROUTE 65,  Facility Carried by Structure: SUNSET BLVD
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 9.600,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 50.9m (167.0ft)

Find on map >>   Show street view

Structure Number: 19 0204,  Location: 03-PLA-065-R10.57 (Lat: 38.831556,  Lng: -121.300500),  Route carried "under" structure: State highway 65,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 64,200 (year 2017),  Truck Traffic: 13%,  Features Intersected: STATE ROUTE 65,  Facility Carried by Structure: WHITNEY RANCH PRKY
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 10.570,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 48.0m (157.5ft)

Discuss Rocklin, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.