Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Florence-Graham, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 43ft / 12.8mTotal length
  • 245,470Total average daily traffic
  • 29,702Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Florence-Graham
  • No street view available for this location

New bridges in Florence-Graham, CA - historical statistics
  • New bridges - historical statistics
  • 31980-1989
  • 31990-1999
  • 72000-2009
Average Bridge Daily Traffic in Florence-Graham, CA
Average Bridge Truck Traffic in Florence-Graham, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Good
  • 57.1%Satisfactory
  • 28.6%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 85.7%Very good
  • 14.3%Good
Find on map >>   Show street view

Structure Number: 53C2128,  Location: 0.2MI N/O NADEAU ST (Lat: 33.970628,  Lng: -118.233806),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 505 (year 2012),  Average Future Daily Traffic: 556 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: ACTA,  Facility Carried by Structure: METRO CMMERCIAL DW
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C2129,  Location: 40FT E/O ALAMEDA ST (Lat: 33.967331,  Lng: -118.233072),  Route carried "on" structure: County highway L644,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 15,014 (year 2012),  Truck Traffic: 24%,  Average Future Daily Traffic: 18,017 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: ACTA,  Facility Carried by Structure: NADEAU ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 18.5m (60.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb or Sidewalk Widths: Left: 7.5m (24.6ft),  Right: 5.2m (17.1ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 31.6m (103.7ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C2131,  Location: 400FT N/O FIRESTONE BLVD (Lat: 33.958978,  Lng: -118.231242),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 306 (year 2012),  Truck Traffic: 24%,  Average Future Daily Traffic: 306 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: ACTA,  Facility Carried by Structure: HON ENTRANCE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C2132,  Location: 40FT E/O ALAMEDA ST (Lat: 33.957542,  Lng: -118.230917),  Route carried "on" structure: County highway L164,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 27,945 (year 2012),  Truck Traffic: 24%,  Average Future Daily Traffic: 33,534 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: ACTA,  Facility Carried by Structure: FIRESTONE BLVD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 26.3m (86.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb or Sidewalk Widths: Left: 12.4m (40.7ft),  Right: 6.4m (21.0ft),  Curb-To-Curb Width: 26.3m (86.3ft),  Out-to-Out Width: 44.1m (144.7ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C2133,  Location: 50FT E/O ALAMEDA ST (Lat: 33.953147,  Lng: -118.229956),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 11,400 (year 2012),  Truck Traffic: 24%,  Average Future Daily Traffic: 13,100 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: ACTA,  Facility Carried by Structure: 92ND ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb or Sidewalk Widths: Left: 3.9m (12.8ft),  Right: 6.4m (21.0ft),  Curb-To-Curb Width: 18.4m (60.4ft),  Out-to-Out Width: 29.2m (95.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C2134,  Location: 50FT E/O ALAMEDA ST (Lat: 33.946447,  Lng: -118.228486),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 15,758 (year 2012),  Truck Traffic: 24%,  Average Future Daily Traffic: 18,910 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: ACTA,  Facility Carried by Structure: TWEEDY BLVD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb or Sidewalk Widths: Left: 6.5m (21.3ft),  Right: 5.5m (18.0ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 31.7m (104.0ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C2229,  Location: 50FT E/O ALAMEDA ST (Lat: 33.972881,  Lng: -118.234283),  Route carried "on" structure: County highway ,  Year Built: 2007,  Status: Open,  Structure Length: 2.05m (6.73ft),  Average Daily Traffic: 909 (year 2012),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20,  Features Intersected: ACTA,  Facility Carried by Structure: 74TH ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb or Sidewalk Widths: Left: 5.1m (16.7ft),  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C1924L,  Location: 0.3MI W/O ALAMEDA (Lat: 33.989167,  Lng: -118.243425),  Route carried "under" structure: County highway L125,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 32,095 (year 2012),  Truck Traffic: 10%,  Features Intersected: SLAUSON AVE,  Facility Carried by Structure: LA MTR BLUE LN S
Minimum Vertical Clearance: 7.47m (24.51ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>   Show street view

Structure Number: 53C1924R,  Location: 0.3MI W/O ALAMEDA (Lat: 33.989164,  Lng: -118.243331),  Route carried "under" structure: County highway L125,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 32,095 (year 2012),  Truck Traffic: 10%,  Features Intersected: SLAUSON AVE,  Facility Carried by Structure: LA MTR BLUE LN N
Minimum Vertical Clearance: 7.47m (24.51ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>   Show street view

Structure Number: 53C1929,  Location: 0.3MI E/O COMPTON BLVD (Lat: 33.985428,  Lng: -118.243267),  Route carried "under" structure: County highway L124,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 3,768 (year 2012),  Truck Traffic: 1%,  Features Intersected: 60TH ST,  Facility Carried by Structure: LA METRO BLUE LN S
Minimum Vertical Clearance: 8.10m (26.57ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 53C1979,  Location: AT GRAHAM AVE (Lat: 33.960011,  Lng: -118.243317),  Route carried "under" structure: County highway ,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 35,225 (year 2012),  Truck Traffic: 6%,  Features Intersected: FIRESTONE BLVD,  Facility Carried by Structure: SP/UP RR
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.000,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 53C198,  Location: AT GRAHAM AVE (Lat: 33.960017,  Lng: -118.243225),  Route carried "under" structure: County highway ,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 35,225 (year 2012),  Truck Traffic: 6%,  Features Intersected: FIRESTONE BLVD,  Facility Carried by Structure: BLUE LINE LRT S
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.000,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.4m (99.7ft)

Find on map >>   Show street view

Structure Number: 53C1981,  Location: AT GRAHAM AVE (Lat: 33.960011,  Lng: -118.243131),  Route carried "under" structure: County highway ,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 35,225 (year 2012),  Truck Traffic: 6%,  Features Intersected: FIRESTONE BLVD,  Facility Carried by Structure: BLUE LINE LRT N
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.000,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.3m (106.0ft)

Discuss Florence-Graham, California (CA) on our hugely popular California forum.