Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Manchester, Virginia (VA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 125ft / 37.8mTotal length
  • $306,000Total costs
  • 585,714Total average daily traffic
  • 16,058Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Manchester
  • No street view available for this location

New bridges in Manchester, VA - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 81970-1979
  • 61980-1989
  • 41990-1999
  • 12010-2019
Average Bridge Daily Traffic in Manchester, VA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 62.5%Good
  • 37.5%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 37.5%Good
  • 62.5%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.0%Good
  • 75.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 16.7%Satisfactory
  • 66.7%Fair
  • 16.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 80.0%Satisfactory
  • 20.0%Fair
Find on map >>   Show street view

Structure Number: 5032,  Location: 2.24 Fr 653 & 0.61 To 60 (Lat: 37.487825,  Lng: -77.567203),  Route carried "on" structure: State highway 76,  Year Built: 1988,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 41,820 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 49,425 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: RTE 2510 (REDBRIDGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.670,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.5m (96.8ft),  Curb-To-Curb Width: 23.3m (76.4ft),  Out-to-Out Width: 24.3m (79.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5115,  Location: 0.74 Fr 60 & 0.61 To 360 (Lat: 37.488906,  Lng: -77.519789),  Route carried "on" structure: State highway 150,  Year Built: 1968,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 68,600 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 96,040 (year 2040),  Design Load: H 20,  Features Intersected: POCOSHAM CREEK,  Facility Carried by Structure: CHIPPENHAM PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.277,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 5116,  Location: 0.84 Fr 686 & 1.54 to 360 (Lat: 37.501700,  Lng: -77.525222),  Route carried "on" structure: State highway 150,  Year Built: 1971,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 34,300 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 48,020 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 60
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.780,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.4m (63.6ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.6m (149.6ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 58.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5118,  Location: 0.84 Fr 686 & 1.54 To 360 (Lat: 37.501769,  Lng: -77.524892),  Route carried "on" structure: State highway 150,  Year Built: 1971,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 34,300 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 48,020 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 60
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.780,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.4m (63.6ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.6m (149.6ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 512,  Location: 1.48 Fr 60 &1.45 To 651 (Lat: 37.478936,  Lng: -77.515572),  Route carried "on" structure: State highway 150,  Year Built: 1971,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 35,089 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 49,126 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 360 (HULL ST.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.451,  Lanes on structure: 3,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.5m (136.2ft),  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 60.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5122,  Location: 1.48 Fr 60 & 1.45 To 651 (Lat: 37.479019,  Lng: -77.515264),  Route carried "on" structure: State highway 150,  Year Built: 1971,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 35,089 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 49,126 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 360 (HULL ST.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.451,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.5m (136.2ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 58.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5283,  Location: 0.10 FR 649 & 0.58 TO 650 (Lat: 37.463206,  Lng: -77.530703),  Route carried "on" structure: County highway 647,  Year Built: 1980,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 11,501 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 15,023 (year 2040),  Design Load: H 20,  Features Intersected: POCOSHOCK CREEK,  Facility Carried by Structure: WALMSLEY BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.562,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 529,  Location: 0.14 Fr 758 & 1.01 To 643 (Lat: 37.443397,  Lng: -77.522264),  Route carried "on" structure: County highway 651,  Year Built: 1980,  Status: Open,  Structure Length: 3.74m (12.27ft),  Average Daily Traffic: 6,989 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,688 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: FALLING CREEK,  Facility Carried by Structure: BELMONT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.677,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.75m (12.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $170,000,  Roadway Improvement Cost: $85,000,  Total Project Cost: $306,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 5352,  Location: 0.45 Fr 647 & 0.18 To 360 (Lat: 37.475008,  Lng: -77.520369),  Route carried "on" structure: County highway 1668,  Year Built: 1986,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 2,999 (year 2016),  Average Future Daily Traffic: 3,321 (year 2040),  Design Load: H 20,  Features Intersected: UNNAMED TRIBUTARY,  Facility Carried by Structure: GOODES BRIDGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.734,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.5m (4.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 24675,  Location: 0.76 Fr 663 & 0.24 To 60 (Lat: 37.494861,  Lng: -77.539586),  Route carried "on" structure: County highway 733,  Year Built: 1980,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 3,682 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,050 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: POCOSHAM CREEK,  Facility Carried by Structure: RUTHERS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.282,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 25376,  Location: 1.04 TO 60 & 0.69 FR 76 (Lat: 37.516361,  Lng: -77.528297),  Route carried "on" structure: State highway 150,  Year Built: 1999,  Status: Open,  Structure Length: 2.97m (9.74ft),  Average Daily Traffic: 34,300 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 48,020 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 686 (JAHNKE ROAD),  Facility Carried by Structure: SBL CHIPPENHAM PKW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.139,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.5m (93.5ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Inventory Rating: 71.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 25377,  Location: 1.04 FR 60 & 0.69 to 76 (Lat: 37.516356,  Lng: -77.528092),  Route carried "on" structure: State highway 150,  Year Built: 1999,  Status: Open,  Structure Length: 2.97m (9.74ft),  Average Daily Traffic: 34,300 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 48,020 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 686 (JAHNKE ROAD),  Facility Carried by Structure: NBL CHIPPENHAM PKW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.139,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.5m (93.5ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 85.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 29388,  Location: 0.1frAutMstWy&0.1toDorton (Lat: 37.451300,  Lng: -77.520797),  Route carried "on" structure: County highway 7440,  Year Built: 2010,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 25 (year 2010),  Average Future Daily Traffic: 35 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: BRANCH OF FALLING CREEK,  Facility Carried by Structure: AUTUMN MIST DRIVE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 5032,  Location: 2.24 Fr 653 & 0.61 To 60 (Lat: 37.487825,  Lng: -77.567203),  Route carried "under" structure: County highway 2510,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 720 (year 2019),  Features Intersected: RTE 2510 (REDBRIDGE ROAD,  Facility Carried by Structure: ROUTE 76
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 1.368,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.5m (96.8ft)

Find on map >>   Show street view

Structure Number: 5116,  Location: 0.84 Fr 686 & 1.54 to 360 (Lat: 37.501700,  Lng: -77.525222),  Route carried "under" structure: US 60,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 57,000 (year 2020),  Truck Traffic: 2%,  Features Intersected: ROUTE 60,  Facility Carried by Structure: ROUTE 150 EBL
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 296.716,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.6m (149.6ft)

Find on map >>   Show street view

Structure Number: 5118,  Location: 0.84 Fr 686 & 1.54 To 360 (Lat: 37.501769,  Lng: -77.524892),  Route carried "under" structure: US 60,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 57,000 (year 2020),  Truck Traffic: 2%,  Features Intersected: ROUTE 60,  Facility Carried by Structure: ROUTE 150 NBL
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 296.700,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.6m (149.6ft)

Find on map >>   Show street view

Structure Number: 512,  Location: 1.48 Fr 60 &1.45 To 651 (Lat: 37.478936,  Lng: -77.515572),  Route carried "under" structure: US 360,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 51,000 (year 2020),  Truck Traffic: 7%,  Features Intersected: ROUTE 360 (HULL ST.),  Facility Carried by Structure: ROUTE 150 SBL
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 216.330,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 5122,  Location: 1.48 Fr 60 & 1.45 To 651 (Lat: 37.479019,  Lng: -77.515264),  Route carried "under" structure: US 360,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 51,000 (year 2020),  Truck Traffic: 7%,  Features Intersected: ROUTE 360 (HULL ST.),  Facility Carried by Structure: ROUTE 150 NBL
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 216.346,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 25376,  Location: 1.04 TO 60 & 0.69 FR 76 (Lat: 37.516361,  Lng: -77.528297),  Route carried "under" structure: County highway 686,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2020),  Truck Traffic: 1%,  Features Intersected: ROUTE 686 (JAHNKE ROAD),  Facility Carried by Structure: SBL CHIPPENHAM PKW
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 2.944,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.5m (93.5ft)

Find on map >>   Show street view

Structure Number: 25377,  Location: 1.04 FR 60 & 0.69 to 76 (Lat: 37.516356,  Lng: -77.528092),  Route carried "under" structure: County highway 686,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2020),  Truck Traffic: 1%,  Features Intersected: ROUTE 686 (JAHNKE ROAD),  Facility Carried by Structure: NBL CHIPPENHAM PKW
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 3.009,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.5m (93.5ft)

Discuss Manchester, Virginia (VA) on our hugely popular Virginia forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.