Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Grass Valley, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 33Number of bridges
  • 361ft / 110mTotal length
  • $1,433,000Total costs
  • 526,625Total average daily traffic
  • 17,059Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Grass Valley
  • No street view available for this location

New bridges in Grass Valley, CA - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 251960-1969
  • 31970-1979
  • 21980-1989
  • 11990-1999
  • 12000-2009
Reconstructed bridges in Grass Valley, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 01950-1959
  • 01960-1969
  • 21970-1979
  • 21980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Grass Valley, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 75.0%Good
  • 6.3%Satisfactory
  • 12.5%Fair
  • 6.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 62.5%Good
  • 25.0%Satisfactory
  • 6.3%Fair
  • 6.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 87.5%Good
  • 6.3%Fair
  • 6.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 28.6%Very good
  • 57.1%Good
  • 14.3%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 75.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 17 0007,  Location: 03-NEV-049-R21.86 (Lat: 39.296475,  Lng: -121.091325),  Route carried "on" structure: State highway 49,  Year Built: 1994,  Status: Open,  Structure Length: 31.27m (102.59ft),  Average Daily Traffic: 3,850 (year 2009),  Average Future Daily Traffic: 9,367 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SOUTH YUBA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.860,  Lanes on structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 13,  Length of Maximum Span: 45.7m (149.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 17 0032,  Location: 03-NEV-174-10.17-GVY (Lat: 39.217903,  Lng: -121.060175),  Route carried "on" structure: State highway 174,  Year Built: 1969,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 8,000 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 13,262 (year 2036),  Features Intersected: WOLF CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.170,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018
Find on map >>   Show street view

Structure Number: 17 0045,  Location: 03-NEV-080-13.22 (Lat: 39.324542,  Lng: -120.225639),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 1,000 (year 2000),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,094 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 80,  Facility Carried by Structure: DONNER PASS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.9m (114.5ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 17 0048,  Location: 03-NEV-020-R14.80 (Lat: 39.235400,  Lng: -121.037022),  Route carried "on" structure: County highway ,  Year Built: 1969,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 26,000 (year 2010),  Truck Traffic: 12%,  Average Future Daily Traffic: 30,809 (year 2038),  Design Load: HS 20,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: BRUNSWICK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.0m (91.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 14.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 17 0049,  Location: 03-NEV-020-R12.24-GVY (Lat: 39.209547,  Lng: -121.068497),  Route carried "on" structure: State highway 20,  Year Built: 1969,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 4.25m (13.94ft),  Average Daily Traffic: 8,200 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 31,222 (year 2042),  Design Load: HS 20,  Features Intersected: STATE ROUTE 49
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.240,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.5m (136.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 25.8m (84.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 50.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 17 0051,  Location: 03-NEV-020-R13.04-GVY (Lat: 39.217697,  Lng: -121.059369),  Route carried "on" structure: State highway 20,  Year Built: 1969,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 34,500 (year 2009),  Average Future Daily Traffic: 81,556 (year 2038),  Design Load: HS 20,  Features Intersected: BANK STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.040,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 17 0052,  Location: 03-NEV-020-R13.11-GVY (Lat: 39.218567,  Lng: -121.058642),  Route carried "on" structure: State highway 20,  Year Built: 1969,  Status: Open,  Structure Length: 4.24m (13.91ft),  Average Daily Traffic: 34,500 (year 2009),  Average Future Daily Traffic: 81,555 (year 2038),  Design Load: HS 20,  Features Intersected: BENNETT STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.110,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 27.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 17 007,  Location: 03-NEV-080-R58.84 (Lat: 39.317172,  Lng: -120.614428),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 700 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,636 (year 2041),  Design Load: HS 20,  Features Intersected: INTERSTATE 80,  Facility Carried by Structure: LAKE VALLEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 17 0077,  Location: 03-NEV-020-R15.41 (Lat: 39.243167,  Lng: -121.031511),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Open,  Structure Length: 9.39m (30.81ft),  Average Daily Traffic: 7,500 (year 2010),  Truck Traffic: 9%,  Average Future Daily Traffic: 10,408 (year 2042),  Design Load: HS 20,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: BANNER LAVA CAP RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 17 0079,  Location: 03-NEV-020-R13.61-GVY (Lat: 39.222542,  Lng: -121.051028),  Route carried "on" structure: State highway 20,  Year Built: 1969,  Status: Open,  Structure Length: 2.71m (8.89ft),  Average Daily Traffic: 47,000 (year 2009),  Average Future Daily Traffic: 78,834 (year 2038),  Design Load: HS 20,  Features Intersected: IDAHO-MARYLAND ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.610,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.9m (88.3ft),  Skew: 35 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 26.9m (88.3ft),  Out-to-Out Width: 28.1m (92.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 17 0079S,  Location: 03-NEV-020-R13.61-GVY (Lat: 39.222511,  Lng: -121.050769),  Route carried "on" structure: Bypass State highway 20,  Year Built: 1969,  Status: Open,  Structure Length: 5.09m (16.70ft),  Average Daily Traffic: 1,200 (year 2010),  Truck Traffic: 9%,  Average Future Daily Traffic: 2,567 (year 2038),  Design Load: HS 20,  Features Intersected: IDAHO-MARYLAND ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.610,  Lanes on structure: 1,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 17 008,  Location: 03-NEV-049-R13.66-GVY (Lat: 39.200214,  Lng: -121.059650),  Route carried "on" structure: City street ,  Year Built: 1969,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 12,000 (year 2010),  Truck Traffic: 2%,  Average Future Daily Traffic: 17,459 (year 2038),  Design Load: HS 20,  Features Intersected: STATE ROUTE 49,  Facility Carried by Structure: S. AUBURN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.8m (78.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 17 0081,  Location: 03-NEV-020-R14.26 (Lat: 39.229506,  Lng: -121.043258),  Route carried "on" structure: County highway ,  Year Built: 1969,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 28,000 (year 2010),  Truck Traffic: 9%,  Average Future Daily Traffic: 33,303 (year 2042),  Design Load: HL 93,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: DORSEY DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 22.5m (73.8ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.1m (88.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 22.5m (73.8ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 17 0083,  Location: 03-NEV-020-R12.16-GVY (Lat: 39.209697,  Lng: -121.069922),  Route carried "on" structure: State highway 20,  Year Built: 1969,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 3.25m (10.66ft),  Average Daily Traffic: 8,200 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 33,303 (year 2042),  Design Load: HS 20,  Features Intersected: MILL STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.160,  Lanes on structure: 6,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 31.7m (104.0ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 17 0093,  Location: 03-NEV-020-R13.44-GVY (Lat: 39.220628,  Lng: -121.053400),  Route carried "on" structure: State highway 20,  Year Built: 1969,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 47,000 (year 2009),  Average Future Daily Traffic: 81,556 (year 2038),  Features Intersected: WOLF CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.440,  Lanes on structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 33 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 17 0095,  Location: 03-NEV-020-R11.83-GVY (Lat: 39.209975,  Lng: -121.076197),  Route carried "on" structure: City street ,  Year Built: 1984,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 5,500 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,570 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: BRIGHTON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.6m (152.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 17C0024,  Location: 2.0 MI S TYLER-FOOTE (Lat: 39.327492,  Lng: -121.046575),  Route carried "on" structure: County highway ,  Year Built: 1895,  Year Reconstructed: 1951,  Status: Posted for load,  Structure Length: 5.85m (19.19ft),  Average Daily Traffic: 71 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 109 (year 2041),  Features Intersected: SOUTH YUBA RIVER,  Facility Carried by Structure: PURDON ROAD
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 44.2m (145.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 3.4m (11.2ft),  Out-to-Out Width: 4.0m (13.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Poor,  Channel: Very good,  Operating Rating: 4.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 5.85m (19.19ft),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Critical Feature Inspection Date: July 2021,  Bridge Improvement Cost: $540,000,  Roadway Improvement Cost: $108,000,  Total Project Cost: $908,000 ( Estimate for 2017),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 17C0025,  Location: 200'S IDAHO MARYLAND RD (Lat: 39.222853,  Lng: -121.049411),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 882 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,091 (year 2041),  Features Intersected: WOLF CREEK,  Facility Carried by Structure: RAIL ROAD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 17C0041,  Location: BTWN SR20 & SACRAMENTO ST (Lat: 39.262025,  Lng: -121.016456),  Route carried "on" structure: City street ,  Year Built: 1967,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 8,630 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,761 (year 2041),  Design Load: HS 20,  Features Intersected: DEER CREEK,  Facility Carried by Structure: BROAD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 50.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.77m (5.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $313,000,  Roadway Improvement Cost: $62,000,  Total Project Cost: $525,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 17C0049,  Location: BTWN E MAIN ST & SR 20 (Lat: 39.219269,  Lng: -121.058894),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 11,992 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,206 (year 2041),  Features Intersected: WOLF CREEK,  Facility Carried by Structure: BENNETT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 17 0048,  Location: 03-NEV-020-R14.80 (Lat: 39.235400,  Lng: -121.037022),  Route carried "under" structure: State highway 20,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 33,500 (year 2009),  Truck Traffic: 6%,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: BRUNSWICK ROAD
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 14.800,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 17 0049,  Location: 03-NEV-020-R12.24-GVY (Lat: 39.209547,  Lng: -121.068497),  Route carried "under" structure: State highway 49,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2009),  Truck Traffic: 4%,  Features Intersected: STATE ROUTE 49,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 14.460,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 17 005,  Location: 03-NEV-020-R12.85-GVY (Lat: 39.215722,  Lng: -121.061878),  Route carried "under" structure: State highway 174,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2010),  Truck Traffic: 6%,  Features Intersected: SR 174 (COLFAX),AUBURN,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 10.170,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 17 005,  Location: 03-NEV-020-R12.85-GVY (Lat: 39.215722,  Lng: -121.061878),  Route carried "under" structure: City street Y110,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 12,000 (year 2010),  Truck Traffic: 1%,  Features Intersected: SR 174 (COLFAX),AUBURN,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 17 0051,  Location: 03-NEV-020-R13.04-GVY (Lat: 39.217697,  Lng: -121.059369),  Route carried "under" structure: City street ,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 4,500 (year 2010),  Truck Traffic: 1%,  Features Intersected: BANK STREET,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 17 0052,  Location: 03-NEV-020-R13.11-GVY (Lat: 39.218567,  Lng: -121.058642),  Route carried "under" structure: City street ,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 4,500 (year 2010),  Truck Traffic: 1%,  Features Intersected: BENNETT STREET,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 17 0077,  Location: 03-NEV-020-R15.41 (Lat: 39.243167,  Lng: -121.031511),  Route carried "under" structure: State highway 20,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 33,500 (year 2009),  Truck Traffic: 6%,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: BANNER LAVA CAP RD
Minimum Vertical Clearance: 15.06m (49.41ft),  Kilometerpoint: 15.410,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.7m (94.2ft)

Find on map >>   Show street view

Structure Number: 17 0079,  Location: 03-NEV-020-R13.61-GVY (Lat: 39.222542,  Lng: -121.051028),  Route carried "under" structure: City street ,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2010),  Truck Traffic: 1%,  Features Intersected: IDAHO-MARYLAND ROAD,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 17 0079S,  Location: 03-NEV-020-R13.61-GVY (Lat: 39.222511,  Lng: -121.050769),  Route carried "under" structure: City street ,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2010),  Truck Traffic: 1%,  Features Intersected: IDAHO-MARYLAND ROAD,  Facility Carried by Structure: IDAHO-MARYLAND-E20
Minimum Vertical Clearance: 7.44m (24.41ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 17 008,  Location: 03-NEV-049-R13.66-GVY (Lat: 39.200214,  Lng: -121.059650),  Route carried "under" structure: State highway 49,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2009),  Truck Traffic: 4%,  Features Intersected: STATE ROUTE 49,  Facility Carried by Structure: S. AUBURN STREET
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 13.660,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 23.8m (78.1ft)

Find on map >>   Show street view

Structure Number: 17 0081,  Location: 03-NEV-020-R14.26 (Lat: 39.229506,  Lng: -121.043258),  Route carried "under" structure: State highway 20,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 36,500 (year 2009),  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: DORSEY DR
Minimum Vertical Clearance: 4.41m (14.47ft),  Kilometerpoint: 14.260,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 17 0083,  Location: 03-NEV-020-R12.16-GVY (Lat: 39.209697,  Lng: -121.069922),  Route carried "under" structure: City street ,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 7,200 (year 2010),  Truck Traffic: 1%,  Features Intersected: MILL STREET,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 17 0095,  Location: 03-NEV-020-R11.83-GVY (Lat: 39.209975,  Lng: -121.076197),  Route carried "under" structure: State highway 20,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 8,200 (year 2009),  Truck Traffic: 6%,  Features Intersected: STATE ROUTE 20,  Facility Carried by Structure: BRIGHTON ST
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 11.830,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 46.6m (152.9ft)