Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Campbell, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 25Number of bridges
  • 256ft / 77.5mTotal length
  • $1,965,000Total costs
  • 1,491,946Total average daily traffic
  • 92,649Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Campbell
  • No street view available for this location

New bridges in Campbell, CA - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 61950-1959
  • 81960-1969
  • 51970-1979
  • 41990-1999
  • 12000-2009
Reconstructed bridges in Campbell, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21960-1969
  • 11970-1979
  • 11980-1989
Average Bridge Daily Traffic in Campbell, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 75.0%Good
  • 16.7%Fair
  • 8.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 91.7%Good
  • 8.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 91.7%Good
  • 8.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Very good
  • 11.1%Good
  • 11.1%Satisfactory
  • 11.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 37 0133,  Location: 04-SCL-017-11.80-CMB (Lat: 37.287058,  Lng: -121.936606),  Route carried "on" structure: State highway 17,  Year Built: 1959,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 4.08m (13.39ft),  Average Daily Traffic: 151,200 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 197,000 (year 2038),  Design Load: HS 20,  Features Intersected: CAMPBELL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.800,  Lanes on structure: 8,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 42.1m (138.1ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 41.6m (136.5ft),  Out-to-Out Width: 42.9m (140.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0134,  Location: 04-SCL-017-12.03-CMB (Lat: 37.290186,  Lng: -121.936256),  Route carried "on" structure: State highway 17,  Year Built: 1959,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 151,200 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 197,000 (year 2038),  Design Load: HS 20,  Features Intersected: LOS GATOS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.030,  Lanes on structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 44.8m (147.0ft),  Skew: 31 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 44.5m (146.0ft),  Out-to-Out Width: 45.8m (150.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0136,  Location: 04-SCL-017-12.34-CMB (Lat: 37.294236,  Lng: -121.938583),  Route carried "on" structure: City street C199,  Year Built: 1959,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 6.83m (22.41ft),  Average Daily Traffic: 25,336 (year 2010),  Truck Traffic: 2%,  Average Future Daily Traffic: 33,000 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 17,  Facility Carried by Structure: HAMILTON AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 25.7m (84.3ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 25.7m (84.3ft),  Out-to-Out Width: 30.9m (101.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0147,  Location: 04-SCL-017-10.50-CMB (Lat: 37.270458,  Lng: -121.947142),  Route carried "on" structure: State highway 17,  Year Built: 1971,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 151,200 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 197,000 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: CAMDEN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.500,  Lanes on structure: 7,  Lanes under structure: 9,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 51.8m (169.9ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.3m (119.1ft),  Curb-To-Curb Width: 46.0m (150.9ft),  Out-to-Out Width: 49.7m (163.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0053,  Location: 0.01 MI N SH 17 (Lat: 37.272033,  Lng: -121.949011),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 62,140 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 77,469 (year 2044),  Design Load: HS 20,  Features Intersected: LOS GATOS CREEK,  Facility Carried by Structure: SAN TOMAS EXPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 9,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 35.4m (116.1ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 35.4m (116.1ft),  Out-to-Out Width: 39.0m (128.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2022,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0083,  Location: AT WINCHESTER BLVD (Lat: 37.273750,  Lng: -121.953206),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 9.36m (30.71ft),  Average Daily Traffic: 62,140 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 53,263 (year 2044),  Design Load: HS 20,  Features Intersected: WINCHESTER BLVD & UP RR,  Facility Carried by Structure: SAN TOMAS EXPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 9,  Owner: County Highway Agency,  Approaching Roadway Width: 27.7m (90.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 25.8m (84.6ft),  Out-to-Out Width: 28.9m (94.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0083K,  Location: AT WINCHESTER BLVD (Lat: 37.272350,  Lng: -121.953633),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 14.95m (49.05ft),  Average Daily Traffic: 6,500 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,285 (year 2042),  Features Intersected: UP RR, DELL AVE,  Facility Carried by Structure: SAN TOMAS EXPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 14.79m (48.52ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Critical Feature Inspection Date: July 2020,  Bridge Improvement Cost: $1,170,000,  Roadway Improvement Cost: $234,000,  Total Project Cost: $1,965,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0083S,  Location: WINCHESTER BLVD (Lat: 37.273781,  Lng: -121.951956),  Route carried "on" structure: Ramp County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 16.66m (54.66ft),  Average Daily Traffic: 9,500 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,448 (year 2042),  Features Intersected: UP RR, DELL AVE,  Facility Carried by Structure: SAN TOMAS EXPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 20.9m (68.6ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Critical Feature Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0108,  Location: AT SAN TOMAS AQUINO CR (Lat: 37.286836,  Lng: -121.961106),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 2,750 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,164 (year 2044),  Design Load: HS 20,  Features Intersected: SAN TOMAS AQUINO CREEK,  Facility Carried by Structure: CAMPBELL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 30.8m (101.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.8m (35.4ft),  Curb or Sidewalk Widths: Left: 7.0m (23.0ft),  Right: 5.2m (17.1ft),  Curb-To-Curb Width: 30.9m (101.4ft),  Out-to-Out Width: 43.1m (141.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 99.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0136,  Location: AT SAN TOMAS EXPWY (Lat: 37.294008,  Lng: -121.961150),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 3,000 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,219 (year 2044),  Design Load: HS 20,  Features Intersected: SAN TOMAS AQUINO CREEK,  Facility Carried by Structure: HAMILTON AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 41.7m (136.8ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 5.0m (16.4ft),  Right: 5.0m (16.4ft),  Curb-To-Curb Width: 41.7m (136.8ft),  Out-to-Out Width: 51.7m (169.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0149,  Location: NEAR SH 17 (Lat: 37.286997,  Lng: -121.938358),  Route carried "on" structure: City street ,  Year Built: 1940,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 23,509 (year 2013),  Truck Traffic: 2%,  Average Future Daily Traffic: 30,662 (year 2039),  Design Load: H 15,  Features Intersected: LOS GATOS CREEK,  Facility Carried by Structure: CAMPBELL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0157,  Location: NEAR BASCOM AVE (Lat: 37.294153,  Lng: -121.933258),  Route carried "on" structure: City street ,  Year Built: 1960,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 56,709 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 109,045 (year 2039),  Design Load: HS 20,  Features Intersected: LOS GATOS CREEK,  Facility Carried by Structure: HAMILTON AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 9,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.4m (103.0ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 31.4m (103.0ft),  Out-to-Out Width: 35.1m (115.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0282,  Location: BUDD AVE (Lat: 37.279406,  Lng: -121.963308),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,704 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,750 (year 2037),  Features Intersected: SAN TOMAS AQUINO CREEK,  Facility Carried by Structure: VIRGINIA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.1m (13.5ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 14.2m (46.6ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 37C0283,  Location: FENIAN DR (Lat: 37.277331,  Lng: -121.976625),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 7,000 (year 2010),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,724 (year 2036),  Features Intersected: SAN TOMAS AQUINO CREEK,  Facility Carried by Structure: HARRIET AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.8m (12.5ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: 37C0284,  Location: NEAR HARRIET AVE (Lat: 37.276511,  Lng: -121.977625),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 5,009 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,525 (year 2037),  Features Intersected: SAN TOMAS AQUINO CREEK,  Facility Carried by Structure: MCCOY AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 37 0133,  Location: 04-SCL-017-11.80-CMB (Lat: 37.287058,  Lng: -121.936606),  Route carried "under" structure: City street C031,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 23,509 (year 2013),  Truck Traffic: 1%,  Features Intersected: CAMPBELL AVE,  Facility Carried by Structure: STATE ROUTE 17
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 37 0135,  Location: 04-SCL-017-12.22-CMB (Lat: 37.292514,  Lng: -121.937792),  Route carried "under" structure: State highway 17,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 151,200 (year 2017),  Truck Traffic: 7%,  Features Intersected: STATE ROUTE 17,  Facility Carried by Structure: UP RR
Minimum Vertical Clearance: 4.64m (15.22ft),  Kilometerpoint: 12.220,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 25.0m (82.0ft)

Find on map >>   Show street view

Structure Number: 37 0136,  Location: 04-SCL-017-12.34-CMB (Lat: 37.294236,  Lng: -121.938583),  Route carried "under" structure: State highway 17,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 184,800 (year 2017),  Truck Traffic: 4%,  Features Intersected: STATE ROUTE 17,  Facility Carried by Structure: HAMILTON AVE
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 12.340,  Lanes on structure: 7,  Lanes under structure: 8,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 37 0147,  Location: 04-SCL-017-10.50-CMB (Lat: 37.270458,  Lng: -121.947142),  Route carried "under" structure: City street ,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 62,140 (year 2014),  Truck Traffic: 7%,  Features Intersected: CAMDEN AVE,  Facility Carried by Structure: STATE ROUTE 17
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 9,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 36.3m (119.1ft)

Find on map >>   Show street view

Structure Number: 37 0535,  Location: 04-SCL-017-9.60 (Lat: 37.259675,  Lng: -121.953694),  Route carried "under" structure: Ramp State highway 85,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 20,400 (year 2013),  Truck Traffic: 2%,  Features Intersected: SR 17, S17-N&S85 CONNS,  Facility Carried by Structure: PEDESTRIAN WALKWAY
Minimum Vertical Clearance: 5.80m (19.03ft),  Kilometerpoint: 10.480,  Lanes under structure: 1,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 42.2m (138.5ft)

Find on map >>   Show street view

Structure Number: 37 0535,  Location: 04-SCL-017-9.60 (Lat: 37.259675,  Lng: -121.953694),  Route carried "under" structure: Ramp State highway 17,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 14,000 (year 2010),  Truck Traffic: 5%,  Features Intersected: SR 17, S17-N&S85 CONNS,  Facility Carried by Structure: PEDESTRIAN WALKWAY
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 9.800,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 42.2m (138.5ft)

Find on map >>   Show street view

Structure Number: 37 0535,  Location: 04-SCL-017-9.60 (Lat: 37.259675,  Lng: -121.953694),  Route carried "under" structure: State highway 17,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 139,700 (year 2017),  Truck Traffic: 7%,  Features Intersected: SR 17, S17-N&S85 CONNS,  Facility Carried by Structure: PEDESTRIAN WALKWAY
Minimum Vertical Clearance: 5.80m (19.03ft),  Kilometerpoint: 9.600,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 42.2m (138.5ft)

Find on map >>   Show street view

Structure Number: 37 0535,  Location: 04-SCL-017-9.60 (Lat: 37.259675,  Lng: -121.953694),  Route carried "under" structure: Ramp State highway 17,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 15,100 (year 2013),  Truck Traffic: 5%,  Features Intersected: SR 17, S17-N&S85 CONNS,  Facility Carried by Structure: PEDESTRIAN WALKWAY
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 9.810,  Lanes under structure: 1,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 42.2m (138.5ft)

Find on map >>   Show street view

Structure Number: 37 0603,  Location: 04-SCL-017-12.23-CMB (Lat: 37.292556,  Lng: -121.937889),  Route carried "under" structure: State highway 17,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 151,200 (year 2017),  Truck Traffic: 7%,  Features Intersected: STATE ROUTE 17,  Facility Carried by Structure: VTA LRT (2 TRACKS)
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 12.230,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 38.0m (124.7ft)

Find on map >>   Show street view

Structure Number: 37C0083,  Location: AT WINCHESTER BLVD (Lat: 37.273750,  Lng: -121.953206),  Route carried "under" structure: City street ,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2010),  Truck Traffic: 1%,  Features Intersected: WINCHESTER BLVD & UP RR,  Facility Carried by Structure: SAN TOMAS EXPWY
Minimum Vertical Clearance: 6.71m (22.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.2m (59.7ft)

Discuss Campbell, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.