Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Whittier, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 85ft / 25.6mTotal length
  • 824,944Total average daily traffic
  • 70,339Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Whittier
  • No street view available for this location

New bridges in Whittier, CA - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11940-1949
  • 21950-1959
  • 51960-1969
  • 12000-2009
Reconstructed bridges in Whittier, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 11970-1979
Average Bridge Daily Traffic in Whittier, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 75.0%Good
  • 25.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 75.0%Good
  • 25.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Very good
  • 33.3%Good
Find on map >>   Show street view

Structure Number: 53 0002,  Location: 07-LA-101-34.82-AGRH (Lat: 34.145797,  Lng: -118.757422),  Route carried "on" structure: US 101,  Year Built: 1949,  Year Reconstructed: 1973,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 160,000 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 193,146 (year 2038),  Design Load: HS 20,  Features Intersected: MEDEA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.820,  Lanes on structure: 10,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.0m (173.9ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 53.0m (173.9ft),  Out-to-Out Width: 54.3m (178.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 1501,  Location: 07-LA-405-46.74-LA (Lat: 34.264383,  Lng: -118.471911),  Route carried "on" structure: Interstate 405,  Year Built: 1963,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 209,000 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 270,154 (year 2038),  Design Load: HS 20,  Features Intersected: CHATSWORTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 46.740,  Lanes on structure: 12,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 4,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.0m (173.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 51.2m (168.0ft),  Out-to-Out Width: 53.3m (174.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 1509,  Location: 07-LA-605-R13.55-WIT (Lat: 33.993053,  Lng: -118.069092),  Route carried "on" structure: Interstate 605,  Year Built: 1964,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 264,000 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 268,410 (year 2040),  Design Load: HS 20,  Features Intersected: STATE ROUTE 72
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.550,  Lanes on structure: 12,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 6,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 42.6m (139.8ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 42.6m (139.8ft),  Out-to-Out Width: 45.1m (148.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C1636,  Location: 0.1MI E/O TIGRINA AVE (Lat: 33.928892,  Lng: -117.980344),  Route carried "on" structure: City street ,  Year Built: 1955,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 202 (year 2014),  Truck Traffic: 2%,  Average Future Daily Traffic: 202 (year 2042),  Features Intersected: LA MIRADA CRK,  Facility Carried by Structure: HEATHFIELD DR
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 53C2302,  Location: 07-LA-072-6.86-PRV (Lat: 33.995828,  Lng: -118.072819),  Route carried "on" structure: City street ,  Year Built: 1968,  Status: Open,  Structure Length: 11.49m (37.70ft),  Average Daily Traffic: 34,000 (year 2011),  Average Future Daily Traffic: 42,301 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SAN GABRIEL RIV,  Facility Carried by Structure: WHITTIER BLVD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 29.3m (96.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 0007,  Location: 07-LA-072-4.24-WIT (Lat: 33.967592,  Lng: -118.041172),  Route carried "under" structure: State highway 72,  Year Built: 1930,  Structure Length: 0. m,  Average Daily Traffic: 44,100 (year 2010),  Features Intersected: SR 72 (WHITTIER BLVD),  Facility Carried by Structure: BIKE TRAIL
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 4.240,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Slab,  Length of Maximum Span: 57.6m (189.0ft)

Find on map >>   Show street view

Structure Number: 53 1509,  Location: 07-LA-605-R13.55-WIT (Lat: 33.993053,  Lng: -118.069092),  Route carried "under" structure: State highway 72,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 40,000 (year 2012),  Truck Traffic: 4%,  Features Intersected: STATE ROUTE 72,  Facility Carried by Structure: INTERSTATE 605
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 6.660,  Lanes on structure: 12,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 18.6m (61.0ft)

Find on map >>   Show street view

Structure Number: 53C0455,  Location: 0.5MI N/O WHITTIER BLVD (Lat: 33.994133,  Lng: -118.059644),  Route carried "under" structure: City street L094,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 19,240 (year 2012),  Truck Traffic: 2%,  Features Intersected: NORWALK BLVD,  Facility Carried by Structure: WHITT GRNWY TR POC
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.000,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 53C2236,  Location: 50FT N/O WHITTIER BLVD (Lat: 33.967594,  Lng: -118.041169),  Route carried "under" structure: City street ,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 10,302 (year 2012),  Truck Traffic: 2%,  Features Intersected: PICKERING AVE,  Facility Carried by Structure: WHITT GRNWY TR POC
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Truss - Thru,  Length of Maximum Span: 42.3m (138.8ft)

Find on map >>   Show street view

Structure Number: 53C2304,  Location: 0.1MI W/O ESPERANZA AVE (Lat: 33.994861,  Lng: -118.071556),  Route carried "under" structure: City street ,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 44,100 (year 2010),  Truck Traffic: 5%,  Features Intersected: WHITTIER BLVD,  Facility Carried by Structure: UPRR
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Slab,  Length of Maximum Span: 26.1m (85.6ft)

Discuss Whittier, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.