Bridge Statistics for Golden Glades, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs
- National Bridge Inventory (NBI) Statistics
- 43Number of bridges
- 1,175ft / 358mTotal length
- 1,754,750Total average daily traffic
- 110,545Total average daily truck traffic
- National Bridge Inventory (NBI) Registered Bridges for Golden Glades
- No street view available for this location
- New bridges - historical statistics
- 21950-1959
- 171960-1969
- 31970-1979
- 211990-1999
- Bridge Condition - Deck
- 66.7%Good
- 33.3%Satisfactory
- Bridge Condition - Superstructure
- 58.3%Good
- 25.0%Satisfactory
- 16.7%Fair
Find on map >> Show street view
Structure Number: 870038, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.929947, Lng: -80.210547), Route carried "on" structure: State highway 91, Year Built: 1963, Year Reconstructed: 1987, Status: Open, Structure Length: 5.30m (17.39ft), Average Daily Traffic: 96,600 (year 2020), Truck Traffic: 11%, Average Future Daily Traffic: 167,601 (year 2042), Design Load: HS 20+Mod, Features Intersected: SR-826 PALMETTO EXPY
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 5, Base Highway Network: Yes, Toll: On toll road, Owner: State Toll Authority, Approaching Roadway Width: 20.4m (66.9ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 17.1m (56.1ft), Curb-To-Curb Width: 20.4m (66.9ft), Out-to-Out Width: 23.1m (75.8ft)
Condition: Deck: Good, Superstructure: Fair, Substructure: Good, Operating Rating: 52.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 31.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous
Structure Number: 870038, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.929947, Lng: -80.210547), Route carried "on" structure: State highway 91, Year Built: 1963, Year Reconstructed: 1987, Status: Open, Structure Length: 5.30m (17.39ft), Average Daily Traffic: 96,600 (year 2020), Truck Traffic: 11%, Average Future Daily Traffic: 167,601 (year 2042), Design Load: HS 20+Mod, Features Intersected: SR-826 PALMETTO EXPY
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 5, Base Highway Network: Yes, Toll: On toll road, Owner: State Toll Authority, Approaching Roadway Width: 20.4m (66.9ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 17.1m (56.1ft), Curb-To-Curb Width: 20.4m (66.9ft), Out-to-Out Width: 23.1m (75.8ft)
Condition: Deck: Good, Superstructure: Fair, Substructure: Good, Operating Rating: 52.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 31.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >> Show street view
Structure Number: 87004, Location: SR7 NB RAMP OVER SR9A GGI (Lat: 25.924983, Lng: -80.209558), Route carried "on" structure: Ramp US 441, Year Built: 1963, Status: Open, Structure Length: 7.28m (23.88ft), Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Average Future Daily Traffic: 58,990 (year 2042), Design Load: HS 20, Features Intersected: I-95 (SR-9A), Facility Carried by Structure: COMP SR-7
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 18.029, Lanes on structure: 2, Lanes under structure: 6, Owner: State Highway Agency, Approaching Roadway Width: 10.6m (34.8ft), Skew: 9 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 24.4m (80.1ft), Curb-To-Curb Width: 9.5m (31.2ft), Out-to-Out Width: 11.2m (36.7ft)
Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 52.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 33.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: High priority of corrective action, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2020, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 87004, Location: SR7 NB RAMP OVER SR9A GGI (Lat: 25.924983, Lng: -80.209558), Route carried "on" structure: Ramp US 441, Year Built: 1963, Status: Open, Structure Length: 7.28m (23.88ft), Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Average Future Daily Traffic: 58,990 (year 2042), Design Load: HS 20, Features Intersected: I-95 (SR-9A), Facility Carried by Structure: COMP SR-7
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 18.029, Lanes on structure: 2, Lanes under structure: 6, Owner: State Highway Agency, Approaching Roadway Width: 10.6m (34.8ft), Skew: 9 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 24.4m (80.1ft), Curb-To-Curb Width: 9.5m (31.2ft), Out-to-Out Width: 11.2m (36.7ft)
Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 52.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 33.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: High priority of corrective action, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2020, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870041, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.926883, Lng: -80.207350), Route carried "on" structure: State highway 826, Year Built: 1963, Status: Open, Structure Length: 9.17m (30.09ft), Average Daily Traffic: 56,000 (year 2018), Truck Traffic: 8%, Average Future Daily Traffic: 97,160 (year 2040), Design Load: HS 20, Features Intersected: I-95 (SR-9A)
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.399, Lanes on structure: 4, Lanes under structure: 7, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 19.2m (63.0ft), Skew: 34 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 22.0m (72.2ft), Curb-To-Curb Width: 19.2m (63.0ft), Out-to-Out Width: 22.3m (73.2ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 57.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: High priority of corrective action, Approach Roadway Alignment: Meets minimum limits, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2020, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870041, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.926883, Lng: -80.207350), Route carried "on" structure: State highway 826, Year Built: 1963, Status: Open, Structure Length: 9.17m (30.09ft), Average Daily Traffic: 56,000 (year 2018), Truck Traffic: 8%, Average Future Daily Traffic: 97,160 (year 2040), Design Load: HS 20, Features Intersected: I-95 (SR-9A)
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.399, Lanes on structure: 4, Lanes under structure: 7, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 19.2m (63.0ft), Skew: 34 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 22.0m (72.2ft), Curb-To-Curb Width: 19.2m (63.0ft), Out-to-Out Width: 22.3m (73.2ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 57.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: High priority of corrective action, Approach Roadway Alignment: Meets minimum limits, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2020, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870042, Location: SR826 TO I-95 GOLDEN GLAD (Lat: 25.927347, Lng: -80.206722), Route carried "on" structure: Ramp State highway 826, Year Built: 1963, Status: Open, Structure Length: 9.75m (31.99ft), Average Daily Traffic: 7,300 (year 2021), Truck Traffic: 4%, Average Future Daily Traffic: 12,666 (year 2041), Design Load: HS 20, Features Intersected: I-95 AND SR7 RAMP NB
Minimum Vertical Clearance: 30.45m (99.90ft), Kilometerpoint: 0.093, Lanes on structure: 1, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Skew: 2 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 28.3m (92.8ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 9.2m (30.2ft)
Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 47.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 29.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2021, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870042, Location: SR826 TO I-95 GOLDEN GLAD (Lat: 25.927347, Lng: -80.206722), Route carried "on" structure: Ramp State highway 826, Year Built: 1963, Status: Open, Structure Length: 9.75m (31.99ft), Average Daily Traffic: 7,300 (year 2021), Truck Traffic: 4%, Average Future Daily Traffic: 12,666 (year 2041), Design Load: HS 20, Features Intersected: I-95 AND SR7 RAMP NB
Minimum Vertical Clearance: 30.45m (99.90ft), Kilometerpoint: 0.093, Lanes on structure: 1, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Skew: 2 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 28.3m (92.8ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 9.2m (30.2ft)
Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 47.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 29.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2021, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870044, Location: SR-9 AT US-441 SB (Lat: 25.922572, Lng: -80.213922), Route carried "on" structure: Ramp State highway 9, Year Built: 1963, Status: Open, Structure Length: 4.63m (15.19ft), Average Daily Traffic: 12,750 (year 2020), Truck Traffic: 7%, Average Future Daily Traffic: 22,121 (year 2042), Design Load: HS 20, Features Intersected: US-441 SB
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 21.729, Lanes on structure: 2, Lanes under structure: 1, Owner: State Highway Agency, Approaching Roadway Width: 9.6m (31.5ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 18.3m (60.0ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 8.7m (28.5ft), Out-to-Out Width: 10.4m (34.1ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 59.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2020, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870044, Location: SR-9 AT US-441 SB (Lat: 25.922572, Lng: -80.213922), Route carried "on" structure: Ramp State highway 9, Year Built: 1963, Status: Open, Structure Length: 4.63m (15.19ft), Average Daily Traffic: 12,750 (year 2020), Truck Traffic: 7%, Average Future Daily Traffic: 22,121 (year 2042), Design Load: HS 20, Features Intersected: US-441 SB
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 21.729, Lanes on structure: 2, Lanes under structure: 1, Owner: State Highway Agency, Approaching Roadway Width: 9.6m (31.5ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 18.3m (60.0ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 8.7m (28.5ft), Out-to-Out Width: 10.4m (34.1ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 59.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2020, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870046, Location: SR7 & SR826 SB RAMP (Lat: 25.927444, Lng: -80.208083), Route carried "on" structure: US 826, Year Built: 1963, Status: Open, Structure Length: 5.21m (17.09ft), Average Daily Traffic: 56,000 (year 2018), Truck Traffic: 8%, Average Future Daily Traffic: 97,160 (year 2040), Design Load: HS 20, Features Intersected: SR 826 OVER I95 SB RAMP
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.315, Lanes on structure: 4, Lanes under structure: 3, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 17.1m (56.1ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 22.6m (74.1ft), Curb-To-Curb Width: 17.1m (56.1ft), Out-to-Out Width: 20.1m (65.9ft)
Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 70.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 45.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Underclear: Meets minimum limits, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2020, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870046, Location: SR7 & SR826 SB RAMP (Lat: 25.927444, Lng: -80.208083), Route carried "on" structure: US 826, Year Built: 1963, Status: Open, Structure Length: 5.21m (17.09ft), Average Daily Traffic: 56,000 (year 2018), Truck Traffic: 8%, Average Future Daily Traffic: 97,160 (year 2040), Design Load: HS 20, Features Intersected: SR 826 OVER I95 SB RAMP
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.315, Lanes on structure: 4, Lanes under structure: 3, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 17.1m (56.1ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 22.6m (74.1ft), Curb-To-Curb Width: 17.1m (56.1ft), Out-to-Out Width: 20.1m (65.9ft)
Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 70.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 45.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Underclear: Meets minimum limits, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2020, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.928944, Lng: -80.205031), Route carried "on" structure: Ramp Interstate 95, Year Built: 1963, Status: Open, Structure Length: 8.05m (26.41ft), Average Daily Traffic: 13,500 (year 2022), Truck Traffic: 4%, Average Future Daily Traffic: 23,422 (year 2042), Design Load: HS 20, Features Intersected: US-441 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.164, Lanes on structure: 1, Lanes under structure: 1, Owner: State Highway Agency, Approaching Roadway Width: 6.1m (20.0ft), Skew: 9 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 25.1m (82.3ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 6.7m (22.0ft), Out-to-Out Width: 8.5m (27.9ft)
Condition: Deck: Good, Superstructure: Fair, Substructure: Good, Operating Rating: 58.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 35.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Underclear: Meets minimum limits, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.928944, Lng: -80.205031), Route carried "on" structure: Ramp Interstate 95, Year Built: 1963, Status: Open, Structure Length: 8.05m (26.41ft), Average Daily Traffic: 13,500 (year 2022), Truck Traffic: 4%, Average Future Daily Traffic: 23,422 (year 2042), Design Load: HS 20, Features Intersected: US-441 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.164, Lanes on structure: 1, Lanes under structure: 1, Owner: State Highway Agency, Approaching Roadway Width: 6.1m (20.0ft), Skew: 9 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 25.1m (82.3ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 6.7m (22.0ft), Out-to-Out Width: 8.5m (27.9ft)
Condition: Deck: Good, Superstructure: Fair, Substructure: Good, Operating Rating: 58.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 35.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Underclear: Meets minimum limits, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 87016, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.931814, Lng: -80.212531), Route carried "on" structure: Ramp State highway 91, Year Built: 1963, Status: Open, Structure Length: 9.14m (29.99ft), Average Daily Traffic: 47,000 (year 2020), Truck Traffic: 5%, Average Future Daily Traffic: 81,545 (year 2042), Design Load: HS 20+Mod, Features Intersected: SR 91 TPK
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.299, Lanes on structure: 2, Lanes under structure: 3, Toll: On toll road, Owner: State Toll Authority, Approaching Roadway Width: 8.8m (28.9ft), Skew: 5 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 26.2m (86.0ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.8m (2.6ft), Curb-To-Curb Width: 8.8m (28.9ft), Out-to-Out Width: 10.4m (34.1ft)
Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 50.6 metric tons, Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR), Inventory Rating: 39.2 metric tons, Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 87016, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.931814, Lng: -80.212531), Route carried "on" structure: Ramp State highway 91, Year Built: 1963, Status: Open, Structure Length: 9.14m (29.99ft), Average Daily Traffic: 47,000 (year 2020), Truck Traffic: 5%, Average Future Daily Traffic: 81,545 (year 2042), Design Load: HS 20+Mod, Features Intersected: SR 91 TPK
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.299, Lanes on structure: 2, Lanes under structure: 3, Toll: On toll road, Owner: State Toll Authority, Approaching Roadway Width: 8.8m (28.9ft), Skew: 5 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 26.2m (86.0ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.8m (2.6ft), Curb-To-Curb Width: 8.8m (28.9ft), Out-to-Out Width: 10.4m (34.1ft)
Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 50.6 metric tons, Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR), Inventory Rating: 39.2 metric tons, Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 87047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.920333, Lng: -80.211431), Route carried "on" structure: Ramp Interstate 95, Year Built: 1976, Status: Open, Structure Length: 27.58m (90.49ft), Average Daily Traffic: 350 (year 2020), Truck Traffic: 14%, Average Future Daily Traffic: 607 (year 2042), Design Load: HS 20, Features Intersected: I-95 SB & US441
Minimum Vertical Clearance: 4.93m (16.17ft), Kilometerpoint: 0.201, Lanes on structure: 2, Lanes under structure: 8, Toll: On Interstate toll segment, Owner: State Highway Agency, Approaching Roadway Width: 12.8m (42.0ft), Skew: 39 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 65.8m (215.9ft), Curb-To-Curb Width: 4.5m (14.8ft), Out-to-Out Width: 14.7m (48.2ft)
Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 73.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 44.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: High priority of replacement, Underclear: Meets minimum limits, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: June 2021, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 87047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.920333, Lng: -80.211431), Route carried "on" structure: Ramp Interstate 95, Year Built: 1976, Status: Open, Structure Length: 27.58m (90.49ft), Average Daily Traffic: 350 (year 2020), Truck Traffic: 14%, Average Future Daily Traffic: 607 (year 2042), Design Load: HS 20, Features Intersected: I-95 SB & US441
Minimum Vertical Clearance: 4.93m (16.17ft), Kilometerpoint: 0.201, Lanes on structure: 2, Lanes under structure: 8, Toll: On Interstate toll segment, Owner: State Highway Agency, Approaching Roadway Width: 12.8m (42.0ft), Skew: 39 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 65.8m (215.9ft), Curb-To-Curb Width: 4.5m (14.8ft), Out-to-Out Width: 14.7m (48.2ft)
Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 73.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 44.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: High priority of replacement, Underclear: Meets minimum limits, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: June 2021, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870601, Location: 0.7 MILES S OF MIAMI GDNS (Lat: 25.928536, Lng: -80.212161), Route carried "on" structure: Ramp State highway 91, Year Built: 1956, Year Reconstructed: 1980, Status: Open, Structure Length: 8.84m (29.00ft), Average Daily Traffic: 19,500 (year 2020), Truck Traffic: 17%, Average Future Daily Traffic: 33,832 (year 2042), Design Load: HL 93, Features Intersected: SR 826 PALMETTO EXPY
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.396, Lanes on structure: 4, Lanes under structure: 7, Base Highway Network: Yes, Toll: On toll road, Owner: State Toll Authority, Approaching Roadway Width: 33.2m (108.9ft), Skew: 33 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 29.0m (95.1ft), Curb-To-Curb Width: 33.5m (109.9ft), Out-to-Out Width: 35.0m (114.8ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 43.7 metric tons, Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR), Inventory Rating: 33.7 metric tons, Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870601, Location: 0.7 MILES S OF MIAMI GDNS (Lat: 25.928536, Lng: -80.212161), Route carried "on" structure: Ramp State highway 91, Year Built: 1956, Year Reconstructed: 1980, Status: Open, Structure Length: 8.84m (29.00ft), Average Daily Traffic: 19,500 (year 2020), Truck Traffic: 17%, Average Future Daily Traffic: 33,832 (year 2042), Design Load: HL 93, Features Intersected: SR 826 PALMETTO EXPY
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.396, Lanes on structure: 4, Lanes under structure: 7, Base Highway Network: Yes, Toll: On toll road, Owner: State Toll Authority, Approaching Roadway Width: 33.2m (108.9ft), Skew: 33 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 29.0m (95.1ft), Curb-To-Curb Width: 33.5m (109.9ft), Out-to-Out Width: 35.0m (114.8ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 43.7 metric tons, Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR), Inventory Rating: 33.7 metric tons, Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2022, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "on" structure: Interstate 95, Year Built: 1994, Status: Open, Structure Length: 192.27m (630.81ft), Average Daily Traffic: 25,000 (year 2020), Truck Traffic: 4%, Average Future Daily Traffic: 43,375 (year 2042), Design Load: HS 20, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 6.286, Lanes on structure: 1, Lanes under structure: 29, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 8.4m (27.6ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 48, Length of Maximum Span: 46.9m (153.9ft), Curb-To-Curb Width: 8.4m (27.6ft), Out-to-Out Width: 9.3m (30.5ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 57.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2021, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "on" structure: Interstate 95, Year Built: 1994, Status: Open, Structure Length: 192.27m (630.81ft), Average Daily Traffic: 25,000 (year 2020), Truck Traffic: 4%, Average Future Daily Traffic: 43,375 (year 2042), Design Load: HS 20, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 6.286, Lanes on structure: 1, Lanes under structure: 29, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 8.4m (27.6ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 48, Length of Maximum Span: 46.9m (153.9ft), Curb-To-Curb Width: 8.4m (27.6ft), Out-to-Out Width: 9.3m (30.5ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 57.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2021, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "on" structure: Interstate 95, Year Built: 1994, Status: Open, Structure Length: 70.81m (232.32ft), Average Daily Traffic: 25,000 (year 2020), Truck Traffic: 4%, Average Future Daily Traffic: 43,375 (year 2042), Design Load: HS 20, Features Intersected: GOLDEN GLADES INTER
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 11.463, Lanes on structure: 1, Lanes under structure: 8, Base Highway Network: Yes, Toll: On Interstate toll segment, Owner: State Highway Agency, Approaching Roadway Width: 8.4m (27.6ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Number Of Approach Spans: 16, Length of Maximum Span: 45.7m (149.9ft), Curb-To-Curb Width: 8.4m (27.6ft), Out-to-Out Width: 9.3m (30.5ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 65.2 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 39.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2021, Deck Structure Type: Concrete Cast-file-Place
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "on" structure: Interstate 95, Year Built: 1994, Status: Open, Structure Length: 70.81m (232.32ft), Average Daily Traffic: 25,000 (year 2020), Truck Traffic: 4%, Average Future Daily Traffic: 43,375 (year 2042), Design Load: HS 20, Features Intersected: GOLDEN GLADES INTER
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 11.463, Lanes on structure: 1, Lanes under structure: 8, Base Highway Network: Yes, Toll: On Interstate toll segment, Owner: State Highway Agency, Approaching Roadway Width: 8.4m (27.6ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Number Of Approach Spans: 16, Length of Maximum Span: 45.7m (149.9ft), Curb-To-Curb Width: 8.4m (27.6ft), Out-to-Out Width: 9.3m (30.5ft)
Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 65.2 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 39.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2021, Deck Structure Type: Concrete Cast-file-Place
Find on map >> Show street view
Structure Number: 870038, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.929947, Lng: -80.210547), Route carried "under" structure: State highway 826, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 58,000 (year 2020), Truck Traffic: 6%, Features Intersected: SR-826 PALMETTO EXPY, Facility Carried by Structure: SR91 TPK N/S
Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 38.914, Lanes on structure: 4, Lanes under structure: 5, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 17.1m (56.1ft)
Structure Number: 870038, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.929947, Lng: -80.210547), Route carried "under" structure: State highway 826, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 58,000 (year 2020), Truck Traffic: 6%, Features Intersected: SR-826 PALMETTO EXPY, Facility Carried by Structure: SR91 TPK N/S
Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 38.914, Lanes on structure: 4, Lanes under structure: 5, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 17.1m (56.1ft)
Find on map >> Show street view
Structure Number: 87004, Location: SR7 NB RAMP OVER SR9A GGI (Lat: 25.924983, Lng: -80.209558), Route carried "under" structure: Interstate 95, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 157,500 (year 2020), Truck Traffic: 5%, Features Intersected: I-95 (SR-9A), Facility Carried by Structure: COMP SR-7
Minimum Vertical Clearance: 4.37m (14.34ft), Kilometerpoint: 20.305, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 24.4m (80.1ft)
Structure Number: 87004, Location: SR7 NB RAMP OVER SR9A GGI (Lat: 25.924983, Lng: -80.209558), Route carried "under" structure: Interstate 95, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 157,500 (year 2020), Truck Traffic: 5%, Features Intersected: I-95 (SR-9A), Facility Carried by Structure: COMP SR-7
Minimum Vertical Clearance: 4.37m (14.34ft), Kilometerpoint: 20.305, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 24.4m (80.1ft)
Find on map >> Show street view
Structure Number: 870041, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.926883, Lng: -80.207350), Route carried "under" structure: Interstate 7, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: I-95 (SR-9A), Facility Carried by Structure: COMP SR-826
Minimum Vertical Clearance: 4.36m (14.30ft), Kilometerpoint: 18.403, Lanes on structure: 4, Lanes under structure: 6, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 22.0m (72.2ft)
Structure Number: 870041, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.926883, Lng: -80.207350), Route carried "under" structure: Interstate 7, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: I-95 (SR-9A), Facility Carried by Structure: COMP SR-826
Minimum Vertical Clearance: 4.36m (14.30ft), Kilometerpoint: 18.403, Lanes on structure: 4, Lanes under structure: 6, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 22.0m (72.2ft)
Find on map >> Show street view
Structure Number: 870042, Location: SR826 TO I-95 GOLDEN GLAD (Lat: 25.927347, Lng: -80.206722), Route carried "under" structure: Ramp US 441, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2021), Truck Traffic: 5%, Features Intersected: I-95 AND SR7 RAMP NB, Facility Carried by Structure: SR-826 TO I-95SB
Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 18.493, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 28.3m (92.8ft)
Structure Number: 870042, Location: SR826 TO I-95 GOLDEN GLAD (Lat: 25.927347, Lng: -80.206722), Route carried "under" structure: Ramp US 441, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2021), Truck Traffic: 5%, Features Intersected: I-95 AND SR7 RAMP NB, Facility Carried by Structure: SR-826 TO I-95SB
Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 18.493, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 28.3m (92.8ft)
Find on map >> Show street view
Structure Number: 870042, Location: SR826 TO I-95 GOLDEN GLAD (Lat: 25.927347, Lng: -80.206722), Route carried "under" structure: Interstate 95, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 157,500 (year 2021), Truck Traffic: 5%, Features Intersected: I-95 AND SR7 RAMP NB
Minimum Vertical Clearance: 4.36m (14.30ft), Kilometerpoint: 20.687, Lanes on structure: 1, Lanes under structure: 7, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 28.3m (92.8ft)
Structure Number: 870042, Location: SR826 TO I-95 GOLDEN GLAD (Lat: 25.927347, Lng: -80.206722), Route carried "under" structure: Interstate 95, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 157,500 (year 2021), Truck Traffic: 5%, Features Intersected: I-95 AND SR7 RAMP NB
Minimum Vertical Clearance: 4.36m (14.30ft), Kilometerpoint: 20.687, Lanes on structure: 1, Lanes under structure: 7, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 28.3m (92.8ft)
Find on map >> Show street view
Structure Number: 870044, Location: SR-9 AT US-441 SB (Lat: 25.922572, Lng: -80.213922), Route carried "under" structure: US 441, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2020), Truck Traffic: 5%, Features Intersected: US-441 SB, Facility Carried by Structure: SR-9 NB Ramp
Minimum Vertical Clearance: 4.48m (14.70ft), Kilometerpoint: 1.423, Lanes on structure: 2, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 18.3m (60.0ft)
Structure Number: 870044, Location: SR-9 AT US-441 SB (Lat: 25.922572, Lng: -80.213922), Route carried "under" structure: US 441, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2020), Truck Traffic: 5%, Features Intersected: US-441 SB, Facility Carried by Structure: SR-9 NB Ramp
Minimum Vertical Clearance: 4.48m (14.70ft), Kilometerpoint: 1.423, Lanes on structure: 2, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 18.3m (60.0ft)
Find on map >> Show street view
Structure Number: 870046, Location: SR7 & SR826 SB RAMP (Lat: 25.927444, Lng: -80.208083), Route carried "under" structure: State highway 826, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2015), Truck Traffic: 7%, Features Intersected: SR 826 OVER I95 SB RAMP
Minimum Vertical Clearance: 4.26m (13.98ft), Kilometerpoint: 18.496, Lanes on structure: 4, Lanes under structure: 3, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 22.6m (74.1ft)
Structure Number: 870046, Location: SR7 & SR826 SB RAMP (Lat: 25.927444, Lng: -80.208083), Route carried "under" structure: State highway 826, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2015), Truck Traffic: 7%, Features Intersected: SR 826 OVER I95 SB RAMP
Minimum Vertical Clearance: 4.26m (13.98ft), Kilometerpoint: 18.496, Lanes on structure: 4, Lanes under structure: 3, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 22.6m (74.1ft)
Find on map >> Show street view
Structure Number: 870047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.928944, Lng: -80.205031), Route carried "under" structure: Ramp US 441, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 13,500 (year 2022), Truck Traffic: 4%, Features Intersected: US-441 RAMP
Minimum Vertical Clearance: 4.51m (14.80ft), Kilometerpoint: 0.238, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 25.1m (82.3ft)
Structure Number: 870047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.928944, Lng: -80.205031), Route carried "under" structure: Ramp US 441, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 13,500 (year 2022), Truck Traffic: 4%, Features Intersected: US-441 RAMP
Minimum Vertical Clearance: 4.51m (14.80ft), Kilometerpoint: 0.238, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 25.1m (82.3ft)
Find on map >> Show street view
Structure Number: 87016, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.931814, Lng: -80.212531), Route carried "under" structure: State highway 91, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 96,600 (year 2020), Truck Traffic: 11%, Features Intersected: SR 91 TPK
Minimum Vertical Clearance: 4.66m (15.29ft), Kilometerpoint: 0.309, Lanes on structure: 2, Lanes under structure: 3, Toll: On toll road, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 26.2m (86.0ft)
Structure Number: 87016, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.931814, Lng: -80.212531), Route carried "under" structure: State highway 91, Year Built: 1963, Structure Length: 0. m, Average Daily Traffic: 96,600 (year 2020), Truck Traffic: 11%, Features Intersected: SR 91 TPK
Minimum Vertical Clearance: 4.66m (15.29ft), Kilometerpoint: 0.309, Lanes on structure: 2, Lanes under structure: 3, Toll: On toll road, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 26.2m (86.0ft)
Find on map >> Show street view
Structure Number: 87047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.920333, Lng: -80.211431), Route carried "under" structure: Interstate 95, Year Built: 1976, Structure Length: 0. m, Average Daily Traffic: 117,000 (year 2020), Truck Traffic: 5%, Features Intersected: I-95 SB & US441
Minimum Vertical Clearance: 6.07m (19.91ft), Kilometerpoint: 19.755, Lanes on structure: 2, Lanes under structure: 5, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 65.8m (215.9ft)
Structure Number: 87047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.920333, Lng: -80.211431), Route carried "under" structure: Interstate 95, Year Built: 1976, Structure Length: 0. m, Average Daily Traffic: 117,000 (year 2020), Truck Traffic: 5%, Features Intersected: I-95 SB & US441
Minimum Vertical Clearance: 6.07m (19.91ft), Kilometerpoint: 19.755, Lanes on structure: 2, Lanes under structure: 5, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 65.8m (215.9ft)
Find on map >> Show street view
Structure Number: 87047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.920333, Lng: -80.211431), Route carried "under" structure: US 441, Year Built: 1976, Structure Length: 0. m, Average Daily Traffic: 14,750 (year 2020), Truck Traffic: 9%, Features Intersected: I-95 SB & US441, Facility Carried by Structure: PRK LOT RAMP- I-95
Minimum Vertical Clearance: 5.73m (18.80ft), Kilometerpoint: 17.201, Lanes on structure: 2, Lanes under structure: 3, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 65.8m (215.9ft)
Structure Number: 87047, Location: GOLDEN GLADES INTERCHANGE (Lat: 25.920333, Lng: -80.211431), Route carried "under" structure: US 441, Year Built: 1976, Structure Length: 0. m, Average Daily Traffic: 14,750 (year 2020), Truck Traffic: 9%, Features Intersected: I-95 SB & US441, Facility Carried by Structure: PRK LOT RAMP- I-95
Minimum Vertical Clearance: 5.73m (18.80ft), Kilometerpoint: 17.201, Lanes on structure: 2, Lanes under structure: 3, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 65.8m (215.9ft)
Find on map >> Show street view
Structure Number: 870601, Location: 0.7 MILES S OF MIAMI GDNS (Lat: 25.928536, Lng: -80.212161), Route carried "under" structure: State highway 826, Year Built: 1956, Structure Length: 0. m, Average Daily Traffic: 129,000 (year 2020), Truck Traffic: 6%, Features Intersected: SR 826 PALMETTO EXPY, Facility Carried by Structure: SR91 TPK NB-SB 0.0
Minimum Vertical Clearance: 5.21m (17.09ft), Kilometerpoint: 38.759, Lanes on structure: 4, Lanes under structure: 7, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 29.0m (95.1ft)
Structure Number: 870601, Location: 0.7 MILES S OF MIAMI GDNS (Lat: 25.928536, Lng: -80.212161), Route carried "under" structure: State highway 826, Year Built: 1956, Structure Length: 0. m, Average Daily Traffic: 129,000 (year 2020), Truck Traffic: 6%, Features Intersected: SR 826 PALMETTO EXPY, Facility Carried by Structure: SR91 TPK NB-SB 0.0
Minimum Vertical Clearance: 5.21m (17.09ft), Kilometerpoint: 38.759, Lanes on structure: 4, Lanes under structure: 7, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 29.0m (95.1ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 23,000 (year 2020), Truck Traffic: 12%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 17.07m (56.00ft), Kilometerpoint: 0.285, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 23,000 (year 2020), Truck Traffic: 12%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 17.07m (56.00ft), Kilometerpoint: 0.285, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 12,500 (year 2019), Truck Traffic: 10%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 16.70m (54.79ft), Kilometerpoint: 0.000, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 12,500 (year 2019), Truck Traffic: 10%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 16.70m (54.79ft), Kilometerpoint: 0.000, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 5.88m (19.29ft), Kilometerpoint: 17.928, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 5.88m (19.29ft), Kilometerpoint: 17.928, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 78,750 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 9.94m (32.61ft), Kilometerpoint: 21.176, Lanes on structure: 1, Lanes under structure: 3, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 78,750 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 9.94m (32.61ft), Kilometerpoint: 21.176, Lanes on structure: 1, Lanes under structure: 3, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate , Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 400 (year 2020), Truck Traffic: 11%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 0.055, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate , Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 400 (year 2020), Truck Traffic: 11%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 0.055, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 78,750 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 18.90m (62.01ft), Kilometerpoint: 19.927, Lanes on structure: 1, Lanes under structure: 3, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 78,750 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 18.90m (62.01ft), Kilometerpoint: 19.927, Lanes on structure: 1, Lanes under structure: 3, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 47,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 7.77m (25.49ft), Kilometerpoint: 0.360, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 47,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 7.77m (25.49ft), Kilometerpoint: 0.360, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 19.82m (65.03ft), Kilometerpoint: 0.198, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 19.82m (65.03ft), Kilometerpoint: 0.198, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 22.80m (74.80ft), Kilometerpoint: 0.016, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 22.80m (74.80ft), Kilometerpoint: 0.016, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 19.81m (64.99ft), Kilometerpoint: 17.928, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 19.81m (64.99ft), Kilometerpoint: 17.928, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 23.47m (77.00ft), Kilometerpoint: 0.909, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter.
Minimum Vertical Clearance: 23.47m (77.00ft), Kilometerpoint: 0.909, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 4,500 (year 2020), Truck Traffic: 4%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 23.62m (77.49ft), Kilometerpoint: 0.014, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 4,500 (year 2020), Truck Traffic: 4%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 23.62m (77.49ft), Kilometerpoint: 0.014, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 4,500 (year 2020), Truck Traffic: 4%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 11.95m (39.21ft), Kilometerpoint: 0.182, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 4,500 (year 2020), Truck Traffic: 4%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 11.95m (39.21ft), Kilometerpoint: 0.182, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 7.96m (26.12ft), Kilometerpoint: 0.129, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 20,000 (year 2020), Truck Traffic: 5%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 7.96m (26.12ft), Kilometerpoint: 0.129, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: US 91, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 49,500 (year 2020), Truck Traffic: 4%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 11.89m (39.01ft), Kilometerpoint: 0.253, Lanes on structure: 1, Lanes under structure: 5, Toll: On toll road, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Structure Number: 870774, Location: I95 SB HOV AT GG INTERCHN (Lat: 25.926636, Lng: -80.209936), Route carried "under" structure: US 91, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 49,500 (year 2020), Truck Traffic: 4%, Features Intersected: Golden Glades Inter., Facility Carried by Structure: I-95SB HOV(870952)
Minimum Vertical Clearance: 11.89m (39.01ft), Kilometerpoint: 0.253, Lanes on structure: 1, Lanes under structure: 5, Toll: On toll road, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 46.9m (153.9ft)
Find on map >> Show street view
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 47,000 (year 2020), Truck Traffic: 5%, Features Intersected: GOLDEN GLADES INTER
Minimum Vertical Clearance: 7.77m (25.49ft), Kilometerpoint: 0.283, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: Ramp Interstate 95, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 47,000 (year 2020), Truck Traffic: 5%, Features Intersected: GOLDEN GLADES INTER
Minimum Vertical Clearance: 7.77m (25.49ft), Kilometerpoint: 0.283, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Find on map >> Show street view
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: GOLDEN GLADES INTER, Facility Carried by Structure: I95NB EXPRESS LANE
Minimum Vertical Clearance: 19.93m (65.39ft), Kilometerpoint: 17.938, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 34,000 (year 2020), Truck Traffic: 5%, Features Intersected: GOLDEN GLADES INTER, Facility Carried by Structure: I95NB EXPRESS LANE
Minimum Vertical Clearance: 19.93m (65.39ft), Kilometerpoint: 17.938, Lanes on structure: 1, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Find on map >> Show street view
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: GOLDEN GLADES INTER, Facility Carried by Structure: I95NB EXPRESS LANE
Minimum Vertical Clearance: 22.80m (74.80ft), Kilometerpoint: 0.185, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: GOLDEN GLADES INTER, Facility Carried by Structure: I95NB EXPRESS LANE
Minimum Vertical Clearance: 22.80m (74.80ft), Kilometerpoint: 0.185, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Find on map >> Show street view
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: GOLDEN GLADES INTER, Facility Carried by Structure: I95NB EXPRESS LANE
Minimum Vertical Clearance: 20.36m (66.80ft), Kilometerpoint: 0.029, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)
Structure Number: 870952, Location: I95 NB HOV AT GG INTERCHN (Lat: 25.924317, Lng: -80.210944), Route carried "under" structure: Ramp US 441, Year Built: 1994, Structure Length: 0. m, Average Daily Traffic: 5,500 (year 2020), Truck Traffic: 12%, Features Intersected: GOLDEN GLADES INTER, Facility Carried by Structure: I95NB EXPRESS LANE
Minimum Vertical Clearance: 20.36m (66.80ft), Kilometerpoint: 0.029, Lanes on structure: 1, Lanes under structure: 1, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.7m (149.9ft)